| Literature DB >> 33783597 |
Justyna Kutyba1, Elżbieta Gos2, Wiesław Wiktor Jędrzejczak2, Danuta Raj-Koziak2, Lucyna Karpiesz2, Iwona Niedziałek2, Henryk Skarżyński2, Piotr Henryk Skarżyński2,3,4.
Abstract
BACKGROUND: The World Health Organization reports that the number of tinnitus sufferers is increasing year on year. Given the common use of mobile devices and the availability of applications designed to support patients in tinnitus therapy and reduce tinnitus severity, patients seeking help are likely to try this form of support. The aim of this study was to evaluate the effectiveness of a mobile application in tinnitus sound therapy, in this case ReSound Tinnitus Relief™.Entities:
Keywords: Mobile applications; Sound therapy; Tinnitus; telemedicine
Mesh:
Year: 2021 PMID: 33783597 PMCID: PMC8897355 DOI: 10.1007/s00405-021-06767-9
Source DB: PubMed Journal: Eur Arch Otorhinolaryngol ISSN: 0937-4477 Impact factor: 2.503
Inclusion and exclusion criteria for subjects
| Inclusion criteria | Exclusion criteria |
|---|---|
- Adults - Annoying, continuous tinnitus - Subjective tinnitus - Physically and mentally fit to the extent that they are able to fill in the questionnaires themselves - Persons who have a mobile phone with android or ios | - Children and people under 18 years of age - Intermittent tinnitus - Objective tinnitus - Severe or profound hearing loss - No device enabling the use of the application - Disability preventing them from completing the questionnaires themselves |
Criteria for selecting a tested application
| Inclusion criteria | Exclusion criteria |
|---|---|
- Free of charge - In Polish - Using elements of sound therapy - Enables patients to have more options than a conventional sound generator - Supported by phones with Android or IOS systems | - Chargeable - In a language other than Polish - Mechanism of action not based on sound therapy - Requiring a special device (other than a mobile phone) - Special software requirements |
Fig. 1Selection process of application
Descriptive statistics of the results of tinnitus severity measured with THI
| THI subscale | Period | Min | Max | M | SD | Q1 | Me | Q3 |
|---|---|---|---|---|---|---|---|---|
| Functional | Baseline | 2 | 44 | 24.35 | 10.65 | 16.50 | 26.00 | 32.00 |
| 3 month follow-up | 2 | 42 | 22.63 | 10.61 | 12.50 | 23.00 | 30.00 | |
| 6 month follow-up | 0 | 38 | 16.77 | 9.95 | 6.50 | 18.00 | 22.00 | |
| Emotional | Baseline | 0 | 36 | 18.21 | 8.68 | 12.00 | 17.00 | 26.00 |
| 3 month follow-up | 0 | 36 | 15.65 | 9.10 | 8.50 | 16.00 | 22.00 | |
| 6 month follow-up | 0 | 26 | 10.77 | 7.47 | 4.00 | 12.00 | 17.50 | |
| Catastrophic | Baseline | 2 | 20 | 11.85 | 4.41 | 10.00 | 12.00 | 14.00 |
| 3 month follow-up | 0 | 20 | 9.63 | 4.94 | 6.00 | 10.00 | 13.50 | |
| 6 month follow-up | 0 | 20 | 7.42 | 4.34 | 4.00 | 7.00 | 10.00 | |
| THI global | Baseline | 6 | 100 | 54.40 | 22.09 | 38.25 | 55.00 | 71.50 |
| 3 month follow-up | 10 | 96 | 47.92 | 22.73 | 30.00 | 48.00 | 67.50 | |
| 6 month follow-up | 0 | 72 | 34.96 | 19.84 | 16.50 | 36.00 | 50.00 |
M mean, SD standard deviation, Q1 lower quartile, Me median, Q3 upper quartile
Descriptive statistics of the results of tinnitus severity measured with TFI
| TFI subscale | Period | Min | Max | M | SD | Q1 | Me | Q3 |
|---|---|---|---|---|---|---|---|---|
| Intrusiveness | Baseline | 20.00 | 100.00 | 64.74 | 21.53 | 50.83 | 68.33 | 80.00 |
| 3 month follow-up | 0.00 | 100.00 | 58.40 | 22.87 | 40.00 | 63.33 | 76.67 | |
| 6 month follow-up | 10.00 | 86.67 | 49.10 | 22.20 | 26.67 | 50.00 | 69.17 | |
| Sense of Control | Baseline | 6.67 | 100.00 | 48.08 | 26.86 | 23.33 | 48.33 | 70.00 |
| 3 month follow-up | 0.00 | 90.00 | 40.64 | 23.14 | 20.00 | 38.33 | 56.67 | |
| 6 month follow-up | 0.00 | 86.67 | 35.71 | 21.98 | 13.33 | 36.67 | 56.67 | |
| Cognition | Baseline | 0.00 | 100.00 | 44.17 | 27.30 | 20.83 | 46.67 | 60.00 |
| 3 month follow-up | 0.00 | 90.00 | 40.45 | 23.90 | 20.00 | 40.00 | 56.67 | |
| 6 month follow-up | 0.00 | 80.00 | 34.55 | 22.56 | 16.67 | 30.00 | 50.00 | |
| Sleep | Baseline | 3.33 | 100.00 | 55.32 | 30.13 | 30.83 | 51.67 | 80.00 |
| 3 month follow-up | 0.00 | 100.00 | 51.03 | 27.61 | 30.83 | 48.33 | 73.33 | |
| 6 month follow-up | 0.00 | 90.00 | 41.99 | 23.86 | 26.67 | 38.33 | 63.33 | |
| Auditory | Baseline | 0.00 | 100.00 | 49.68 | 27.80 | 26.67 | 58.33 | 70.00 |
| 3 month follow-up | 0.00 | 100.00 | 43.91 | 24.66 | 26.67 | 50.00 | 56.67 | |
| 6 month follow-up | 0.00 | 86.67 | 36.28 | 22.24 | 20.83 | 33.33 | 50.00 | |
| Relaxation | Baseline | 6.67 | 100.00 | 55.51 | 28.39 | 33.33 | 56.67 | 75.00 |
| 3 month follow-up | 0.00 | 100.00 | 49.68 | 26.59 | 30.00 | 45.00 | 75.00 | |
| 6 month follow-up | 0.00 | 83.33 | 39.81 | 24.55 | 20.00 | 38.33 | 60.00 | |
| Quality of Life | Baseline | 0.00 | 100.00 | 45.67 | 28.66 | 23.13 | 43.75 | 70.00 |
| 3 month follow-up | 0.00 | 100.00 | 39.81 | 27.29 | 15.00 | 41.25 | 60.00 | |
| 6 month follow-up | 0.00 | 80.00 | 29.52 | 23.38 | 10.00 | 30.00 | 44.38 | |
| Emotional | Baseline | 6.67 | 100.00 | 47.31 | 26.99 | 20.00 | 50.00 | 69.17 |
| 3 month follow-up | 0.00 | 96.67 | 36.03 | 26.56 | 14.67 | 30.00 | 60.00 | |
| 6 month follow-up | 0.00 | 80.00 | 29.62 | 23.84 | 7.50 | 23.33 | 46.67 | |
| Total | Baseline | 8.80 | 96.40 | 51.08 | 22.80 | 35.20 | 51.60 | 66.80 |
| 3 month follow-up | 0.80 | 95.60 | 44.78 | 20.91 | 29.50 | 42.60 | 60.20 | |
| 6 month follow-up | 1.20 | 72.80 | 36.77 | 18.99 | 20.70 | 35.00 | 47.80 |
M mean, SD standard deviation, Q1 lower quartile, Me median, Q3 upper quartile
Fig. 2Average results of THI and TFI global scores. The error bars are standard deviations. ***p < 0.001
Fig. 3Sounds listened to by participants