Literature DB >> 33704860

Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Pancreas With Tilted Excitation Plane: A Preliminary Study.

Masahiro Tanabe1, Mayumi Higashi1, Thomas Benkert2, Hiroshi Imai3, Keisuke Miyoshi1, Fumi Kameda1, Shoko Ariyoshi1, Kenichiro Ihara1, Katsuyoshi Ito1.   

Abstract

BACKGROUND: Reduced field-of-view diffusion-weighted imaging (rDWI) with tilted two-dimensional radiofrequency (RF) excitation planes has not yet been applied to the imaging of the pancreas although the utility of this technique which allows the acquisition of high-quality images without aliasing artifacts in the phase-encoding direction has been evaluated for brain and spinal cord imaging.
PURPOSE: To evaluate the visual image quality of the pancreas by tilting the excitation plane (tilted rDWI) in comparison to conventional DWI (cDWI) and rDWI without using the tilted excitation plane. STUDY TYPE: Retrospective. POPULATION: Thirty-two patients evaluated for suspected pancreatobiliary diseases. FIELD STRENGTH/SEQUENCE: Echo-planar imaging DWI (cDWI, rDWI, and tilted rDWI) acquired at 3 T. ASSESSMENT: Images from each DWI sequence were analyzed by five radiologists to compare image quality (conspicuity of pancreatic edges, interslice signal homogeneity, overall image quality, and conspicuity of focal pancreatic lesions) and artifacts (presence of blurring or ghosting artifacts, susceptibility artifacts, and aliasing artifact). STATISTICAL TESTS: Shapiro-Wilk test was performed to assess whether data were normally distributed. Friedman test followed by Bonferroni-adjusted Wilcoxon signed-rank test for post hoc analysis was performed to compare image quality and artifact scores.
RESULTS: The mean scores for conspicuity of pancreatic edges (3.36 vs. 2.37), interslice signal homogeneity (3.14 vs. 2.81), presence of ghosting artifacts (3.32 vs. 2.66), susceptibility artifacts (3.06 vs. 2.30), and aliasing artifacts (3.90 vs. 2.34), and overall image quality (3.49 vs. 2.36) were significantly higher in the tilted rDWI than in the rDWI (P < 0.017 for all parameters). The conspicuity score for focal pancreatic lesions tended to be higher in tilted rDWI than in rDWI (2.44 vs. 2.00, P = 0.07). DATA
CONCLUSION: Tilted rDWI had better image quality and reduced artifacts relative to cDWI and rDWI techniques in the pancreas. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.
© 2021 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  diffusion; excitation plane; pancreas; reduced field-of-view

Year:  2021        PMID: 33704860     DOI: 10.1002/jmri.27590

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  1 in total

1.  Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T.

Authors:  Wenguang Liu; Hui Liu; Simin Xie; Ismail Bilal Masokano; Yu Bai; Xiao Wang; Linhui Zhong; Yi Wu; Jilin Nie; Gaofeng Zhou; Yigang Pei; Wenzheng Li
Journal:  Sci Rep       Date:  2022-07-20       Impact factor: 4.996

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.