Literature DB >> 33751297

Immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study.

Afarin Arghami1, David Simmons1, Jeanne St Germain1, Pooja Maney2.   

Abstract

BACKGROUND: Existing research on marginal bone stability around hydroxyapatite (HA)-coated implants often lacks adequate long-term follow-up. The purpose of this randomized prospective study was to evaluate the 7-year outcome of patients with immediate and early loaded single-tooth restorations supported by implants with plasma-sprayed, partially HA-coated surfaces. Forty-two patients in need of 50 single implants were treated in in the Postgraduate Periodontics Clinic of Louisiana State University School of Dentistry. Implants were randomly divided into 2 groups: Group A was immediately loaded, and Group B was early loaded. Continuous follow-up with periodic maintenance care and radiographic evaluations was performed. The primary outcome of interest was implant survival, characterized using the Kaplan-Meier method. Secondary study outcome consisted of peri-implant crestal bone level changes. Data on age, sex, bone quality, implant location, length and diameter, and prior augmentation of the site were collected. Multiple regression analyses were conducted to determine whether the independent variables were associated with bone loss.
RESULTS: One implant failed to maintain stability and was removed at 3 weeks. Thirty-four patients (14 males, 20 females with a total of 42 implants) completed the 7-year follow-up visit. Average age of evaluable patients was 52 in Group A and 55 in Group B. No significant difference was observed regarding sex and age distribution between the 2 groups. No significant difference was detected in the distribution of implant locations, types of bone, implant length, implant diameter, and augmentation status of the bone between the 2 groups. After 7 years of functioning for the 42 implants examined, implant survival rate was 100% for Group A and 95.5% for Group B. The results from this study of 50 implants showed that HA-coated Zimmer Tapered Screw-Vent Implants were clinically effective, with an overall cumulative 7-year survival rate of 98.0%. When comparing radiographic bone levels between 2-year and 7-year follow-ups, no significant differences in bone loss were found between Group A and Group B.
CONCLUSIONS: After 7 years in function, implants partially coated with plasma-sprayed and hydrothermally treated HA were clinically predictable when restored in occlusion immediately after or 3 weeks after implant placement.

Entities:  

Keywords:  Dental implants; HA coated; Survival

Year:  2021        PMID: 33751297      PMCID: PMC7943663          DOI: 10.1186/s40729-021-00299-x

Source DB:  PubMed          Journal:  Int J Implant Dent        ISSN: 2198-4034


  29 in total

Review 1.  Mechanisms of endosseous integration.

Authors:  J E Davies
Journal:  Int J Prosthodont       Date:  1998 Sep-Oct       Impact factor: 1.681

2.  Evaluation of hydroxylapatite-coated titanium dental implants in dogs.

Authors:  M S Block; J N Kent; J F Kay
Journal:  J Oral Maxillofac Surg       Date:  1987-07       Impact factor: 1.895

3.  Survival of hydroxyapatite-coated implants: a meta-analytic review.

Authors:  J J Lee; L Rouhfar; O R Beirne
Journal:  J Oral Maxillofac Surg       Date:  2000-12       Impact factor: 1.895

Review 4.  Interventions for replacing missing teeth: dental implants in fresh extraction sockets (immediate, immediate-delayed and delayed implants).

Authors:  Marco Esposito; Maria Gabriella Grusovin; Ilias P Polyzos; Pietro Felice; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2010-09-08

Review 5.  The effectiveness of immediate, early, and conventional loading of dental implants: a Cochrane systematic review of randomized controlled clinical trials.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Mark Willings; Paul Coulthard; Helen V Worthington
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Nov-Dec       Impact factor: 2.804

6.  Immediate loading of trabecular metal-enhanced titanium dental implants: interim results from an international proof-of-principle study.

Authors:  Marcus Schlee; W Peter van der Schoor; Alexandra R M van der Schoor
Journal:  Clin Implant Dent Relat Res       Date:  2013-07-30       Impact factor: 3.932

7.  Comparison of peri-implant crevicular fluid levels of adrenomedullin and human beta defensins 1 and 2 from mandibular implants with different implant stability quotient levels in nonsmoker patients.

Authors:  A S Ertugrul; Y Tekin; N Z Alpaslan; A Bozoglan; H Sahin; A Dikilitas
Journal:  J Periodontal Res       Date:  2013-07-31       Impact factor: 4.419

8.  Long-term survival of calcium phosphate-coated dental implants: a meta-analytical approach to the clinical literature.

Authors:  Bart A J A van Oirschot; Ewald M Bronkhorst; Jeroen J J P van den Beucken; Gert J Meijer; John A Jansen; Rüdiger Junker
Journal:  Clin Oral Implants Res       Date:  2012-11-05       Impact factor: 5.977

9.  Effect of loading time on marginal bone loss around hydroxyapatite-coated implants.

Authors:  Young-Kyun Kim; Kyo-Jin Ahn; Pil-Young Yun; Minkyoung Kim; Hong-So Yang; Yang-Jin Yi; Ji-Hyun Bae
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2013-08-23

10.  Clinical efficacy of early loading versus conventional loading of dental implants.

Authors:  Yanfei Zhu; Xinyi Zheng; Guanqi Zeng; Yi Xu; Xinhua Qu; Min Zhu; Eryi Lu
Journal:  Sci Rep       Date:  2015-11-06       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.