Semi-automatic measurements of foot morphological parameters from 3D plantar foot scans.

Giulia Rogati1, Alberto Leardini2, Maurizio Ortolani2, Paolo Caravaggi2.   

Abstract

BACKGROUND: Foot healthcare research is focusing increasingly on personalized orthotic and prosthetic devices to address patient-specific morphology and ailments. Customization requires advanced 3D image processing tools to assess foot and leg geometrical parameters and alterations. The aim of this study is to present a new software for the measurement of the foot shape from 3D scans of the foot plantar surface.
METHODS: A Kinect-based scanning device was used to acquire the 3D foot shape of 44 healthy subjects. A software was developed in Matlab to measure the foot main morphological parameters from foot scans. Principal Component Analysis was used to orientate the foot scans with respect to the same reference system. Accuracy, via percentage errors and Bland-Altman plots, and correlation of the software-based foot parameters were assessed against manual measurements. A normalized Arch Volume Index (nAVI) was proposed and correlated to the traditional Arch Index. Test-retest Intraclass Correlation Coefficient was used to assess the inter-session repeatability of foot measurements.
RESULTS: The average percentage error between software and manual measurements was 1.2 ± 0.8% for foot length, 9.1 ± 3.7% for foot width, 22.3 ± 13.5% for arch height and 23.1 ± 12.7% for arch depth. Very strong correlations were observed for foot length (R = 0.97) and foot width (R = 0.83), and strong correlations for arch height (R = 0.62) and arch depth (R = 0.74). nAVI was negatively correlated to the Arch Index (R = -0.54). A small difference was found between software and manual measurements of foot length (Δ = 0.92 mm), a software overestimation of foot width (Δ = 8.6 mm) and underestimation of arch height (Δ = -1.4%) and arch depth (Δ = -11%). Moderate to excellent repeatability was observed for all measurements (0.67-0.99).
CONCLUSIONS: The present software appears capable to estimate the foot main morphological parameters without the need for skin markers or for identification of anatomical landmarks. Moreover, measurements are not affected by the foot orientation on the scanning device. The good accuracy and repeatability of measurements make the software a potentially useful operator-independent tool for the assessment of foot morphological alterations and for orthotics customization. nAVI may be used for a more realistic classification of foot types when 3D foot images are available.

Entities:  

Keywords:  3D scans; Custom software; Foot; Foot morphological parameters; Medial longitudinal arch

Year:  2021        PMID: 33731179      PMCID: PMC7972185          DOI: 10.1186/s13047-021-00461-z

Source DB:  PubMed          Journal:  J Foot Ankle Res        ISSN: 1757-1146            Impact factor:   2.303


  25 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Measurements used to characterize the foot and the medial longitudinal arch: reliability and validity.

Authors:  D S Williams; I S McClay
Journal:  Phys Ther       Date:  2000-09

3.  Variability of neutral-position casting of the foot.

Authors:  Vivienne Chuter; Craig Payne; Kathryn Miller
Journal:  J Am Podiatr Med Assoc       Date:  2003 Jan-Feb

4.  Foot and ankle strength, range of motion, posture, and deformity are associated with balance and functional ability in older adults.

Authors:  Martin J Spink; Mohammad R Fotoohabadi; Elin Wee; Keith D Hill; Stephen R Lord; Hylton B Menz
Journal:  Arch Phys Med Rehabil       Date:  2011-01       Impact factor: 3.966

5.  Effect of feet hyperpronation on pelvic alignment in a standing position.

Authors:  Sam Khamis; Ziva Yizhar
Journal:  Gait Posture       Date:  2006-04-18       Impact factor: 2.840

6.  Influence of a custom foot orthotic intervention on lower extremity dynamics in healthy runners.

Authors:  Christopher MacLean; Irene McClay Davis; Joseph Hamill
Journal:  Clin Biomech (Bristol, Avon)       Date:  2006-04-05       Impact factor: 2.063

7.  The reliability and reproducibility of foot type measurements using a mirrored foot photo box and digital photography compared to caliper measurements.

Authors:  Nathan A Mall; W Mack Hardaker; James A Nunley; Robin M Queen
Journal:  J Biomech       Date:  2006-07-05       Impact factor: 2.712

8.  Foot posture, foot function and low back pain: the Framingham Foot Study.

Authors:  Hylton B Menz; Alyssa B Dufour; Jody L Riskowski; Howard J Hillstrom; Marian T Hannan
Journal:  Rheumatology (Oxford)       Date:  2013-09-17       Impact factor: 7.580

9.  Hyperpronation and foot pain: steps toward pain-free feet.

Authors:  Steven D Stovitz; J Chris Coetzee
Journal:  Phys Sportsmed       Date:  2004-08       Impact factor: 2.241

10.  The use of 3D surface scanning for the measurement and assessment of the human foot.

Authors:  Scott Telfer; James Woodburn
Journal:  J Foot Ankle Res       Date:  2010-09-05       Impact factor: 2.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.