Literature DB >> 33782610

Monitoring deep-tissue oxygenation with a millimeter-scale ultrasonic implant.

Soner Sonmezoglu1, Jeffrey R Fineman2,3, Emin Maltepe2,3, Michel M Maharbiz4,5,6.   

Abstract

Vascular complications following solid organ transplantation may lead to graft ischemia, dysfunction or loss. Imaging approaches can provide intermittent assessments of graft perfusion, but require highly skilled practitioners and do not directly assess graft oxygenation. Existing systems for monitoring tissue oxygenation are limited by the need for wired connections, the inability to provide real-time data or operation restricted to surface tissues. Here, we present a minimally invasive system to monitor deep-tissue O2 that reports continuous real-time data from centimeter-scale depths in sheep and up to a 10-cm depth in ex vivo porcine tissue. The system is composed of a millimeter-sized, wireless, ultrasound-powered implantable luminescence O2 sensor and an external transceiver for bidirectional data transfer, enabling deep-tissue oxygenation monitoring for surgical or critical care indications.
© 2021. The Author(s), under exclusive licence to Springer Nature America, Inc.

Entities:  

Year:  2021        PMID: 33782610     DOI: 10.1038/s41587-021-00866-y

Source DB:  PubMed          Journal:  Nat Biotechnol        ISSN: 1087-0156            Impact factor:   54.908


  28 in total

1.  Waiting for organ transplantation. Institute of Medicine Committee on Organ Transplantation.

Authors:  R D Gibbons; D Meltzer; N Duan
Journal:  Science       Date:  2000-01-14       Impact factor: 47.728

Review 2.  Vascular complications following liver transplantation: A literature review of advances in 2015.

Authors:  Tullio Piardi; Martin Lhuaire; Onorina Bruno; Riccardo Memeo; Patrick Pessaux; Reza Kianmanesh; Daniele Sommacale
Journal:  World J Hepatol       Date:  2016-01-08

3.  Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust.

Authors:  Dongjin Seo; Ryan M Neely; Konlin Shen; Utkarsh Singhal; Elad Alon; Jan M Rabaey; Jose M Carmena; Michel M Maharbiz
Journal:  Neuron       Date:  2016-08-03       Impact factor: 17.173

4.  A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication.

Authors:  David K Piech; Benjamin C Johnson; Konlin Shen; M Meraj Ghanbari; Ka Yiu Li; Ryan M Neely; Joshua E Kay; Jose M Carmena; Michel M Maharbiz; Rikky Muller
Journal:  Nat Biomed Eng       Date:  2020-02-19       Impact factor: 25.671

5.  Fiber-optic probe for in vivo measurement of oxygen partial pressure.

Authors:  J I Peterson; R V Fitzgerald; D K Buckhold
Journal:  Anal Chem       Date:  1984-01       Impact factor: 6.986

6.  Quantitative tissue oxygen measurement in multiple organs using 19F MRI in a rat model.

Authors:  Siyuan Liu; Sameer J Shah; Lisa J Wilmes; John Feiner; Vikram D Kodibagkar; Michael F Wendland; Ralph P Mason; Nola Hylton; Harriet W Hopf; Mark D Rollins
Journal:  Magn Reson Med       Date:  2011-06-17       Impact factor: 4.668

7.  Electron paramagnetic resonance oxygen images correlate spatially and quantitatively with Oxylite oxygen measurements.

Authors:  Martyna Elas; Kang-Hyun Ahn; Adrian Parasca; Eugene D Barth; David Lee; Chad Haney; Howard J Halpern
Journal:  Clin Cancer Res       Date:  2006-07-15       Impact factor: 12.531

8.  Use of non-invasive NIRS during a vascular occlusion test to assess dynamic tissue O(2) saturation response.

Authors:  Hernando Gómez; Andrés Torres; Patricio Polanco; Hyung Kook Kim; Sven Zenker; Juan Carlos Puyana; Michael R Pinsky
Journal:  Intensive Care Med       Date:  2008-06-04       Impact factor: 17.440

9.  Wireless, battery-free optoelectronic systems as subdermal implants for local tissue oximetry.

Authors:  Hao Zhang; Philipp Gutruf; Kathleen Meacham; Michael C Montana; Xingyue Zhao; Antonio M Chiarelli; Abraham Vázquez-Guardado; Aaron Norris; Luyao Lu; Qinglei Guo; Chenkai Xu; Yixin Wu; Hangbo Zhao; Xin Ning; Wubin Bai; Irawati Kandela; Chad R Haney; Debashis Chanda; Robert W Gereau; John A Rogers
Journal:  Sci Adv       Date:  2019-03-08       Impact factor: 14.136

10.  Noninvasive optical quantification of cerebral venous oxygen saturation in humans.

Authors:  Jennifer M Lynch; Erin M Buckley; Peter J Schwab; David R Busch; Brian D Hanna; Mary E Putt; Daniel J Licht; Arjun G Yodh
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 5.482

View more
  9 in total

1.  Wireless implantable optical probe for continuous monitoring of oxygen saturation in flaps and organ grafts.

Authors:  Hexia Guo; Wubin Bai; Wei Ouyang; Yihan Liu; Changsheng Wu; Yameng Xu; Yang Weng; Hao Zang; Yiming Liu; Lauren Jacobson; Ziying Hu; Yihang Wang; Hany M Arafa; Quansan Yang; Di Lu; Shuo Li; Lin Zhang; Xun Xiao; Abraham Vázquez-Guardado; Joanna Ciatti; Elizabeth Dempsey; Nayereh Ghoreishi-Haack; Emily A Waters; Chad R Haney; Amanda M Westman; Matthew R MacEwan; Mitchell A Pet; John A Rogers
Journal:  Nat Commun       Date:  2022-05-30       Impact factor: 17.694

2.  Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics.

Authors:  Laura Becerra-Fajardo; Marc Oliver Krob; Jesus Minguillon; Camila Rodrigues; Christine Welsch; Marc Tudela-Pi; Albert Comerma; Filipe Oliveira Barroso; Andreas Schneider; Antoni Ivorra
Journal:  J Neuroeng Rehabil       Date:  2022-06-07       Impact factor: 5.208

3.  Flexible ultrasound-induced retinal stimulating piezo-arrays for biomimetic visual prostheses.

Authors:  Laiming Jiang; Gengxi Lu; Yushun Zeng; Yizhe Sun; Haochen Kang; James Burford; Chen Gong; Mark S Humayun; Yong Chen; Qifa Zhou
Journal:  Nat Commun       Date:  2022-07-04       Impact factor: 17.694

Review 4.  Injectable wireless microdevices: challenges and opportunities.

Authors:  Adam Khalifa; Sunwoo Lee; Alyosha Christopher Molnar; Sydney Cash
Journal:  Bioelectron Med       Date:  2021-12-23

5.  Augmented ultrasonography with implanted CMOS electronic motes.

Authors:  Yihan Zhang; Prashant Muthuraman; Victoria Andino-Pavlovsky; Ilke Uguz; Jeffrey Elloian; Kenneth L Shepard
Journal:  Nat Commun       Date:  2022-06-20       Impact factor: 17.694

Review 6.  Emerging Optoelectronic Devices Based on Microscale LEDs and Their Use as Implantable Biomedical Applications.

Authors:  Haijian Zhang; Yanxiu Peng; Nuohan Zhang; Jian Yang; Yongtian Wang; He Ding
Journal:  Micromachines (Basel)       Date:  2022-07-04       Impact factor: 3.523

7.  A wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves.

Authors:  Joshua C Chen; Peter Kan; Zhanghao Yu; Fatima Alrashdan; Roberto Garcia; Amanda Singer; C S Edwin Lai; Ben Avants; Scott Crosby; Zhongxi Li; Boshuo Wang; Michelle M Felicella; Ariadna Robledo; Angel V Peterchev; Stefan M Goetz; Jeffrey D Hartgerink; Sunil A Sheth; Kaiyuan Yang; Jacob T Robinson
Journal:  Nat Biomed Eng       Date:  2022-03-31       Impact factor: 29.234

8.  A Design of Analog Front-End with DBPSK Demodulator for Magnetic Field Wireless Network Sensors.

Authors:  S Ali Hosseini Asl; Behnam S Rikan; Arash Hejazi; YoungGun Pu; Hyungki Huh; Yeonjae Jung; Keum Cheol Hwang; Youngoo Yang; Kang-Yoon Lee
Journal:  Sensors (Basel)       Date:  2022-09-23       Impact factor: 3.847

9.  A flexible, stretchable system for simultaneous acoustic energy transfer and communication.

Authors:  Peng Jin; Ji Fu; Fengle Wang; Yingchao Zhang; Peng Wang; Xin Liu; Yang Jiao; Hangfei Li; Ying Chen; Yinji Ma; Xue Feng
Journal:  Sci Adv       Date:  2021-09-29       Impact factor: 14.136

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.