Literature DB >> 33741142

A comparison of ceramic crown color difference between different shade selection methods: Visual, digital camera, and smartphone.

Gilbert J Jorquera1, Pablo J Atria2, Mariana Galán3, Josefina Feureisen3, Makarena Imbarak3, Jeremy Kernitsky3, Franco Cacciuttolo1, Ronaldo Hirata4, Camila S Sampaio5.   

Abstract

STATEMENT OF PROBLEM: The light source stability of digital cameras and smartphones is important in shade matching in restorative and prosthetic dentistry to communicate objectively with the dental laboratory. Techniques that standardize the light source of such devices are lacking, and this limitation can lead to color mismatches, difficulties in color communication, and treatment documentation.
PURPOSE: The purpose of this clinical study was to compare the magnitude of color difference (ΔE) among 3 shade selection methods during the fabrication of ceramic crowns: visual shade selection with a shade guide, digital shade selection with a digital camera and cross-polarizing filter, and digital shade selection with a smartphone and a light-correcting device.
MATERIAL AND METHODS: Forty-five patients in need of ceramic crowns were enrolled, and shade selection was evaluated according to different protocols: visual shade selection (A-D shade guide and IPS Natural Die Material Shade Guide, sent to the dental laboratory technician via a laboratory prescription); digital shade selection with a digital camera (D7000; Nikon Corp) with an 85-mm lens and wireless close-up flash, with and without a cross-polarizing filter (Polar eyes); and digital shade selection with a smartphone and a light-correcting device (iPhone XS attached to Smile Lite MDP, with and without its cross-polarizing filter accessory). Information from the smartphone was imported to an app (IPS e.max Shade Navigation App; Ivoclar Vivadent AG) that converted the reading to a shade and level of translucency for the ceramic restoration. For all photographs, a gray reference card with known color values was positioned by the mandibular teeth and was used for white balancing of the digital photographs with a software program. All photographs were edited and sent to the dental laboratory: white-balanced with the shade guide; white-balanced with the substrate shade guide; black and white; saturated; and cross-polarized. Ceramic crowns were made with the same lithium disilicate material (IPS e.max CAD; Ivoclar Vivadent AG) and cemented with the same resin cement (RelyX Ultimate Clicker, A3 shade; 3M). The ΔE values between the crown and the adjacent tooth were determined. The data were analyzed by using a 1-way analysis of variance (ANOVA) and Tukey posthoc tests (α=.05).
RESULTS: The mean ΔE between a cemented ceramic crown and the adjacent tooth in the visual shade selection group was 5.32, significantly different than both digital camera (ΔE=2.75; P=.002) and smartphone (ΔE=2.34; P=.001), which were not different from each other (P=.857).
CONCLUSIONS: The digital shade selection with photographs acquired with both a digital camera and a smartphone with a light-correcting device showed a threshold within the acceptable values (ΔE<3.7), whereas the visual shade selection showed an average ΔE above the threshold for acceptable values (ΔE>3.7). The use of a gray reference card helped standardize the white balance from the digital images.
Copyright © 2020 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2021        PMID: 33741142     DOI: 10.1016/j.prosdent.2020.07.029

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  Translucency of a Dental Porcelain Mixed by Two Ceramic Slurry Methods: A Bayesian Comparison.

Authors:  Catalina Serna-Meneses; Gabriel Ocampo-Parra; Santiago Arango-Santander; Claudia Garcia-Garcia; Luis Felipe Restrepo-Tamayo; Johnatan Cardona-Jimenez; Alexander Ossa; Alejandro Pelaez-Vargas
Journal:  Int J Dent       Date:  2022-06-06

Review 2.  Novel Trends in Dental Color Match Using Different Shade Selection Methods: A Systematic Review and Meta-Analysis.

Authors:  Louis Hardan; Rim Bourgi; Carlos Enrique Cuevas-Suárez; Monika Lukomska-Szymanska; Ana Josefina Monjarás-Ávila; Maciej Zarow; Natalia Jakubowicz; Gilbert Jorquera; Tarek Ashi; Davide Mancino; Naji Kharouf; Youssef Haikel
Journal:  Materials (Basel)       Date:  2022-01-08       Impact factor: 3.623

3.  Accuracy of Dental Photography: Professional vs. Smartphone's Camera.

Authors:  Carol Moussa; Louis Hardan; Cynthia Kassis; Rim Bourgi; Walter Devoto; Gilbert Jorquera; Saurav Panda; Roy Abou Fadel; Carlos Enrique Cuevas-Suárez; Monika Lukomska-Szymanska
Journal:  Biomed Res Int       Date:  2021-12-15       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.