BACKGROUND: Vagus Nerve Stimulation (VNS) delivers Autonomic Regulation Therapy (ART) for heart failure (HF), and has been associated with improvement in cardiac function and heart failure symptoms. VNS is delivered using an implantable pulse generator (IPG) and lead with electrodes placed around the cervical vagus nerve. Because HF patients may receive concomitant cardiac defibrillation therapy, testing was conducted to determine the effect of defibrillation (DF) on the VNS system. METHODS: DF testing was conducted on three ART IPGs (LivaNova USA, Inc.) according to international standard ISO14708-1, which evaluated whether DF had any permanent effects on the system. Each IPG was connected to a defibrillation pulse generator and subjected to a series of high-energy pulses. RESULTS: The specified series of pulses were successfully delivered to each of the three devices. All three IPGs passed factory electrical tests, and interrogation confirmed that software and data were unchanged from the pre-programmed values. No shifts in parameters or failures were observed. CONCLUSIONS: Implantable VNS systems were tested for immunity to defibrillation, and were found to be unaffected by a series of high-energy defibrillation pulses. These results suggest that this VNS system can be used safely and continue to function after patients have been defibrillated.
BACKGROUND: Vagus Nerve Stimulation (VNS) delivers Autonomic Regulation Therapy (ART) for heart failure (HF), and has been associated with improvement in cardiac function and heart failure symptoms. VNS is delivered using an implantable pulse generator (IPG) and lead with electrodes placed around the cervical vagus nerve. Because HF patients may receive concomitant cardiac defibrillation therapy, testing was conducted to determine the effect of defibrillation (DF) on the VNS system. METHODS: DF testing was conducted on three ART IPGs (LivaNova USA, Inc.) according to international standard ISO14708-1, which evaluated whether DF had any permanent effects on the system. Each IPG was connected to a defibrillation pulse generator and subjected to a series of high-energy pulses. RESULTS: The specified series of pulses were successfully delivered to each of the three devices. All three IPGs passed factory electrical tests, and interrogation confirmed that software and data were unchanged from the pre-programmed values. No shifts in parameters or failures were observed. CONCLUSIONS: Implantable VNS systems were tested for immunity to defibrillation, and were found to be unaffected by a series of high-energy defibrillation pulses. These results suggest that this VNS system can be used safely and continue to function after patients have been defibrillated.
Authors: Clyde W Yancy; Mariell Jessup; Biykem Bozkurt; Javed Butler; Donald E Casey; Mark H Drazner; Gregg C Fonarow; Stephen A Geraci; Tamara Horwich; James L Januzzi; Maryl R Johnson; Edward K Kasper; Wayne C Levy; Frederick A Masoudi; Patrick E McBride; John J V McMurray; Judith E Mitchell; Pamela N Peterson; Barbara Riegel; Flora Sam; Lynne W Stevenson; W H Wilson Tang; Emily J Tsai; Bruce L Wilkoff Journal: Circulation Date: 2013-06-05 Impact factor: 29.690
Authors: Clyde W Yancy; Mariell Jessup; Biykem Bozkurt; Javed Butler; Donald E Casey; Monica M Colvin; Mark H Drazner; Gerasimos S Filippatos; Gregg C Fonarow; Michael M Givertz; Steven M Hollenberg; JoAnn Lindenfeld; Frederick A Masoudi; Patrick E McBride; Pamela N Peterson; Lynne Warner Stevenson; Cheryl Westlake Journal: Circulation Date: 2017-04-28 Impact factor: 29.690
Authors: Rajendra K Premchand; Kamal Sharma; Sanjay Mittal; Rufino Monteiro; Satyajit Dixit; Imad Libbus; Lorenzo A DiCarlo; Jeffrey L Ardell; Thomas S Rector; Badri Amurthur; Bruce H KenKnight; Inder S Anand Journal: J Card Fail Date: 2014-09-01 Impact factor: 5.712
Authors: Marvin A Konstam; James E Udelson; Javed Butler; Helmut U Klein; John D Parker; John R Teerlink; Patricia M Wedge; Benjamin R Saville; Jeffrey L Ardell; Imad Libbus; Lorenzo A DiCarlo Journal: Circ Heart Fail Date: 2019-11-14 Impact factor: 8.790
Authors: Douglas P Zipes; A John Camm; Martin Borggrefe; Alfred E Buxton; Bernard Chaitman; Martin Fromer; Gabriel Gregoratos; George Klein; Arthur J Moss; Robert J Myerburg; Silvia G Priori; Miguel A Quinones; Dan M Roden; Michael J Silka; Cynthia Tracy; Jean-Jacques Blanc; Andrzej Budaj; Veronica Dean; Jaap W Deckers; Catherine Despres; Kenneth Dickstein; John Lekakis; Keith McGregor; Marco Metra; Joao Morais; Ady Osterspey; Juan Luis Tamargo; José Luis Zamorano; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Elliott M Antman; Jeffrey L Anderson; Sharon A Hunt; Jonathan L Halperin; Rick Nishimura; Joseph P Ornato; Richard L Page; Barbara Riegel Journal: Eur Heart J Date: 2006-09 Impact factor: 29.983
Authors: Rajendra K Premchand; Kamal Sharma; Sanjay Mittal; Rufino Monteiro; Satyajit Dixit; Imad Libbus; Lorenzo A DiCarlo; Jeffrey L Ardell; Thomas S Rector; Badri Amurthur; Bruce H KenKnight; Inder S Anand Journal: J Card Fail Date: 2015-11-11 Impact factor: 5.712
Authors: Imad Libbus; Scott R Stubbs; Scott T Mazar; Scott Mindrebo; Bruce H KenKnight; Lorenzo A DiCarlo Journal: J Interv Card Electrophysiol Date: 2021-08-31 Impact factor: 1.759