Colon absorption is a key determinant for the successful development of modified-release (MR) formulations, and the risk that colon absorption may limit the in vivo performance of an MR product can be assessed early by various in vitro tests or by preclinical in vivo regional absorption studies in dogs. Mechanistic physiologically based biopharmaceutics modeling (PBBM) is becoming increasingly accepted to predict in vivo performance and guide formulation development; however, no evaluation of the ability to predict colon absorption has been performed. The purpose of this study was to investigate if regional and colon absorption of drugs in dogs could be predicted with sufficient accuracy using PBBM to enable the replacement of in vivo dog studies in the early assessment of colon absorption limitation risks. This was done by predicting the regional and colon absorption and plasma exposure of 14 drugs after administration to the dog colon according to an a priori approach using the in silico absorption models GI-Sim and GastroPlus. Predictive performance was primarily assessed by comparing observed and predicted plasma concentration-time profiles, AUC0-t, and the relative bioavailability in the colon (Frel,colon) as compared to an oral/duodenal reference. Trends in dependency of prediction performance on predicted fraction absorbed, permeability, and solubility/dissolution rate were also investigated. For GI-Sim, the absolute average fold error (AAFE) values for AUC0-t and Frel,colon were within a 2-fold prediction error for both solutions (1.88 and 1.51, respectively) and suspensions (1.58 and 1.99, respectively). For GastroPlus, the AAFE values for AUC0-t and Frel,colon were outside the set 2-fold prediction error limit for accurate predictions for both solutions (3.63 and 2.98, respectively) and suspensions (2.94 and 2.09, respectively). No trends for over- or underprediction were observed for GI-Sim, whereas GastroPlus showed a slight trend for underprediction of both AUC0-t and Frel,colon for compounds with low permeability. In addition, regional differences in the plasma profiles were qualitatively predicted in the majority of cases for both software. Despite the differences in prediction performance, both models can be considered to predict regional differences in absorption as well as AUC0-t and Frel,colon with acceptable accuracy in an early development setting. The results of this study indicate that it is acceptable to replace in vivo regional absorption studies in dogs with the evaluated models as a method for the early assessment of the risk for colon absorption limitation of MR drug product candidates.
Colon absorption is a key determinant for the successful development of modified-release (MR) formulations, and the risk that colon absorption may limit the in vivo performance of an MR product can be assessed early by various in vitro tests or by preclinical in vivo regional absorption studies in dogs. Mechanistic physiologically based biopharmaceutics modeling (PBBM) is becoming increasingly accepted to predict in vivo performance and guide formulation development; however, no evaluation of the ability to predict colon absorption has been performed. The purpose of this study was to investigate if regional and colon absorption of drugs in dogs could be predicted with sufficient accuracy using PBBM to enable the replacement of in vivo dog studies in the early assessment of colon absorption limitation risks. This was done by predicting the regional and colon absorption and plasma exposure of 14 drugs after administration to the dog colon according to an a priori approach using the in silico absorption models GI-Sim and GastroPlus. Predictive performance was primarily assessed by comparing observed and predicted plasma concentration-time profiles, AUC0-t, and the relative bioavailability in the colon (Frel,colon) as compared to an oral/duodenal reference. Trends in dependency of prediction performance on predicted fraction absorbed, permeability, and solubility/dissolution rate were also investigated. For GI-Sim, the absolute average fold error (AAFE) values for AUC0-t and Frel,colon were within a 2-fold prediction error for both solutions (1.88 and 1.51, respectively) and suspensions (1.58 and 1.99, respectively). For GastroPlus, the AAFE values for AUC0-t and Frel,colon were outside the set 2-fold prediction error limit for accurate predictions for both solutions (3.63 and 2.98, respectively) and suspensions (2.94 and 2.09, respectively). No trends for over- or underprediction were observed for GI-Sim, whereas GastroPlus showed a slight trend for underprediction of both AUC0-t and Frel,colon for compounds with low permeability. In addition, regional differences in the plasma profiles were qualitatively predicted in the majority of cases for both software. Despite the differences in prediction performance, both models can be considered to predict regional differences in absorption as well as AUC0-t and Frel,colon with acceptable accuracy in an early development setting. The results of this study indicate that it is acceptable to replace in vivo regional absorption studies in dogs with the evaluated models as a method for the early assessment of the risk for colon absorption limitation of MR drug product candidates.
Entities:
Keywords:
PBBM; PBPK; colon absorption; drug absorption; in silico prediction; physiologically based biopharmaceutics modeling
Gastrointestinal
(GI) absorption is one of the key factors determining
the in vivo performance of orally administered drugs. GI permeability
and solubility of the drug as well as the dissolution/release rate
from the formulation are the main determinants of the fraction of
the dose absorbed.[1] The small intestine
(SI) is usually viewed as the main site for drug absorption, but for
modified-release (MR) formulations and for drugs with insufficient
SI absorption, absorption from the colon must be considered. Consequently,
it is important to understand the colon absorption for such drug candidates.[2] As the colon is structurally and anatomically
different from the SI, it provides additional barriers against drug
absorption. Differences in permeability between the SI and the colon
due to smaller surface area and tighter junctions in the epithelial
cell layer have been reported and differences in transporter expression
levels may also result in regional permeability differences.[3−5] Furthermore, factors including lower water content, irregular motility,
viscosity, and lack of bile salts are believed to restrict solubility
and dissolution in the colon.[6,7] The distribution of
drug-metabolizing enzymes has also been reported to vary between regions
and drugs may be subject to bacteria-mediated degradation in the colon.[8−10] It is of great importance to understand the impact of regional differences
in intestinal absorption as well as to be able to predict the extent
of absorption from the colon and consequently the in vivo performance
of MR products.[2]The extent of colon
absorption in humans may be assessed directly
by human regional relative bioavailability studies using intubation,
capsule techniques, and colonoscopy techniques.[4,11−14] Usually these studies are performed before initiating MR product
development, but ideally the development risks associated with limited
colon absorption should be assessed early during the candidate selection
or preclinical development phases. Recently, in vivo predictive in
vitro methods such as in vitro permeability assays, simulated biorelevant
colon media for solubility/dissolution investigations as well as colon
stability assays have emerged as tools for the early assessment of
the potential for absorption in the colon.[2,3,9,10,15−17] In addition, it has been demonstrated
that dog colonoscopy and colon stoma models can be predictive of human
colon absorption and permeability, and as a result, the dog is currently
the main preclinical model for the assessment of colon absorption
limitation risks.[5,18−21]Despite recent advancements,
the colon absorption assessment capability
could be further improved. In vivo studies are costly and time consuming,
and in addition, there are ethical aspects to consider for animal
in vivo studies, where the aim should be to remove or replace such
studies with other methodologies when possible. In addition, the available
in vitro methods all have the limitation that they only measure one
parameter in isolation. Recently, the application of mechanistic physiologically
based biopharmaceutics modeling (PBBM)[22] has become increasingly acceptable for predictions of the rate and
extent of absorption. There are several software packages available
for the prediction of intestinal absorption such as GastroPlus, Simcyp,
PK-Sim, and GI-Sim.[23−26] These models integrate anatomical and physiological parameters,
physicochemical properties of the active pharmaceutical ingredient
as well as formulation properties to predict the in vivo performance
of a drug.[27] The models have the advantage
of being able to incorporate all aspects of importance for absorption
thus enabling a potential comprehensive assessment of a drug candidate.
There are several cases where absorption modeling has also been proven
useful to guide MR formulation development.[18,28,29] Furthermore, in silico models of preclinical
species have been used to improve the confidence in predictions of
human regional absorption.[30] To successfully
apply these models in drug development in the absence of any measured
in vivo data, the ability of the in silico models to adequately predict
in vivo performance should first be evaluated. Recently, evaluations
of the predictive performance of several available models with respect
to absorption mainly in the SI have been published.[26,31,32] However, the need for improved colon models
has been identified and an in-depth evaluation of the predictive power
regarding colon absorption has not been published.[2,31,33]The main purpose of this study was
to investigate the ability of
GI-Sim and GastroPlus to predict the regional and colon absorption
of drugs in dogs to evaluate if PBBM approaches could be used to replace
dog in vivo studies in the early assessment of colon absorption limitation
risks. This would in turn reduce the use of animals and enable a more
time and cost-efficient MR product development.
Methods
and Materials
Modeling Strategy
The predictive
performance of the dog colon models in GI-Sim and GastroPlus were
evaluated through predictions of fraction absorbed (fabs), the relative colon bioavailability (Frel,colon), and plasma pharmacokinetic (PK) parameters,
primarily area under the plasma concentration–time curve (AUC),
for a set of model drugs, which have been administered both orally
(or to the duodenum) and directly to the colon in dogs. The study
included simulations of 14 compounds, administered as solutions and/or
suspensions. The absorption modeling was performed according to an
a priori approach where no fitting to observations was allowed, while
the systemic PK input parameters were obtained by compartmental modeling
of intravenous data. An effort was taken to harmonize the input parameters
between the different software. In vivo data from different dog breeds
were used, including data from Beagle, Labrador, and Mongrel dogs.
Investigated Absorption Models
The
two different software evaluated in this study were GastroPlus (version
9.0.0007) and GI-Sim (version 5.2). They both employ a series of coupled
compartments as a model of the GI tract.[23,26] The compartments are defined by parameters such as surface area,
luminal pH, and fluid volume to mimic the physiological environment.
For this evaluation, the fasted Beagle physiology model in GastroPlus
was used, while the fasted Beagle physiology model in GI-Sim was refined
to allow colon absorption modeling (see Section ).
GI-Sim
GI-Sim
is a mechanistic
physiologically based absorption model, which has been internally
developed at AstraZeneca and has been thoroughly described elsewhere.[26] The fasted Beagle physiology in GI-Sim consists
of nine compartments: stomach (1), duodenum (2), jejunum 1 (3), jejunum
2 (4), ileum 1 (5), ileum 2 (6), ileum 3 (7), ileum 4 (8), and colon
(9). For the purpose of this study, the surface area in the colon
compartment in the dog model was derived from the GI-Sim human fasted
model. In the human model, the colonic surface area (including the
cecum) constitutes 3.5% of the total surface area in the GI tract.
Assuming that the same is true for the dog, a colon surface area of
17 cm2 was estimated. This area was not intended to reflect
the true physiological area of the dog colon but rather an initial
estimate of the area available for absorption. The full physiological
model, including the updated surface area, is described in Table . Simulation of absorption
after colon administration was achieved using a dose-to-colon module,
where the drug is administered directly to the colon compartment.
Thus, it was not necessary to adjust the transit times and fluid volumes
in the stomach and the SI compartments. Simulation of reference administrations
to the duodenum was simulated by administration directly to the duodenum
compartment, whereas oral administrations were simulated without any
adjustments to the model. The “solution” and “suspension”
formulation options were selected for solutions and suspensions, respectively.
In accordance to the previously described standard procedure, absorption
in the colon was not allowed for predictions of oral/duodenal (reference)
administrations.[26,31] Since the dose-to-colon option
currently does not allow entry of particle size distribution data,
only mean particle radius was used as input in the GI-Sim predictions.
Table 1
Summary of the Updated Fasted Beagle
Physiology in GI-Sim
GI-compartment
surface
area (cm2)
volume (mL)
transit time (min)
pH
micellar volume fraction
stomach
0
450
15
3.0
0
duodenum
140.6
35.16
15.6
6.2
0.0002
jejunum 1
103.6
25.90
15.6
6.2
0.0002
jejunum 2
76.3
19.08
15.6
6.2
0.0002
ileum 1
56.2
14.06
15.6
6.4
0.0002
ileum 2
41.4
10.36
15.6
6.6
0.0002
ileum 3
30.5
7.632
15.6
6.68
0.0002
ileum 4
22.5
5.621
15.6
6.75
0.0002
colon
17
78.50
720
6.45
0
GastroPlus
GastroPlus (Simulations
Plus, Inc., Lancaster, CA) is based on the advanced compartmental
absorption and transit (ACAT) model and has previously been described
by Agoram et al.[23] The “immediate
release solution” or “immediate release suspension”
dosing options were used for solutions and suspensions, respectively.
For AZ1, particle size was described by fitting a distribution curve
onto the full particle size distribution using 10 particle size bins.
For all other compounds, mean particle size was used as input. The
fasted Beagle physiology in GastroPlus is made up of nine compartments:
stomach (1), duodenum (2), jejunum 1 (3), jejunum 2 (4), ileum 1 (5),
ileum 2 (6), ileum 3 (7), cecum (8), and ascending colon (9). The
physiology is summarized in Table . To simulate administration directly to the colon,
the transit times in compartments 1–7 were set to 0.001 min
and the % fluid in SI was set to 0.1. Oral and duodenal reference
administrations were simulated using default settings or by setting
the transit time in compartment 1 to 0.001 min, respectively.
Table 2
Summary of the Default Fasted Beagle
Physiology in GastroPlus
GI-compartment
length (cm)
radius
(cm)
SEFa
volume (mL)
transit
time (min)
pH
bile salt (mM)
stomach
15.00
1.00
1.000
51.00
15
3.00
0.0
duodenum
12.43
0.62
6.940
6.083
16.8
6.20
5.000
jejunum 1
66.64
0.47
5.905
18.58
51
6.20
4.050
jejunum 2
66.64
0.41
4.161
13.74
37.8
6.20
1.820
ileum 1
1.43
0.47
3.271
0.389
1.2
6.40
0.610
ileum 2
1.43
0.47
3.233
0.396
1.2
6.60
0.440
ileum 3
1.43
0.47
3.196
0.403
1.2
6.68
0.310
cecum
1.99
0.93
1.630
0.538
228.6
6.75
0.0
Asc colon
4.26
1.42
1.700
2.700
491.4
6.45
0.0
Surface area enhancement factor.
Surface area enhancement factor.
Model Drug Selection and
Data Collection
The selection of model drugs in this investigation
was based on
the availability of in vivo data after administration directly to
the colon in dogs. An effort was made to include a broad range of
compounds, covering all four BCS classes. Systemic PK parameters were
estimated by compartmental modeling of the plasma profiles after intravenous
administration using the PK Plus module in GastroPlus (Table ). All plasma concentration
data were gathered either from previously published work or, where
no reference is indicated, from studies performed in house at AstraZeneca.
A general description of the methodology used to investigate the regional
absorption of AZ1, AZ2, and AZ3 in dogs has been described earlier.[5] When intravenous and oral/colon data for a specific
compound were obtained from different dog breeds, the PK parameters
(i.e., clearance and volumes of distribution) were normalized against
body weight to reflect the correct breed in the predictions of exposure
after oral/colon administrations. The same PK parameters were used
as input in GI-Sim to avoid potential differences in PK algorithms.
The first-pass liver extraction was estimated bywhere EH is the
hepatic extraction ratio, CLH the hepatic clearance, QH the hepatic blood flow (39.6 L/h for a 12
kg dog), and B/P is the blood:plasma concentration ratio (B/P = 1
in all simulations). CLH was assumed to be equal to nonrenal
clearance and was calculated by CL = CLH + CLR. CLR was estimated by fu × GFR, where fu is the
fraction unbound and GFR is the glomerular filtration rate, which
was assumed to be 61.3 mL/min for a 12 kg dog. Where no values for
fu were available (ketoprofen and enalaprilat), CLR was
assumed to be zero. For metoprolol, the estimated CLR using
the abovementioned strategy generated first-pass values above 100%.
For this reason, QH was normalized against
the weight of 30 kg dog, and this value (99 L/h) was used to estimate
the first-pass extraction of metoprolol. For theophylline, the calculated
CLR was higher than the total CL generated by compartmental
modeling of the available in vivo data, and in this case, CLR was set at zero for the purpose of the simulations. Biopharmaceutics
and physicochemical properties of the drugs were gathered from previously
published reports or internal measurements at AstraZeneca (Table ). In vitro solubility
in buffer and fasted simulated small intestinal fluid (FaSSIF) were
used when available. Solubility was assumed to be the same in FaSSIF
as in buffer when no biorelevant solubility was available, i.e., no
partitioning into micelles was assumed. Missing particle size data
was handled by assuming a mean particle diameter of 20 μm as
previously described.[26,31] Molar density (ρ) was calculated
by ρ =MW/VM, where MW is the
molecular weight and VM is the molar volume.
The diffusion coefficient in water (D) was estimated
by Stoke–Einstein’s equationwhere k is the Boltzmann’s
constant, T is the absolute temperature, η
is the viscosity of water, and r is the molecule
radius. Missing data on ρ or D were handled
using default values of 1.2 g/mL and 0.76 × 10–9 m2/s, respectively, as previously described.[26,31] The effective permeability (Peff) in
dogs was estimated as described below.
Table 3
Systemic
Compartmental Pharmacokinetic
Parameters and Fraction Lost during First-Pass Used in the Simulations
CL (L/h/kg)
V (L/kg)
k12 (h–1)
k21 (h–1)
k13 (h–1)
k31 (h–1)
fua
first-pass
extraction (%)
Aprepitant
0.09
0.204
6.887
2.722
n/a
n/a
0.014
2.74
Atenolol
0.268
0.97
1.29
0.584
n/a
n/a
0.9
3.45
AZ1
0.467
0.116
27.82
6.96
4.839
1.039
0.063
35.35
AZ2
0.086
0.366
0.073
0.011
n/a
n/a
n/a
2.59
AZ3
0.624
0.364
7.153
2.369
n/a
n/a
0.0022
47.25
Cimetidine[35]
0.714
0.424
5.909
3.472
0.218
0.323
0.9
21.12
Enalaprilat
0.155
0.751
1.149
0.338
n/a
n/a
n/a
0.47
Felodipine[36]
1.142
0.65
n/a
n/a
n/a
n/a
0.001
40.53
Ketoprofen
0.146
0.158
2.018
1.76
0.394
0.188
n/a
11.03
Metoprolol
2.643
8.92
n/a
n/a
n/a
n/a
0.85
53.0
Nifedipine[37]
2.638
1.368
2.709
0.69
n/a
n/a
0.076
79.95
Propranolol[38]
0.934
1.087
5.828
2.782
1.887
0.09
0.19
62.0
Ranitidine[39]
0.60
0.13
7.942
1.215
0.289
0.141
0.71
13.69
Theophylline[40]
0.083
0.558
n/a
n/a
n/a
n/a
0.85
2.51
Fraction
unbound used in simulations.
Table 4
Biopharmaceutics and Physicochemical
Input Parameters of the Model Compounds Included in the Evaluation
Mw (g/mol)
pKaa
log D7.4
ρ (g/mL)
particle radiusb (μm)
D (10–9·m2/s)
Peff,dogc (10–4·cm/s)
Sbuffer (pH) (μg/mL)
SFaSSIF (μg/mL)
BCS
Aprepitant
534
9.15 a
6.9[31]
1.51[31]
0.12
0.63[31]
7.1[31]
0.37 (6.5)[31]
23[31]
II
2.4 b[31]
Atenolol
266
9.21 b[26]
–2[5]
1.1
0.72[26]
0.82[5]
13 300 (intrinsic)[2]
13 300d
III
AZ1
450 ± 5
12 a
2.9
1.38
25
0.68
4.16
8.9 (6.5)
17
II
2.2 b
AZ2
400 ± 5
11 a
1.36
1.38
5
0.68
3.92
253 (6.5)
253
IV
AZ3
520 ± 5
3.05 b
3.89
1.24
5
0.60
6.9
7 (7.4)
360
IV
Cimetidine
252
6.76 b[26]
0.23
1.15
0.77[26]
1.03[26]
24 000 (6.8)[2]
24 000d
III
Enalaprilat
348
7.84 a
–1[5]
0.69[26]
0.82[5]
5000 (water)[41]
5000d
III
3.17 b[5]
Felodipine
384
neutral[31]
4.3[31]
1.28[31]
0.67[31]
7.7[31]
1 (6.5)[31]
53[31]
II
Ketoprofen
254
4.02 a[26]
0.1[5]
1.14
0.75[26]
8.7[26]
51 (1.2)[42]
51d
II
Metoprolol
267
9.18
b[26]
0[5]
1.07
0.71[26]
4.83[26]
43 000 (6.5)[2]
43 000d
I
Nifedipine
346
neutral[20]
2.07[20]
3.6[43]
11 (6.5)[20]
17[43]
II
Propranolol
259
9.4
b[20]
1.16
0.72[26]
2.91[26]
1000 (6.5)[20]
1000d
I
Ranitidine
351
7.62 b
–0.94
1.15
0.69[26]
0.80[44]
1750 (7.4)
1750d
III
2.22 b
Theophylline
180
8.4 a
–0.14
1.25
0.85
7.2
1800 (7.4)
1800d
I
For pKa values, the
notations a and b represent acid and base, respectively.
Particle size is presented as a
mean particle radius. For AZ1, the full particle size distribution
was used as input in the models.
Estimated dog Peff applied in the simulations.
The same value as Sbuffer due to the lack of FaSSIF solubility data.
Fraction
unbound used in simulations.For pKa values, the
notations a and b represent acid and base, respectively.Particle size is presented as a
mean particle radius. For AZ1, the full particle size distribution
was used as input in the models.Estimated dog Peff applied in the simulations.The same value as Sbuffer due to the lack of FaSSIF solubility data.
Strategy to Estimate
the Effective Permeability
in Dogs
Since dog intestinal Peff values are rarely available and there is no well-established correlation
between dog and human Peff, three different
strategies were evaluated to estimate Peff in dog in this study:The first approach assumed that Peff is the same in dogs and humans for all compounds.The second approach used the correlation
incorporated in GI-Sim, which assumes that Peff in dogs is approximately 3 times higher than the human Peff. In GastroPlus, the dog Peff is approximately 2.4–3-fold higher than the
human Peff, depending on the permeability
input value. Therefore, approach 2 was considered to be representable
for the default settings in GastroPlus.The third strategy divided the compounds
into two groups based on previous work by Dahlgren et al.[5] Their results indicate that Peff is higher in dog for low-permeability compounds, but
that Peff is similar in dogs and humans
for high-permeability compounds.[5] In this
evaluation, a limit was set at a human Peff of 1.34 (human Peff of the high-permeability
marker metoprolol). Compounds with a Peff lower or equal to 1.34 were assumed to follow the GI-Sim correlation
of having a 3-fold higher permeability in dogs. Compounds with a Peff above 1.34 were assumed to have the same Peff in dogs and humans.Previously measured or estimated human Peff values were used as a basis for all three approaches.
Where no Peff values were available, apparent
permeability (Papp) in Caco-2 cell lines
were used to predict human Peff according
to a previously established Caco-2 Papp–human Peff correlation. The different
approaches were evaluated in initial simulations of 15 compounds after
oral and colon administrations in GI-Sim only. A strategy was chosen
based on the ability to predict area under the plasma concentration–time
curve up to the last measured concentration (AUC0-), peak plasma concentration (Cmax), and time to peak plasma concentration (tmax) and was used for the full evaluation in both software.
Prediction Performance Assessment
The evaluation of the ability of the models to predict the extent
of absorption in the colon was primarily based on the ability to predict
the mean AUC0- and the relative
bioavailability after administration to the colon (Frel,colon) in comparison to oral/duodenal administration
(AUCcolon/AUCref). The predicted fraction absorbed
in the colon (fabs,colon) was also noted
for each simulation. The absolute average fold error (AAFE) was used
as a measure of the overall predictive accuracy.Using the ratio
of absolute predicted and
observed values, over- and underpredictions will not cancel each other
out and AAFE will consequently serve as a measure of the overall accuracy.
To assess the tendency for over- or underprediction, the average fold
error (AFE) was used.AFE values
below 1 indicate a trend for underprediction,
whereas values above 1 indicate overprediction. A model with perfect
accuracy and no systematic trend for over- or underprediction would
hence have both AAFE and AFE values of 1. A AAFE ≤ 2, i.e.,
a 2-fold prediction error, was defined as accurate in this evaluation,
which is in accordance with the prediction criteria for other PK parameters
at the stage of development as considered here.[34] Furthermore, the percentage of the predictions within 2-fold
of the observations were documented.Results were examined to
discover any trends in the predictive performance depending on Peff, solubility, or predicted fabs, colon.
Results
Selection of Strategy to Estimate Peff in Dogs
Out of the three evaluated
strategies to estimate Peff in dogs, the
strategy which divided the compounds into two different groups according
to permeability class was found to be somewhat better than the other
approaches and was selected for estimation of dog Peff throughout the remainder of the study (AAFEAUC = 1.84, AFEAUC = 1.08). The strategy assuming dog Peff = human Peff resulted in a tendency for underprediction of AUC (AAFEAUC = 2.30, AFEAUC = 0.78), whereas the strategy assuming
3-fold higher Peff in dogs compared to
humans regardless of permeability class resulted in a tendency for
overprediction (AAFEAUC = 2.10, AFEAUC = 1.54).
The estimated dog Peff values used in
the final simulations are summarized in Table .
Evaluation of Colon Absorption
Prediction
Performance
GI-Sim and GastroPlus were primarily evaluated
with respect to their ability to predict AUC0-, and Frel,colon after
administration to the colon in dog, but also with regards to Cmax and tmax. Thirteen
of the 14 model drugs were administered to the colon as a solution,
while colon absorption data for suspensions were available for six
of the model drugs. The observed and predicted plasma concentration–time
profiles after oral/duodenal and colon administration are shown in Figures and 2 for GI-Sim and GastroPlus, respectively. A summary of observed
and predicted data is presented in Table . The overall predictive performance of both
software is summarized in Table and Figure .
Figure 1
Mean observed and predicted plasma concentration–time profiles
after oral/duodenal and colon administration using GI-Sim. Observed
data is depicted with symbols and predicted data with solid lines.
No observed plasma concentration–time profiles were available
for theophylline, nifedipine, and propranolol.
Figure 2
Mean observed
and predicted plasma concentration–time profiles
after oral/duodenal and colon administration using GastroPlus. Observed
data is depicted with symbols and predicted data with solid lines.
No observed plasma concentration–time profiles are available
for theophylline, nifedipine, and propranolol.
Table 5
Observed and Predicted Dog Colon Absorption
Parameters of the Model Drugs in Relation to Dose and Formulation
Type Applied in the Simulations
AUC0-ta (μg × h/mL)
AUC0-t,predb (μg × h/mL)
Frel, colonc
Frel,colon,predd
fabs,colon,prede
drug
dose (mg)
formulation
obs
GIS
G+
obs
GIS
G+
GIS
G+
Aprepitant[45]
24
nanosuspension
1.01
0.24
21.5
0.04
0.02
1.00
1.6
100.0
Atenolol[5]
5
solution
0.06
0.04
0.00
0.27
0.21
0.01
23.1
3.0
AZ1
30
solution
0.94
1.10
0.98
0.46
0.80
0.71
79.6
71.7
AZ1
40
suspension
0.22
0.23
0.53
0.20
0.35
0.41
13.6
30.2
AZ2
15
solution
2.76
3.52
4.21
0.61
0.78
0.94
78.6
94.6
AZ2
20
suspension
4.76
4.68
5.23
1.05
1.05
1.17
78.4
88.4
AZ3
75
solution
0.46
1.83
1.53
0.23
0.91
0.73
86.6
72.9
AZ3
75
suspension
0.38
0.18
0.50
0.19
0.09
0.24
9.1
25.9
Cimetidine
87
solution
3.55
1.00
1.09
0.68
0.52
0.50
46.2
50.2
Enalaprilat[5]
20
solution
0.12
0.24
0.05
0.43
0.23
0.05
25.6
10.2
Felodipine
10
solution
0.03
0.17
0.37
0.39
0.93
0.86
87.8
86.1
Felodipine
10
suspension
0.02
0.02
0.13
0.27
0.09
0.30
9.1
30.1
Ketoprofen[5]
2.5
solution
0.29
0.32
0.36
0.82
0.83
0.96
89.6
99.2
Metoprolol[5]
12.5
solution
0.04
0.05
0.03
0.75
0.60
0.52
73.7
70.4
Nifedipine[20]
24
solution
0.16
0.12
0.07
0.93
0.78
0.49
77.1
50.3
Nifedipine[20]
12
suspension
0.04
0.03
0.02
0.35
0.73
0.30
22.7
17.2
Propranolol[20]
48
solution
4.51
1.27
1.15
0.98
0.67
0.58
70.7
64.1
Ranitidine
63
solution
1.33
0.81
0.05
0.42
0.46
0.02
38.9
2.7
Theophylline20
120
solution
104
98.8
66.7
0.81
0.86
0.59
87.1
62.8
Area under the
curve between time
zero and the last observed time point.
Predicted area under the curve between
time zero and the last observed time point.
Relative bioavailability after administration
to colon as compared to oral/duodenal administration.
Predicted relative bioavailability
after administration to colon as compared to oral/duodenal administration.
Predicted fraction absorbed
in colon.
Table 6
Summary
of the Predictive Performance
of GI-Sim and GastroPlus After Colon Administration in Dogsa
% predictions (n) within 2-fold
deviation
AAFE
AFE
solutions
GI-Sim
69 (9)
1.88
1.04
AUC
GastroPlus
38 (5)
3.63
0.54
suspensions
GI-Sim
67 (4)
1.58
0.64
GastroPlus
50 (3)
2.94
2.59
solutions
GI-Sim
85 (11)
1.51
1.10
Frel
GastroPlus
54 (7)
2.98
0.53
suspensions
GI-Sim
33
(2)
1.99
0.77
GastroPlus
67 (4)
2.09
1.99
Results are shown
as a percentage
of simulations that fall within each specific accuracy level, as well
as the absolute average fold error (AAFE) and average fold error (AFE).
Figure 3
Colon
absorption prediction performance of Frel,colon, AUC0-, Cmax, and tmax for
solutions (blue triangles) and suspensions (green diamonds) after
direct administration to the colon in dogs. GI-Sim results are displayed
in the left column and GastroPlus in the right column. The solid line
is the line of unity and the dotted lines represent a 2-fold deviation.
Mean observed and predicted plasma concentration–time profiles
after oral/duodenal and colon administration using GI-Sim. Observed
data is depicted with symbols and predicted data with solid lines.
No observed plasma concentration–time profiles were available
for theophylline, nifedipine, and propranolol.Mean observed
and predicted plasma concentration–time profiles
after oral/duodenal and colon administration using GastroPlus. Observed
data is depicted with symbols and predicted data with solid lines.
No observed plasma concentration–time profiles are available
for theophylline, nifedipine, and propranolol.Colon
absorption prediction performance of Frel,colon, AUC0-, Cmax, and tmax for
solutions (blue triangles) and suspensions (green diamonds) after
direct administration to the colon in dogs. GI-Sim results are displayed
in the left column and GastroPlus in the right column. The solid line
is the line of unity and the dotted lines represent a 2-fold deviation.Area under the
curve between time
zero and the last observed time point.Predicted area under the curve between
time zero and the last observed time point.Relative bioavailability after administration
to colon as compared to oral/duodenal administration.Predicted relative bioavailability
after administration to colon as compared to oral/duodenal administration.Predicted fraction absorbed
in colon.Results are shown
as a percentage
of simulations that fall within each specific accuracy level, as well
as the absolute average fold error (AAFE) and average fold error (AFE).For solutions in GI-Sim, the
AAFE values for AUC0- and Frel,colon were
both within a 2-fold prediction error (1.88 and 1.51, respectively)
and there was no trend for over-/underprediction with corresponding
AFE values of 1.04 and 1.10, respectively (Table ). The predictions of AUC0- and Frel,colon were
within a 2-fold deviation from the observed values in 69 and 85% of
the cases, respectively, for the solutions (Table ). Similarly, for suspensions, the AAFE values
for both AUC0- and Frel,colon were within a 2-fold prediction error (1.58
and 1.99, respectively), but the corresponding AFE values of 0.64
and 0.77 indicated a trend for underprediction (Table ). The predictions of AUC0- for the suspensions were within a 2-fold deviation
from the observed values in 67% of the cases, while Frel,colon predictions were only within that range for
33% of the cases (Table ). Predictions of Cmax and tmax were within a 2-fold deviation from the observed values
in more than 50% of the cases for solutions (Figure ). For suspensions, Cmax tended to be underpredicted whereas tmax was generally overpredicted (Figure ). Overall, the simulated and observed plasma
profiles (Figure )
agreed well and regional differences in absorption were adequately
captured in the simulations. However, the plasma exposure after colon
administration of solutions of the low-solubility drugs AZ1, AZ3,
and felodipine was overpredicted.For solutions in GastroPlus,
the AAFE values for AUC0- and Frel,colon were
both outside the set 2-fold prediction error limit (3.63 and 2.98,
respectively) and the corresponding AFE values were 0.54 and 0.53,
which indicated a trend for underprediction (Table ). The predictions of AUC0- and Frel,colon were
within a 2-fold deviation from the observed values in 38 and 54% of
the cases, respectively, for the solutions (Table ). For the suspensions, the AAFE values for
AUC0- and Frel,colon were 2.94 and 2.09, respectively, and the corresponding
AFE values were 2.59 and 1.99, which indicated a trend for overprediction
(Table ). AUC0- and Frel,colon were predicted within a 2-fold deviation from the observed value
in 50 and 67% of the cases (Table ). For suspensions, Cmax was predicted within a 2-fold deviation from the observed values
in 50% of the cases with no trend for over- or underprediction, whereas Cmax for solutions was only within a 2-fold deviation
from the observed values in 23% of the cases. Tmax was generally overpredicted for both solutions and suspensions
(Figure ).Any
trends in prediction performance in relation to the predicted fabs,colon, Peff,
or dose/solubility ratio were also investigated (Figures and 5). For GI-Sim, there
was no observed dependency between the prediction accuracy of the
solutions or suspensions and the predicted fabs,colon, even though the predicted fabs,colon was significantly lower for the suspensions. For
GastroPlus, there was a trend for decreased prediction accuracy of
the solutions at lower Peff and predicted fabs,colon.
Figure 4
Accuracy of predicted Frel,colon and
AUC0- plotted in relation to the
predicted fabscolon for solutions (blue
triangles) and suspensions (green diamonds). GI-Sim results are depicted
in the left column and GastroPlus in the right column. The solid line
is the line of unity and the dotted lines represent a 2-fold deviation.
Accuracy of predicted Frel,colon and
AUC0- plotted in relation to the
predicted fabscolon for solutions (blue
triangles) and suspensions (green diamonds). GI-Sim results are depicted
in the left column and GastroPlus in the right column. The solid line
is the line of unity and the dotted lines represent a 2-fold deviation.
Discussion
The main
purpose of this study was to evaluate how well the regional
and colon absorption in dogs could be predicted by mechanistic PBBM
using GI-Sim and GastroPlus. Regional absorption studies in dogs are
performed as a surrogate for a corresponding human study for the early
assessment of the extent of colon absorption, which is a critical
parameter for the successful development of MR formulations. Ideally,
the in vivo model would be replaced by a mechanistic in silico absorption
model to reduce the use of animals and enable a more time and cost-efficient
MR formulation development. However, this requires that the ability
of the model to accurately predict regional/colon absorption, both
qualitatively and quantitatively, is demonstrated. This was done by
modeling the absorption and plasma profiles of 14 compounds with available
in vivo regional and colon absorption data using an a priori approach
without any fitting to observed data to reflect the real situation.
Also, the evaluation was subdivided according to the formulation type,
i.e., into solutions and suspensions, to investigate how permeability
and solubility/dissolution rate affected the prediction performance
of the models.The extent of colon absorption of solutions was
considered to be
predicted with a sufficient degree of accuracy by GI-Sim since the
predefined limit for accurate predictions (AAFE ≤ 2) was met
and since no trend for over-/underprediction was observed. In addition,
the predictive performance was not dependent on the predicted fabs or the Peff used
(Figures and 5A,C). For GastroPlus, the limit for accurate predictions
was not met for either AUC0- or Frel,colon. The somewhat lower prediction accuracy
was mainly related to an underprediction of fabs,colon for the compounds with lower permeability, including
atenolol, ranitidine, and enalaprilate. This demonstrates that the
two software differ even though the overall model structure is the
same. For example, in GastroPlus, the lipophilicity (Log D
and log P) is taken into account when the Peff in each compartment is calculated while GI-Sim only
considers the unionized fraction.[23,26] Changes in
the colon absorption scale factors may be considered to improve the
prediction accuracy for low-permeability drugs in GastroPlus, but
such an evaluation was out of scope for this study. Furthermore, both
GastroPlus and GI-Sim overpredicted the colon absorption for the solutions
of the poorly soluble drugs AZ1, AZ3, and felodipine, which could
be due to the fact that precipitation may have occurred in vivo as
described earlier by Sutton.[20] If such
information would have been available and accounted for in the modeling,
the observed prediction performance might have been improved for both
software.
Figure 5
Accuracy of predicted Frel,colon and
AUC0- in relation to Peff or dose/solubility ratio for solutions and suspensions.
GI-Sim results are represented by black triangles (solutions) and
squares (suspensions) and GastroPlus results by open triangles (solutions)
and squares (suspensions). The solid line is the line of unity and
the dotted lines represent a 2-fold deviation.
Accuracy of predicted Frel,colon and
AUC0- in relation to Peff or dose/solubility ratio for solutions and suspensions.
GI-Sim results are represented by black triangles (solutions) and
squares (suspensions) and GastroPlus results by open triangles (solutions)
and squares (suspensions). The solid line is the line of unity and
the dotted lines represent a 2-fold deviation.The extent of colon absorption of suspensions was considered to
be predicted with a sufficient degree of accuracy by GI-Sim since
the predefined limit for accurate predictions (AAFE ≤ 2) was
met for both AUC0- and Frel,colon, but with a slight trend for underprediction.
The low number of compounds administered as a suspension made it more
difficult to detect any clear trends, but GI-Sim may potentially underpredict
both AUC0- and Frel,colon of low-solubility compounds (high dose/solubility
ratios). For GastroPlus, the AAFE values for AUC0- and Frel,colon were
2.94 and 2.09, respectively, and both parameters were generally overpredicted.
Part of the reason for these values was the large overprediction of
the extent of colon absorption of aprepitant. This compound differed
from the others as it was administered as a nanosuspension, which
is more complex to model. Aprepitant was better predicted by GI-Sim,
which is in line with previous studies demonstrating the ability of
GI-Sim to predict increases in absorption and exposure achieved with
nanoformulations of poorly soluble drugs.[26] Furthermore, the prediction accuracy of GastroPlus did not seem
to be dependent on the dose/solubility ratio. Some additional considerations
should be taken into account regarding the prediction accuracy for
the suspensions. In some cases, Frel,colon of the suspension was calculated using data for an oral solution
as reference, which does not accurately reflect the difference of
a suspension administered orally as compared to colon. Second, the
compounds administered as suspensions in this study were all low-solubility
compounds, making modeling of the dissolution process particularly
challenging[46]In an early risk assessment
setting, the main purpose is to be
able to predict potential limitations in colon absorption. Hence,
even where a quantitatively accurate prediction of exposure after
administration to the colon is not achieved, the ability to qualitatively
predict differences in regional absorption should be considered enough
to enable this risk assessment. Although there were some differences
in the prediction performance between GI-Sim and GastroPlus, where
the AAFE criteria were not met by GastroPlus, overall both models
were able to predict regional differences in absorption as well as
the AUC0- and Frel,colon with acceptable accuracy in the majority of
cases. It should also be taken into consideration that in this evaluation,
the intention was to make the simulation conditions as similar as
possible in both software. The applied methodology may not be optimal
for any of the investigated software but reflects the effort to generate
comparable results. With all of this in mind, the results suggest
that it may indeed be possible to replace in vivo regional absorption
studies in dogs in the early assessment of the risk for colon absorption
limitation with the evaluated models.One critical step in the
modeling strategy was the selection of
permeability value in dogs. Even though dog Peff values have been published for some of the compounds included
in this study,[5] this is generally not the
case. Both GI-Sim and GastroPlus have built-in human Peff–dog Peff correlations,
but the accuracy of the available correlations is not well-established.
Therefore, in this study, three general approaches to estimate dog Peff were evaluated and the approach, dividing
the compounds into two groups depending on the human permeability
class, was the most successful. The defined limit of a human Peff of 1.34 (Peff for metoprolol) was based on a work by Dahlgren et al., where they
measured Peff indirectly in dogs with
intestinal stomas and presented data showing a higher permeability
in dogs in comparison to humans for the low-permeability compound
atenolol, whereas the high-permeability compounds metoprolol and ketoprofen
had similar Peff values in dogs and human.[5] Although the exact limit is somewhat arbitrary,
one could argue that, out of the approaches examined here, this is
the most scientifically sound approach based on available data. Considering
physiological differences in the GI tract, it is plausible that compounds
with low permeability in humans may be better absorbed in dogs due
to increased possibilities for paracellular transport.[47−49] However, when passive transcellular permeability is already sufficiently
high in humans, the larger paracellular pores in the dogs play a minor
quantitative role. Overall, it was concluded that, since this approach
offered the best predictive performance and was considered mechanistically
sound, it was used to estimate dog Peff throughout this study.Despite the encouraging results obtained
in this study, the predictive
performance of GI-Sim and GastroPlus could be further improved. In
addition to improving the estimation of the dog Peff discussed above, the physiological relevance could
be increased. For example, the scaling of the surface area available
for absorption in the colon in GI-Sim should ideally be derived from
the understanding of the dog colon physiology rather than scaled from
the human model. The dog colon is known to be substantially shorter
than the human colon and a direct adaption from the human model might
not be appropriate.[50] The SI part of the
GI-Sim dog model could also be modified to more accurately reflect
the physiology of the dogGI tract. It has been proposed that a more
appropriate model should have a larger number of jejunal compartments
to reflect the fact that dogs have a proportionally longer jejunum
and shorter ileum than humans.[51,52] However, this was out
of scope for this study.In this evaluation, care was taken
to ensure the use of high-quality
input data when available but since data was gathered from many different
sources there is a significant source of variability in how the data
was generated. Additionally, data was gathered from different dog
breeds, but all simulations were performed using a Beagle model, which
is the only dog model available in GI-Sim and GastroPlus. However,
physiologies differ between different breeds and this could affect
the quality of the output.[53] Furthermore,
data on mean particle size was lacking in some cases and full particle
size distribution data was only available for AZ1. It is possible
that more accurate predictions could have been obtained for some of
the suspensions if this data had been available. Finally, it should
be pointed out that the built-in human–dog Peff conversion in GastroPlus was not tested in this study,
but this is anticipated to have no or minor effects on the obtained
results. An in-depth evaluation of the reasons for any difference
in the prediction performance between the different models was beyond
the scope of this evaluation.
Conclusions
This
study shows that mechanistic PBBM approaches can be used to
predict regional differences in absorption as well as the extent of
colon absorption in dogs with acceptable accuracy. This indicates
that it is possible to replace in vivo regional absorption studies
in dogs with in silico mechanistic biopharmaceutics modeling using
GI-Sim or GastroPlus in the early assessment of the risk for colon
absorption limitation, which in turn facilitate early decisions to
initiate MR product development or not. Furthermore, the data set
used in this study is now available to use for further improvement
of the in silico dog colon absorption models.
Authors: Tiago Sousa; Ronnie Paterson; Vanessa Moore; Anders Carlsson; Bertil Abrahamsson; Abdul W Basit Journal: Int J Pharm Date: 2008-07-16 Impact factor: 5.875
Authors: Maria Vertzoni; Amalia Diakidou; Manos Chatzilias; Erik Söderlind; Bertil Abrahamsson; Jennifer B Dressman; Christos Reppas Journal: Pharm Res Date: 2010-07-30 Impact factor: 4.200