Literature DB >> 33751472

Global and regional cardiac dysfunction quantified by 18F-FDG PET scans can predict ventricular arrhythmia in patients with implantable cardioverter defibrillator.

Ran Jing1, Xiao-Xin Sun2, Wei Hua3, Liang Chen1, Sheng-Wen Yang1, Yi-Ran Hu1, Ni-Xiao Zhang1, Min-Si Cai1, Min Gu1, Hong-Xia Niu1, Shu Zhang1.   

Abstract

BACKGROUND: A low appropriate therapy rate indicates that a minority of patients will benefit from their implantable cardioverter defibrillator (ICD). Quantitative measurements from 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) may predict ventricular arrhythmia (VA) occurrence after ICD placement.
METHODS: We performed a prospective observational study and recruited patients who required ICD placement. Pre-procedure image scans were performed. Patients were followed up for VA occurrence. Associations between image results and VA were analyzed.
RESULTS: In 51 patients (33 males, 53.9 ± 17.2 years) analyzed, 17 (33.3%) developed VA. Compared with patients without VA, patients with VA had significantly larger values in scar area (17.7 ± 12.4% vs. 7.0 ± 7.9%), phase standard deviation (51.4° ± 14.0° vs. 34.0° ± 15.0°), bandwidth (172.9° ± 39.8° vs. 128.7° ± 49.9°), sum thickening score (STS, 29.5 ± 11.1 vs. 17.8 ± 13.2), and sum motion score (42.9 ± 11.5 vs. 33.0 ± 19.0). Cox regression analysis and receiver operating characteristic curve analysis showed that scar size, dyssynchrony, and STS were associated with VA occurrence (HR, 4.956, 95% CI 1.70-14.46).
CONCLUSION: Larger left ventricular scar burden, increased dyssynchrony, and higher STS quantified by 18F-FDG PET may indicate a higher VA incidence after ICD placement.

Entities:  

Keywords:  Left ventricular dyssynchrony; Myocardial metabolic imaging; Ventricular tachyarrhythmia; Wall thickening

Mesh:

Substances:

Year:  2021        PMID: 33751472     DOI: 10.1007/s12350-020-02515-4

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  3 in total

1.  Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 18F-FDG PET: comparison with cardiac MRI.

Authors:  Wolfgang M Schaefer; Claudia S A Lipke; Bernd Nowak; Hans-Juergen Kaiser; Patrick Reinartz; Arno Buecker; Gabriele A Krombach; Udalrich Buell; Harald P Kühl
Journal:  J Nucl Med       Date:  2004-01       Impact factor: 10.057

2.  Early Left Ventricular Involvement Detected by Cardiovascular Magnetic Resonance Feature Tracking in Arrhythmogenic Right Ventricular Cardiomyopathy: The Effects of Left Ventricular Late Gadolinium Enhancement and Right Ventricular Dysfunction.

Authors:  Xiuyu Chen; Lu Li; Huaibin Cheng; Yanyan Song; Keshan Ji; Lin Chen; Tongtong Han; Minjie Lu; Shihua Zhao
Journal:  J Am Heart Assoc       Date:  2019-08-23       Impact factor: 5.501

3.  Prognostic value of integrative analysis of electrical and mechanical dyssynchrony in patients with acute heart failure.

Authors:  Yanli Zhou; Zhuo He; Shengen Liao; Yanyun Liu; Li Zhang; Xu Zhu; Iokfai Cheang; Haifeng Zhang; Wenming Yao; Xinli Li; Weihua Zhou
Journal:  J Nucl Cardiol       Date:  2020-11-04       Impact factor: 5.952

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.