Literature DB >> 33750451

To explore the reasonable selection of clavicular hook plate to reduce the occurrence of subacromial impingement syndrome after operation.

Rui Qiao1,2, Jiarui Yang2, Kun Zhang1, Zhe Song3.   

Abstract

BACKGROUND: Acromioclavicular joint dislocation is a shoulder joint injury common in the clinical setting and is generally surgically treated with clavicular hook plate technique with confirmed curative effect. However, symptoms such as shoulder abduction limitation, shoulder discomfort and joint pain postoperatively may occur in some patients. Therefore, this study aimed to explore whether the existing clavicular hook plate can be reasonably selected to reduce the incidence of subacromial impingement syndrome (SIS) and provide a reference for clinical diagnosis and treatment.
MATERIALS AND METHODS: Patients with SIS admitted from March 2018 to June 2020 were selected as the experimental group and asymptomatic patients postoperatively, as the control group. The hook end depth and acromial height of the hook plate used in patients were recorded, and the difference between them was calculated.
RESULTS: The difference between the hook plate depth and acromial height was 7.500±1.912 mm and 6.563±1.537 mm in the experimental and control groups, respectively, with statistically significant difference (t=3.021, P=0.006). A difference of >0.6 mm as a grouping index is required to perform a single factor analysis, with statistically significant difference (t=3.908, P=0.048).
CONCLUSIONS: The occurrence of SIS after placing the clavicular hook plate may be related to the difference between its depth and the acromial height. A difference of >6 mm may be a factor affecting the occurrence of SIS. Pre-imaging measurement of the acromial height can provide suggestions for selecting the type of hook plate intraoperatively.

Entities:  

Keywords:  Acromioclavicular joint; Acromion impact sign; Clavicular hook plate; Dislocation

Year:  2021        PMID: 33750451      PMCID: PMC7944884          DOI: 10.1186/s13018-021-02325-5

Source DB:  PubMed          Journal:  J Orthop Surg Res        ISSN: 1749-799X            Impact factor:   2.359


  1 in total

1.  [Stabilisation of the dislocated acromioclavicular joint and lateral fractures of the clavicle using a hook plate].

Authors:  M Reška; J Konečný; M Kašpar; M Kábela; J Cierník
Journal:  Rozhl Chir       Date:  2013-03
  1 in total
  1 in total

Review 1.  Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures.

Authors:  Dashuang Li; Rui Qiao; Na Yang; Kun Zhang; Yangjun Zhu; Zhe Song
Journal:  J Orthop Surg Res       Date:  2022-10-12       Impact factor: 2.677

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.