Clinical analysis of CAD-CAM milled and printed complete dentures using computerized occlusal force analyser.

Saurabh Chaturvedi, Mohamed Khaled Addas, Nasser M Alqahtani, Nasser M Al Ahmari, Mohammed A Alfarsi.   

Abstract

BACKGROUND: Digital complete dentures (CDs) by computer-aided designing and computer-aided manufacturing (CAD-CAM) techniques (milling and three-dimensional (3-D) printing) have been evaluated clinically and provided satisfactory results. But clinical studies assessing occlusal forces by digital dentures are lacking.
OBJECTIVES: To compare the occlusal force parameters in complete dentures (CDs) fabricated by milling, 3-D printing and conventional techniques having 3 commonly used occlusal schemes, using computerized occlusal force analysis system (Tech-Scan III- T-Scan III).
METHODS: A total of 45 CDs were fabricated for 5 patients. Nine sets of CDs were made for each patient and were divided into 3 groups: Conventional CDs (CCD), Milled CDs (MCD), and 3-D printed CDs (3-DP CD). The CDs in each group were further divided into 3 sub-groups based on occlusion schemes - bilateral balanced (BBO), lingualized (LO) and mono plane (MP). Occlusal force analysis [percentage (%) of occlusal force applied on the right and left sides of the arch difference between them, centralization of forces and % of maximum occlusal/bite force] was done using computerized occlusal analysis system (T-Scan III) at the time of denture insertion. Univariate regression analysis and logistic regression analysis were performed (p< 0.05).
RESULTS: The intergroup comparison of force distribution on right and left side in CDs fabricated by various techniques showed insignificant differences (p> 0.05) but statistically significant differences (p< 0.01) were found in right-left side force difference, maximum bite force % and centralization of forces. The maximum force difference on right and left side was observed CCD with MO (37.48 ± 1.03 N) and maximum occlusal-bite force % was observed for 3-DPCD with LO (95.40 ± 1.30 N). In comparison to 3-DP CD, the chances of centre of force out of ellipse (centralization of forces) was 3.36 and 2.15 times more in CCD and MCD techniques made CDs respectively.
CONCLUSIONS: The occlusal parameters in CDs were affected by the fabrication techniques and occlusal schemes of CDs. The digital CDs retain adjusted occlusal schemes better and 3-DP CDs with BBO and LO occlusal schemes provided centralization of forces, better distribution and high maximum occlusal force % respectively.

Entities:  

Keywords:  CAD-CAM; Digital dentures; T-Scan; additive technique milling; occlusal forces; subtractive technique

Year:  2021        PMID: 33749624     DOI: 10.3233/THC-202766

Source DB:  PubMed          Journal:  Technol Health Care        ISSN: 0928-7329            Impact factor:   1.285


  1 in total

Review 1.  Assessment of Conventionally and Digitally Fabricated Complete Dentures: A Comprehensive Review.

Authors:  Manal Q Mubaraki; Mohammed M Al Moaleem; Abdulrahman H Alzahrani; Mansoor Shariff; Saeed M Alqahtani; Amit Porwal; Fuad A Al-Sanabani; Shilpa Bhandi; João Paulo Mendes Tribst; Artak Heboyan; Shankargouda Patil
Journal:  Materials (Basel)       Date:  2022-05-28       Impact factor: 3.748

  1 in total