Literature DB >> 3371485

Reduction of postoperative pelvic adhesions in the rabbit with Gore-Tex surgical membrane.

S P Boyers1, M P Diamond, A H DeCherney.   

Abstract

Gore-Tex (W.L. Gore and Associates, Inc., Flagstaff, AZ) surgical membrane (SM), a nonreactive expanded polytetrafluoroethylene (PTFE), was used in 24 mature New Zealand rabbits (2200 to 3000 gm) to cover 2-cm2 ischemic defects in the pelvic sidewall peritoneum to reduce adhesion formation in a rabbit pelvic sidewall/uterine horn injury model. SM was randomly assigned to cover one defect; the opposite defect remained uncovered, each animal serving as its own control. Rabbits were sacrificed 3 weeks later, and adhesions between uterine horn and pelvic sidewall or SM were scored for extent (0 to 4), type (0 to 4), and tenacity (0 to 3). Injury sites were removed en bloc for histologic study. The mean (+/- standard deviation [SD]) adhesion score for SM-covered lesions (4.3 +/- 1.8) was significantly lower than for controls (9.1 +/- 2.5) (P less than 0.001; Wilcoxon Signed Rank test). By histology, none of 24 SM-covered lesions demonstrated adhesions to the membrane itself, whereas 19 of the 24 control lesions showed dense adhesions to the injury site (P less than 0.001; chi-square test). By both gross and microscopic assessment, SM was nonadherent to the underlying sidewall defect in 100% of cases. In conclusion, Gore-Tex surgical membrane is an effective barrier for reducing primary adhesions in this pelvic injury model and offers promise for adhesion reduction in human pelvic surgery.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3371485     DOI: 10.1016/s0015-0282(16)59962-2

Source DB:  PubMed          Journal:  Fertil Steril        ISSN: 0015-0282            Impact factor:   7.329


  3 in total

Review 1.  A review of the management of small bowel obstruction. Members of the Surgical and Clinical Adhesions Research Study (SCAR).

Authors:  M S Wilson; H Ellis; D Menzies; B J Moran; M C Parker; J N Thompson
Journal:  Ann R Coll Surg Engl       Date:  1999-09       Impact factor: 1.891

2.  Evaluation of DualMesh for repair of large hiatus hernia in a porcine model.

Authors:  G S Smith; E J Hazebroek; R Eckstein; H Berry; W M Smith; J R Isaacson; G L Falk; C J Martin
Journal:  Surg Endosc       Date:  2007-11-14       Impact factor: 4.584

3.  Prevention of de novo adhesion by ferric hyaluronate gel after laparoscopic surgery in an animal model.

Authors:  Romain Detchev; Marc Bazot; David Soriano; Emile Daraï
Journal:  JSLS       Date:  2004 Jul-Sep       Impact factor: 2.172

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.