Literature DB >> 33773705

In situ Analytical Quality Control of chemotherapeutic solutions in infusion bags by Raman spectroscopy.

Alaa A Makki1, Suha Elderderi1, Victor Massot2, Renaud Respaud3, Hugh J Byrne4, Clovis Tauber5, Dominique Bertrand6, Elhadi Mohammed7, Igor Chourpa8, Franck Bonnier9.   

Abstract

Analytical Quality Control (AQC) in centralised preparation units of oncology centers is a common procedure relying on the identification and quantification of the prepared chemotherapeutic solutions for safe intravenous administration to patients. Although the use of Raman spectroscopy for AQC has gained much interest, in most applications it remains coupled to a flow injection analyser (FIA) requiring withdrawal of the solution for analysis. In addition to current needs for more rapid and cost-effective analysis, the risk of exposure of clinical staff to the toxic molecules during daily handling is a serious concern to address. Raman spectroscopic analysis, for instance by Confocal Raman Microscopy (CRM), could enable direct analysis (non-invasive) for AQC directly in infusion bags. In this study, 3 anticancer drugs, methotrexate (MTX), 5-fluorouracil (5-FU) and gemcitabine (GEM) have been selected to highlight the potential of CRM for withdrawal free analysis. Solutions corresponding to the clinical range of each drug were prepared in 5% glucose and data was collected from infusion bags placed under the Raman microscope. Firstly, 100% discrimination has been obtained by Partial Least Squares Discriminant Analysis (PLS-DA) confirming that the identification of drugs can be performed. Secondly, using Partial Least Squares Regression (PLSR), quantitative analysis was performed with mean % error of predicted concentrations of respectively 3.31%, 5.54% and 8.60% for MTX, 5-FU and GEM. These results are in accordance with the 15% acceptance criteria used for the current clinical standard technique, FIA, and the Limits of Detection for all drugs were determined to be substantially lower than the administered range, thus highlighting the potential of confocal Raman spectroscopy for direct analysis of chemotherapeutic solutions.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Analytical quality control; Chemotherapeutics; Confocal Raman micro-spectroscopy; Non-invasive analysis

Mesh:

Substances:

Year:  2021        PMID: 33773705     DOI: 10.1016/j.talanta.2021.122137

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Comparison of Vibrational Spectroscopic Techniques for Quantification of Water in Natural Deep Eutectic Solvents.

Authors:  Suha Elderderi; Pierre-Yves Sacré; Laura Wils; Igor Chourpa; Abdalla A Elbashir; Philippe Hubert; Hugh J Byrne; Leslie Boudesocque-Delaye; Eric Ziemons; Franck Bonnier
Journal:  Molecules       Date:  2022-07-27       Impact factor: 4.927

2.  Confocal Raman Spectroscopic Imaging for Evaluation of Distribution of Nano-Formulated Hydrophobic Active Cosmetic Ingredients in Hydrophilic Films.

Authors:  Louise Van Gheluwe; Emilie Munnier; Hichem Kichou; Kamilia Kemel; Frédéric Mahut; Marylène Vayer; Christophe Sinturel; Hugh J Byrne; Florent Yvergnaux; Igor Chourpa; Franck Bonnier
Journal:  Molecules       Date:  2021-12-08       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.