Literature DB >> 33747415

Computed Tomography- (CT-) Based Virtual Surgery Planning for Spinal Intervertebral Foraminal Assisted Clinical Treatment.

Hao Li1, Song Wang1, Jinlong Tang1, Jibin Wu1, Yong Liu1.   

Abstract

With the development of minimally invasive spine concepts and the introduction of new minimally invasive instruments, minimally invasive spine technology, represented by foraminoscopy, has flourished, and percutaneous foraminoscopy has become one of the most reliable minimally invasive procedures for the treatment of lumbar disc herniation. Percutaneous foraminoscopy is a safe and effective minimally invasive spinal endoscopic surgical technique. It fully protects the paravertebral muscles and soft tissues as well as the posterior column structure of the spine, provides precise treatment of the target nucleus pulposus tissue, with the advantages of less surgical trauma, fewer postoperative complications, and rapid postoperative recovery, and is widely promoted and used in clinical practice. In this paper, we can view the location, morphology, structure, alignment, and adjacency relationships by performing coronary, CT, and diagonal reconstruction along the attachment of the yellow ligaments and performing 3D reconstruction or processing techniques after performing CT scans. This allows clinicians to observe the laminoplasty and the stenosis of the vertebral canal in a more intuitive and overall manner. It has clinical significance for the display of the sublaminar spine as well as the physician's judgment of the disease and the choice of surgery.
Copyright © 2021 Hao Li et al.

Entities:  

Year:  2021        PMID: 33747415      PMCID: PMC7960066          DOI: 10.1155/2021/5521916

Source DB:  PubMed          Journal:  J Healthc Eng        ISSN: 2040-2295            Impact factor:   2.682


  20 in total

1.  Detection of Lumbar Disk Herniation with Virtual Noncalcium Dual-Energy CT: Is This a Real Virtual Noncalcium Image?

Authors:  Chankue Park; JaeWon Choi; Hee Seok Jeong
Journal:  Radiology       Date:  2019-07-02       Impact factor: 11.105

2.  Improvement of Image Quality in Unenhanced Dual-Layer CT of the Head Using Virtual Monoenergetic Images Compared With Polyenergetic Single-Energy CT.

Authors:  Victor Neuhaus; Nuran Abdullayev; Nils Große Hokamp; Gregor Pahn; Christoph Kabbasch; Anastasios Mpotsaris; David Maintz; Jan Borggrefe
Journal:  Invest Radiol       Date:  2017-08       Impact factor: 6.016

3.  Zero TE-based pseudo-CT image conversion in the head and its application in PET/MR attenuation correction and MR-guided radiation therapy planning.

Authors:  Florian Wiesinger; Mikael Bylund; Jaewon Yang; Sandeep Kaushik; Dattesh Shanbhag; Sangtae Ahn; Joakim H Jonsson; Josef A Lundman; Thomas Hope; Tufve Nyholm; Peder Larson; Cristina Cozzini
Journal:  Magn Reson Med       Date:  2018-02-18       Impact factor: 4.668

4.  Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms.

Authors:  Nils Große Hokamp; V Neuhaus; N Abdullayev; K Laukamp; S Lennartz; A Mpotsaris; J Borggrefe
Journal:  Skeletal Radiol       Date:  2017-09-21       Impact factor: 2.199

5.  Techniques for virtual lung nodule insertion: volumetric and morphometric comparison of projection-based and image-based methods for quantitative CT.

Authors:  Marthony Robins; Justin Solomon; Pooyan Sahbaee; Martin Sedlmair; Kingshuk Roy Choudhury; Aria Pezeshk; Berkman Sahiner; Ehsan Samei
Journal:  Phys Med Biol       Date:  2017-08-22       Impact factor: 3.609

6.  Stereotactic CT image guidance and biplanar fluoroscopy for transoral C2 vertebroplasty and direct anterolateral subaxial vertebroplasty: a surgical technique note on access to the axial and subaxial spine.

Authors:  Miki Katzir; Nguyen Hoang; Eric Bourekas; Ricardo Carrau; Ehud Mendel
Journal:  Acta Neurochir (Wien)       Date:  2020-06-23       Impact factor: 2.216

7.  Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion.

Authors:  A Sisniega; J W Stayman; J Yorkston; J H Siewerdsen; W Zbijewski
Journal:  Phys Med Biol       Date:  2017-03-22       Impact factor: 3.609

Review 8.  Applications of nonlocal means algorithm in low-dose X-ray CT image processing and reconstruction: A review.

Authors:  Hao Zhang; Dong Zeng; Hua Zhang; Jing Wang; Zhengrong Liang; Jianhua Ma
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.071

9.  Optimal virtual monoenergetic image in "TwinBeam" dual-energy CT for organs-at-risk delineation based on contrast-noise-ratio in head-and-neck radiotherapy.

Authors:  Tonghe Wang; Beth Bradshaw Ghavidel; Jonathan J Beitler; Xiangyang Tang; Yang Lei; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  J Appl Clin Med Phys       Date:  2019-01-28       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.