Literature DB >> 33724442

Electrical conductance for the detection of dental caries.

Richard Macey1, Tanya Walsh1, Philip Riley2, Anne-Marie Glenny1, Helen V Worthington2, Janet E Clarkson3, David Ricketts4.   

Abstract

BACKGROUND: Caries is one of the most prevalent, preventable conditions worldwide. A wide variety of management options are available at different thresholds of disease, ranging from non-operative preventive strategies such as improved oral hygiene, reduced sugar diet, and application of topical fluoride, to minimally invasive treatments for early lesions which are limited to enamel, through to selective removal and restoration for extensive lesions. The cornerstone of caries detection is a visual and tactile dental examination, however, an increasing array of methods of caries lesion detection have been proposed that could potentially support traditional methods of detection and diagnosis. Earlier identification of disease could afford patients the opportunity of less invasive treatment with less destruction of tooth tissue, reduce the need for treatment with aerosol-generating procedures, and potentially result in a reduced cost of care to the patient and to healthcare services.
OBJECTIVES: Our primary objective was to determine the diagnostic accuracy of different electrical conductance devices for the detection and diagnosis of non-cavitated coronal dental caries in different populations (children, adolescents, and adults) and when tested against different reference standards. SEARCH
METHODS: Cochrane Oral Health's Information Specialist undertook a search of the following databases: MEDLINE Ovid (1946 to 26 April 2019); Embase Ovid (1980 to 26 April 2019); US National Institutes of Health Ongoing Trials Register (ClinicalTrials.gov, to 26 April 2019); and the World Health Organization International Clinical Trials Registry Platform (to 26 April 2019). We studied reference lists as well as published systematic review articles. SELECTION CRITERIA: We included diagnostic accuracy studies that compared electrical conductance devices with a reference standard of histology or an enhanced visual examination. This included prospective studies that evaluated the diagnostic accuracy of single index tests and studies that directly compared two or more index tests. We included studies using previously extracted teeth or those that recruited participants with teeth believed to be sound or with early lesions limited to enamel. Studies that explicitly recruited participants with more advanced lesions that were obviously into dentine or frankly cavitated were excluded. DATA COLLECTION AND ANALYSIS: Two review authors extracted data independently using a piloted study data extraction form based on the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Sensitivity and specificity with 95% confidence intervals (CIs) were reported for each study. This information was displayed as coupled forest plots, and plotted as summary receiver operating characteristic (SROC) plots, displaying the sensitivity-specificity points for each study. Due to variability in thresholds we estimated diagnostic accuracy using hierarchical summary receiver operating characteristic (HSROC) methods. MAIN
RESULTS: We included seven studies reporting a total of 719 tooth sites or surfaces, with an overall prevalence of the target condition of 73% (528 tooth sites or surfaces). The included studies evaluated two index tests: the electronic caries monitor (ECM) (four studies, 475 tooth surfaces) and CarieScan Pro (three studies, 244 tooth surfaces). Six studies used histology as the reference standard, one used an enhanced visual examination. No study was considered to be at low risk of bias across all four domains or low concern for applicability or both. All studies were at high (five studies) or unclear (two studies) risk of bias for the patient selection domain. We judged two studies to be at unclear risk of bias for the index test domain, and one study to be at high risk of bias for the reference standard and flow and timing domains. We judged three studies to be at low concern for applicability for patient selection, and all seven studies to be of low concern for reference standard and flow and timing domains. Studies were synthesised using a hierarchical method for meta-analysis. There was variability in the results of the individual studies, with sensitivities which ranged from 0.55 to 0.98 and specificities from 0 to 1.00. These extreme values of specificity may be explained by a low number of healthy tooth surfaces in the included samples. The diagnostic odds ratio (DOR) was 15.65 (95% CI 1.43 to 171.15), and indicative of the variability in the included studies. Through meta-regression we observed no meaningful difference in accuracy according to device type or dentition. Due to the small number of studies we were unable to formally investigate other potential sources of heterogeneity. We judged the certainty of the evidence as very low, and downgraded for risk of bias due to limitations in the design and conduct of the included studies, imprecision arising from the relatively small number of surfaces studied, and inconsistency due to the variability of results. AUTHORS'
CONCLUSIONS: The design and conduct of studies to determine the diagnostic accuracy of methods to detect and diagnose caries in situ is particularly challenging. The evidence base to support the detection and diagnosis of caries with electrical conductance devices is sparse. Newer electrical conductance devices show promise and further research at the enamel caries threshold using a robust study design to minimise bias is warranted. In terms of applicability, any future studies should be carried out in a clinical setting to provide a realistic assessment within the oral cavity where plaque, staining, and restorations can be problematic.
Copyright © 2021 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2021        PMID: 33724442      PMCID: PMC8406820          DOI: 10.1002/14651858.CD014547

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  85 in total

1.  A systematic review of the performance of methods for identifying carious lesions.

Authors:  James D Bader; Daniel A Shugars; Arthur J Bonito
Journal:  J Public Health Dent       Date:  2002       Impact factor: 1.821

2.  In Vivo and In Vitro performance of Conventional Methods, DIAGNOdent, and an Electronic Caries Monitor for Occlusal Caries Detection in Primary Teeth.

Authors:  Ebru Kucukyilmaz; Yagmur Sener; Murat Selim Botsali
Journal:  Pediatr Dent       Date:  2015 Jul-Aug       Impact factor: 1.874

3.  The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed.

Authors:  Jonathan J Deeks; Petra Macaskill; Les Irwig
Journal:  J Clin Epidemiol       Date:  2005-09       Impact factor: 6.437

Review 4.  Global burden of untreated caries: a systematic review and metaregression.

Authors:  N J Kassebaum; E Bernabé; M Dahiya; B Bhandari; C J L Murray; W Marcenes
Journal:  J Dent Res       Date:  2015-03-04       Impact factor: 6.116

Review 5.  Direct digital radiography in the dental office.

Authors:  A Wenzel; H G Gröndahl
Journal:  Int Dent J       Date:  1995-02       Impact factor: 2.512

6.  In vivo and in vitro comparison of ICDAS II, DIAGNOdent pen, CarieScan PRO and SoproLife camera for occlusal caries detection in primary molar teeth.

Authors:  A Kockanat; M Unal
Journal:  Eur J Paediatr Dent       Date:  2017-06       Impact factor: 2.231

7.  Longitudinal Study of Caries Development from Childhood to Adolescence.

Authors:  E Hall-Scullin; H Whitehead; K Milsom; M Tickle; T-L Su; T Walsh
Journal:  J Dent Res       Date:  2017-03-06       Impact factor: 6.116

8.  Use of new minimum intervention dentistry technologies in caries management.

Authors:  H Tassery; B Levallois; E Terrer; D J Manton; M Otsuki; S Koubi; N Gugnani; I Panayotov; B Jacquot; F Cuisinier; P Rechmann
Journal:  Aust Dent J       Date:  2013-06       Impact factor: 2.291

9.  Validity of caries detection on occlusal surfaces and treatment decisions based on results from multiple caries-detection methods.

Authors:  Antonio Carlos Pereira; Hafsteinn Eggertsson; Esperanza Angeles Martinez-Mier; Fábio Luiz Mialhe; George Joseph Eckert; Domenick Thomas Zero
Journal:  Eur J Oral Sci       Date:  2009-02       Impact factor: 2.612

10.  Visual or visual-tactile examination to detect and inform the diagnosis of enamel caries.

Authors:  Richard Macey; Tanya Walsh; Philip Riley; Anne-Marie Glenny; Helen V Worthington; Lucy O'Malley; Janet E Clarkson; David Ricketts
Journal:  Cochrane Database Syst Rev       Date:  2021-06-14
View more
  4 in total

1.  Enamel Caries Detection and Diagnosis: An Analysis of Systematic Reviews.

Authors:  T Walsh; R Macey; D Ricketts; A Carrasco Labra; H Worthington; A J Sutton; S Freeman; A M Glenny; P Riley; J Clarkson; E Cerullo
Journal:  J Dent Res       Date:  2021-10-12       Impact factor: 6.116

2.  Deep-learning approach for caries detection and segmentation on dental bitewing radiographs.

Authors:  Ibrahim Sevki Bayrakdar; Kaan Orhan; Serdar Akarsu; Özer Çelik; Samet Atasoy; Adem Pekince; Yasin Yasa; Elif Bilgir; Hande Sağlam; Ahmet Faruk Aslan; Alper Odabaş
Journal:  Oral Radiol       Date:  2021-11-22       Impact factor: 1.882

3.  Dental caries and associated factors among Chinese children and adolescents: A protocol for systematic review and meta-analysis.

Authors:  Zhenxian Huang; Meixuan Su; Qiaojing Wang; Wenjie Li; Haimin Jiang
Journal:  Medicine (Baltimore)       Date:  2021-05-07       Impact factor: 1.889

4.  Visual or visual-tactile examination to detect and inform the diagnosis of enamel caries.

Authors:  Richard Macey; Tanya Walsh; Philip Riley; Anne-Marie Glenny; Helen V Worthington; Lucy O'Malley; Janet E Clarkson; David Ricketts
Journal:  Cochrane Database Syst Rev       Date:  2021-06-14
  4 in total