Continuous non-contact respiratory rate and tidal volume monitoring using a Depth Sensing Camera.

Paul S Addison1, Philip Smit2, Dominique Jacquel2, Anthony P Addison2, Cyndy Miller3, Gardner Kimm3.   

Abstract

The monitoring of respiratory parameters is important across many areas of care within the hospital. Here we report on the performance of a depth-sensing camera system for the continuous non-contact monitoring of Respiratory Rate (RR) and Tidal Volume (TV), where these parameters were compared to a ventilator reference. Depth sensing data streams were acquired and processed over a series of runs on a single volunteer comprising a range of respiratory rates and tidal volumes to generate depth-based respiratory rate (RRdepth) and tidal volume (TVdepth) estimates. The bias and root mean squared difference (RMSD) accuracy between RRdepth and the ventilator reference, RRvent, across the whole data set was found to be -0.02 breaths/min and 0.51 breaths/min respectively. The least squares fit regression equation was determined to be: RRdepth = 0.96 × RRvent + 0.57 breaths/min and the resulting Pearson correlation coefficient, R, was 0.98 (p < 0.001). Correspondingly, the bias and root mean squared difference (RMSD) accuracy between TVdepth and the reference TVvent across the whole data set was found to be - 0.21 L and 0.23 L respectively. The least squares fit regression equation was determined to be: TVdepth = 0.79 × TVvent-0.01 L and the resulting Pearson correlation coefficient, R, was 0.92 (p < 0.001). In conclusion, a high degree of agreement was found between the depth-based respiration rate and its ventilator reference, indicating that RRdepth is a promising modality for the accurate non-contact respiratory rate monitoring in the clinical setting. In addition, a high degree of correlation between depth-based tidal volume and its ventilator reference was found, indicating that TVdepth may provide a useful monitor of tidal volume trending in practice. Future work should aim to further test these parameters in the clinical setting.
© 2021. The Author(s).

Entities:  

Keywords:  COVID-19; Depth sensing camera; Respiratory function; Respiratory rate; Tidal volume

Mesh:

Year:  2021        PMID: 33743106      PMCID: PMC7980749          DOI: 10.1007/s10877-021-00691-3

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   1.977


  3 in total

Review 1.  Incidence, Reversal, and Prevention of Opioid-induced Respiratory Depression.

Authors:  Albert Dahan; Leon Aarts; Terry W Smith
Journal:  Anesthesiology       Date:  2010-01       Impact factor: 7.892

Review 2.  Telemedicine for preoperative assessment during a COVID-19 pandemic: Recommendations for clinical care.

Authors:  Maks Mihalj; Thierry Carrel; Igor D Gregoric; Lukas Andereggen; Pascal O Zinn; Dietrich Doll; Frank Stueber; Rodney A Gabriel; Richard D Urman; Markus M Luedi
Journal:  Best Pract Res Clin Anaesthesiol       Date:  2020-05-14

3.  Continuous respiratory rate monitoring during an acute hypoxic challenge using a depth sensing camera.

Authors:  Paul S Addison; Philip Smit; Dominique Jacquel; Ulf R Borg
Journal:  J Clin Monit Comput       Date:  2019-11-08       Impact factor: 2.502

  3 in total
  1 in total

1.  Cardio-respiratory and phenotypic rescue of dystrophin/utrophin-deficient mice by combination therapy.

Authors:  Caorui Lin; Gang Han; Lulu Jia; Yiwen Zhao; Jun Song; Ning Ran; Toshifumi Yokota; Yiqi Seow; HaiFang Yin
Journal:  EMBO Rep       Date:  2022-04-08       Impact factor: 9.071

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.