Literature DB >> 33746488

Simulation-based study of COVID-19 outbreak associated with air-conditioning in a restaurant.

Han Liu1, Sida He1, Lian Shen1, Jiarong Hong1.   

Abstract

COVID-19 has shown a high potential of transmission via virus-carrying aerosols as supported by growing evidence. However, detailed investigations that draw direct links between aerosol transport and virus infection are still lacking. To fill in the gap, we conducted a systematic computational fluid dynamics (CFD)-based investigation of indoor airflow and the associated aerosol transport in a restaurant setting, where likely cases of airflow-induced infection of COVID-19 caused by asymptomatic individuals were widely reported by the media. We employed an advanced in-house large eddy simulation solver and other cutting-edge numerical methods to resolve complex indoor processes simultaneously, including turbulence, flow-aerosol interplay, thermal effect, and the filtration effect by air conditioners. Using the aerosol exposure index derived from the simulation, we are able to provide a spatial map of the airborne infection risk under different settings. Our results have shown a remarkable direct linkage between regions of high aerosol exposure index and the reported infection patterns in the restaurant, providing strong support to the airborne transmission occurring in this widely reported incident. Using flow structure analysis and reverse-time tracing of aerosol trajectories, we are able to further pinpoint the influence of environmental parameters on the infection risks and highlight the need for more effective preventive measures, e.g., placement of shielding according to the local flow patterns. Our research, thus, has demonstrated the capability and value of high-fidelity CFD tools for airborne infection risk assessment and the development of effective preventive measures.
© 2021 Author(s).

Entities:  

Year:  2021        PMID: 33746488      PMCID: PMC7976041          DOI: 10.1063/5.0040188

Source DB:  PubMed          Journal:  Phys Fluids (1994)        ISSN: 1070-6631            Impact factor:   3.521


  18 in total

1.  Environmental Surveillance for SARS-CoV-2 in Two Restaurants from a Mid-scale City that Followed U.S. CDC Reopening Guidance.

Authors:  Hongwan Li; Sripriya Nannu Shankar; Chiran T Witanachchi; John A Lednicky; Julia C Loeb; Md Mahbubul Alam; Z Hugh Fan; Karim Mohamed; Jessica A Boyette; Arantzazu Eiguren-Fernandez; Chang-Yu Wu
Journal:  Aerosol Air Qual Res       Date:  2021-12-03       Impact factor: 3.063

2.  Modeling of aerosol transmission of airborne pathogens in ICU rooms of COVID-19 patients with acute respiratory failure.

Authors:  Cyril Crawford; Emmanuel Vanoli; Baptiste Decorde; Maxime Lancelot; Camille Duprat; Christophe Josserand; Jonathan Jilesen; Lila Bouadma; Jean-François Timsit
Journal:  Sci Rep       Date:  2021-06-03       Impact factor: 4.379

3.  Numerical investigation of droplets in a cross-ventilated space with sitting passengers under asymptomatic virus transmission conditions.

Authors:  C Peña-Monferrer; S Antao; R Manson-Sawko
Journal:  Phys Fluids (1994)       Date:  2021-12-21       Impact factor: 3.521

4.  Exposure risk analysis of COVID-19 for a ride-sharing motorbike taxi.

Authors:  R Hetherington; A B M Toufique Hasan; A Khan; D Roy; M Salehin; Z Wadud
Journal:  Phys Fluids (1994)       Date:  2021-11-17       Impact factor: 3.521

5.  Risk assessment of COVID infection by respiratory droplets from cough for various ventilation scenarios inside an elevator: An OpenFOAM-based computational fluid dynamics analysis.

Authors:  Riddhideep Biswas; Anish Pal; Ritam Pal; Sourav Sarkar; Achintya Mukhopadhyay
Journal:  Phys Fluids (1994)       Date:  2022-01-24       Impact factor: 3.521

6.  High-resolution large-eddy simulation of indoor turbulence and its effect on airborne transmission of respiratory pathogens-Model validation and infection probability analysis.

Authors:  Mikko Auvinen; Joel Kuula; Tiia Grönholm; Matthias Sühring; Antti Hellsten
Journal:  Phys Fluids (1994)       Date:  2022-01-19       Impact factor: 3.521

7.  Airborne transmission of COVID-19 and mitigation using box fan air cleaners in a poorly ventilated classroom.

Authors:  Ruichen He; Wanjiao Liu; John Elson; Rainer Vogt; Clay Maranville; Jiarong Hong
Journal:  Phys Fluids (1994)       Date:  2021-05-11       Impact factor: 3.521

8.  Droplet fate, efficacy of face mask, and transmission of virus-laden droplets inside a conference room.

Authors:  Dnyanesh Mirikar; Silambarasan Palanivel; Venugopal Arumuru
Journal:  Phys Fluids (1994)       Date:  2021-06-03       Impact factor: 4.980

9.  Double masking protection vs. comfort-A quantitative assessment.

Authors:  Venugopal Arumuru; Sidhartha Sankar Samantaray; Jangyadatta Pasa
Journal:  Phys Fluids (1994)       Date:  2021-07-21       Impact factor: 3.521

Review 10.  The existence, spread, and strategies for environmental monitoring and control of SARS-CoV-2 in environmental media.

Authors:  Zhongchuang Liu; Krzysztof Skowron; Katarzyna Grudlewska-Buda; Natalia Wiktorczyk-Kapischke
Journal:  Sci Total Environ       Date:  2021-07-07       Impact factor: 7.963

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.