Andrés Fernando Montenegro Arana1, Barbara Justus2, Andrés DÁvila-SÁnchez3, Michele de Oliveira Sugahara4, Ulisses Coelho1, Paulo Vitor Farago2, Cesar Arrais1.
Abstract
INTRODUCTION: Third generation of LED light curing units might be used in short exposure periods for orthodontic brackets bonding.Entities:
Mesh:
Substances:
Year: 2021 PMID: 33729290 PMCID: PMC8018747 DOI: 10.1590/2177-6709.26.1.e2119150.oar
Source DB: PubMed Journal: Dental Press J Orthod ISSN: 2176-9451
Experimental groups evaluated in the study.
| LED LCU | Bracket | Exposure mode | Radiant emittance (mW/cm2) | Exposure period (s) | Radiant Exposure values (J/cm2) | Group name | Description |
|---|---|---|---|---|---|---|---|
| Valo | Metallic | Standard power | 1273 | 18 | 22.9 | MI | Control |
| 9 | 11.5 | ½ MI | Half control time | ||||
| 5 | 6.4 | ¼ MI | Quarter control time | ||||
| Plasma Emulation | 3200 | 6.6 | 21.1 | Turbo | Plasma | ||
| Ceramic | Standard power | 1273 | 9 | 11.5 | MI | Control | |
| 4.5 | 5.7 | ½ MI | Half control time | ||||
| 2.25 | 2.9 | ¼ MI | Quarter control time | ||||
| Plasma Emulation | 3200 | 3.33 | 10.7 | Turbo | Plasma | ||
| Bluephase | Metallic | Standard power | 1136 | 20 | 22.7 | MI | Control |
| 10 | 11.36 | ½ MI | Half control time | ||||
| 5 | 5.68 | ¼ MI | Quarter control time | ||||
| Turbo | 2045 | 6 | 12.3 | Turbo | Turbo | ||
| Ceramic | Standard power | 1136 | 10 | 11.36 | MI | Control | |
| 5 | 5.68 | ½ MI | Half control time | ||||
| 2.5 | 2.84 | ¼ MI | Quarter control time | ||||
| Turbo | 2045 | 3 | 6.12 | Turbo | Turbo |
Figure 1:Illustrative image of OC layer on metallic ( A ) and ceramic ( B ) brackets and all indentations made in each corner.
Mean (SD) DC values after exposure to light emitted from LCUs at varying radiant exposure values under metallic and ceramic brackets.
| Irradiation | Metallic | Ceramic | |
|---|---|---|---|
| VALO | MI | 35.8 (3.4)Ab | 47.0 (1.6)Aa |
| ½ MI | 27.0 (4.4)BCb | 44.7 (1.4)Aa | |
| ¼ MI | 21.6 (6.9)Cb | 43.0 (1.9)Aa | |
| Turbo MI | 31.6 (5.4) ABb | 44.4 (1.5)Aa | |
| Bluephase20i | MI | 35.0 (3.5) Ab | 45.6 (1.4)Aa |
| ½ MI | 28.0 (3.1)Bb | 43.6 (1.2)Aa | |
| ¼ MI | 23.7 (6.1)Bb | 44.0 (2.3)Aa | |
| Turbo MI | 28.2 (5.8)Bb | 46.2 (2.0)Aa |
* Significant differences between means are followed by different superscript letters (uppercase within column; lower case within row, pre-set alpha of 0.05). No comparison between results of different LCUs was performed.
Mean (SD) Rpmax values after exposure to light emitted from VALO and Bluephase 20i at varying radiant exposure values under metallic and ceramic brackets.
| Irradiation | Metallic | Ceramic | |
|---|---|---|---|
| VALO | MI | 2.7 (1.1)Ab | 10.9 (1.5)Ba |
| ½ MI | 2.4 (0.8)Ab | 10.6 (1.0)Ba | |
| ¼ MI | 2.8 (1.0)Ab | 11.0 (1.3)Ba | |
| Turbo MI | 3.9 (1.8)Ab | 14.0 (1.5)Aa | |
| Bluephase20i | MI | 2.6 (1.1)Ab | 10.5 (1.6)Ba |
| ½ MI | 2.4 (0.8)Ab | 10.3 (1.2)Ba | |
| ¼ MI | 3.1 (1.2)Ab | 11.2 (1.3)Ba | |
| Turbo MI | 2.9 (0.8)Ab | 14.0 (1.5)Aa |
* Significant differences between means are followed by different superscript letters (uppercase within column; lower case within row, pre-set alpha of 0.05). No comparison between results of different LCUs was performed
Figure 2:Representative real-time kinetic profile of monomer conversion of OC layer at varying exposure conditions under either metallic ( M ) or ceramic ( C ) brackets, during exposure to light emitted from VALO or Bluephase20i.
Mean (SD) VHN values after exposure to light emitted from the LCUs at varying radiant exposure values under metallic and ceramic brackets.
| Irradiation | Metallic | Ceramic | |
|---|---|---|---|
| VALO | MI | 42.4 (1.4)Aa | 41.8 (2.1)Aa |
| ½ MI | 32.7 (1.6)Bb | 37.3 (2.2)Ba | |
| ¼ MI | 21.1 (1.0)Cb | 30.0 (1.0)Ca | |
| Turbo MI | 31.3 (1.8)Bb | 35.7 (0.6)Ba | |
| Bluephase20i | MI | 40.1 (1.4)Aa | 41.4 (1.1)Aa |
| ½ MI | 29.7 (1.4)Cb | 39.0 (1.3)Ba | |
| ¼ MI | 19.3 (1.5)Db | 30.4 (1.4)Da | |
| Turbo MI | 32.1 (1.3)Bb | 36.1 (1.5)Ca |
* Significant differences between means are followed by different superscript letters (uppercase within column; lower case within row, pre-set alpha of 0.05). No comparison between results of different LCUs was performed.
Figure 3:Regression analysis plot of DC and VHN values vs delivered RE by VALO through metallic (A and C, respectively) or ceramic brackets (B and D, respectively).
Figure 4:Regression analysis plot of DC and VHN values vs delivered RE by Bluephase20i through metallic (A and C, respectively) or ceramic brackets (B and D, respectively).