Literature DB >> 33748769

Sub-Nanowatt Ultrasonic Bio-Telemetry Using B-Scan Imaging.

Sri Harsha Kondapalli1, Shantanu Chakrabartty1.   

Abstract

GOAL: The objective of this paper is to investigate if the use of a B-scan ultrasound imaging system can reduce the energy requirements, and hence the power-dissipation requirements to support wireless bio-telemetry at an implantable device.
METHODS: B-scan imaging data were acquired using a commercial 256-element linear ultrasound transducer array which was driven by a commercial echoscope. As a transmission medium, we used a water-bath and the operation of the implantable device was emulated using a commercial-off-the-shelf micro-controller board. The telemetry parameters (e.g. transmission rate and transmission power) were wirelessly controlled using a two-way radio-frequency transceiver. B-scan imaging data were post-processed using a maximum-threshold decoder and the quality of the ultrasonic telemetry link was quantified in terms of its bit-error-rate (BER).
RESULTS: Measured results show that a reliable B-scan communication link with an implantable device can be achieved at transmission power levels of 100 pW and for implantation depths greater than 10 cm.
CONCLUSIONS: In this paper we demonstrated that a combination of B-scan imaging and a simple decoding algorithm can significantly reduce the energy-budget requirements for reliable ultrasonic telemetry.

Entities:  

Keywords:  B-Scan imaging; echoscope; low-power communication; ultrasound telemetry

Year:  2021        PMID: 33748769      PMCID: PMC7978362          DOI: 10.1109/ojemb.2021.3053174

Source DB:  PubMed          Journal:  IEEE Open J Eng Med Biol        ISSN: 2644-1276


  9 in total

1.  Spinal-fusion surgery - the case for restraint.

Authors:  Richard A Deyo; Alf Nachemson; Sohail K Mirza
Journal:  N Engl J Med       Date:  2004-02-12       Impact factor: 91.245

Review 2.  Principles of bone healing.

Authors:  I H Kalfas
Journal:  Neurosurg Focus       Date:  2001-04-15       Impact factor: 4.047

Review 3.  Ultrasonic monitoring of bone fracture healing.

Authors:  Vasilios C Protopappas; Maria G Vavva; Dimitrios I Fotiadis; Konstantinos N Malizos
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

4.  Multiaccess In Vivo Biotelemetry Using Sonomicrometry and M-Scan Ultrasound Imaging.

Authors:  Sri Harsha Kondapalli; Yarub Alazzawi; Marcin Malinowski; Tomasz Timek; Shantanu Chakrabartty
Journal:  IEEE Trans Biomed Eng       Date:  2017-04-25       Impact factor: 4.538

5.  Enabling Ultrasound In-Body Communication: FIR Channel Models and QAM Experiments.

Authors:  Thomas Bos; Wentao Jiang; Jan D'hooge; Marian Verhelst; Wim Dehaene
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2018-11-12       Impact factor: 3.833

6.  Feasibility of Self-Powering and Energy Harvesting Using Cardiac Valvular Perturbations.

Authors:  Sri Harsha Kondapalli; Yarub Alazzawi; Marcin Malinowski; Tomasz Timek; Shantanu Chakrabartty
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2018-08-14       Impact factor: 3.833

7.  Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust.

Authors:  Dongjin Seo; Ryan M Neely; Konlin Shen; Utkarsh Singhal; Elad Alon; Jan M Rabaey; Jose M Carmena; Michel M Maharbiz
Journal:  Neuron       Date:  2016-08-03       Impact factor: 17.173

8.  Monitoring of Postoperative Bone Healing Using Smart Trauma-Fixation Device With Integrated Self-Powered Piezo-Floating-Gate Sensors.

Authors:  Wassim Borchani; Kenji Aono; Nizar Lajnef; Shantanu Chakrabartty
Journal:  IEEE Trans Biomed Eng       Date:  2015-10-30       Impact factor: 4.538

9.  Ultrasound Intra Body Multi Node Communication System for Bioelectronic Medicine.

Authors:  Banafsaj Jaafar; JunWen Luo; Dimitrios Firfilionis; Ahmed Soltan; Jeff Neasham; Patrick Degenaar
Journal:  Sensors (Basel)       Date:  2019-12-19       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.