Literature DB >> 33714441

One-step, wash-free, bead-based immunoassay employing bound-free phase detection.

Benita Johannsen1, Michal Karpíšek2, Desirée Baumgartner3, Vanessa Klein4, Nagihan Bostanci5, Nils Paust6, Susanna M Früh6, Roland Zengerle6, Konstantinos Mitsakakis7.   

Abstract

We present a simple and fast one-step heterogeneous immunoassay, with performance characteristics that can enable easy and versatile adaptation to miniaturized, automated point-of-care systems. This novel analytical method uses magnetic and fluorescent beads as capture and detection agents respectively. Its main feature is the measurement of the fluorescent signal in the bound-free phase for (semi-)quantitative detection of analytes. Thus, no washing is required and the workflow consists only of sample and reagent supply, incubation, separation and detection. The immunoassay concept is demonstrated with C-reactive protein (CRP), a systemic inflammation marker. CRP in only 5 μL of undiluted serum was measured in the range 20-140 mg L-1 (includes clinically relevant cut-off values). The limit of detection (LOD) was 22.1 ± 6.3 mg L-1 (incubation 15 min). A CRP certified reference material was measured on five different days. Intra- and inter-assay coefficients of variation were 4.6 ± 1.9% and 5.6% respectively. To demonstrate the compatibility of the assay concept with additional matrices and concentration ranges, three oral inflammation markers, namely matrix metalloproteinases 8 and 9 (MMP-8, MMP-9) and tissue inhibitor of metalloproteinases 1 (TIMP-1), were measured in saliva in the ranges 0.47-30 ng mL-1 for MMP-8 and MMP-9, and 0.69-44 ng mL-1 for TIMP-1. LODs were 0.24 ng mL-1, 0.38 ng mL-1 and 0.39 ng mL-1 respectively (incubation 20 min). Multiplexing capacity of the assay concept was also shown with these markers. The demonstrated excellent reproducibility of the results, combined with the versatility and low complexity of the introduced immunoassay concept, make it an attractive candidate for applied analytical chemistry and automated point-of-care testing.
Copyright © 2021 The Author(s). Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bound-free phase; Immunoassay; Inflammation; Micro/nanoparticles; Oral biomarkers; Saliva

Mesh:

Substances:

Year:  2021        PMID: 33714441     DOI: 10.1016/j.aca.2021.338280

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Bead Number Effect in a Magnetic-Beads-Based Digital Microfluidic Immunoassay.

Authors:  Wensyang Hsu; Yu-Teng Shih; Meng-Shiue Lee; Hong-Yuan Huang; Wan-Ning Wu
Journal:  Biosensors (Basel)       Date:  2022-05-16

2.  ImmunoDisk-A Fully Automated Bead-Based Immunoassay Cartridge with All Reagents Pre-Stored.

Authors:  Benita Johannsen; Desirée Baumgartner; Lena Karkossa; Nils Paust; Michal Karpíšek; Nagihan Bostanci; Roland Zengerle; Konstantinos Mitsakakis
Journal:  Biosensors (Basel)       Date:  2022-06-14

3.  OralDisk: A Chair-Side Compatible Molecular Platform Using Whole Saliva for Monitoring Oral Health at the Dental Practice.

Authors:  Desirée Baumgartner; Benita Johannsen; Mara Specht; Jan Lüddecke; Markus Rombach; Sebastian Hin; Nils Paust; Felix von Stetten; Roland Zengerle; Christopher Herz; Johannes R Peham; Pune N Paqué; Thomas Attin; Joël S Jenzer; Philipp Körner; Patrick R Schmidlin; Thomas Thurnheer; Florian J Wegehaupt; Wendy E Kaman; Andrew Stubbs; John P Hays; Viorel Rusu; Alex Michie; Thomas Binsl; David Stejskal; Michal Karpíšek; Kai Bao; Nagihan Bostanci; Georgios N Belibasakis; Konstantinos Mitsakakis
Journal:  Biosensors (Basel)       Date:  2021-10-28
  3 in total