Literature DB >> 33687479

Speckle tracking echocardiography in severe patient-prosthesis mismatch.

Altuğ Ösken1,2, Şennur Ünal Dayı3, Kazım Serhan Özcan3, Muhammed Keskin4, Tuğba Kemaloğlu Öz5, Esra Poyraz3, Ufuk Gürkan3, Haldun Akgöz6, Neşe Çam3.   

Abstract

BACKGROUND: Although aortic valve replacement (AVR) when successfully performed boasts low mortality rates in selected patients, prosthesis-patient mismatch (PPM) can be found in the majority of these individuals. Limited research is available supporting the benefit of two-dimensional speckle tracking echocardiography (2D-STE) in patients with severe PPM. This study sought to assess myocardial strain using 2D-STE to determine the relationship between subclinical left ventricular (LV) dysfunction and aortic PPM in patients undergoing AVR with preserved LV ejection fraction.
MATERIAL AND METHODS: We retrospectively examined all consecutive patients with isolated AVR who presented to our center from 2005 to 2018. The data of 1086 patients were analyzed. Severe PPM was defined as an indexed effective orifice area of 0.65 cm2/m2 or less. As a result of the detailed assessment, 54 patients meeting the eligibility criteria were included in the study. Baseline data were collected and compared between the two groups of patients with severe PPM (n = 27) and those with normofunctional aortic prosthesis valve as a control group (n = 27). All patients underwent baseline echocardiography. Global longitudinal strain (GLS) and global circumferential strain (GCS) were evaluated by 2D-STE.
RESULTS: When compared with controls, patients with severe PPM had significantly decreased GLS (18.6 ± 2.9 vs. 21.4 ± 2.1; p < 0.01) and GCS (17.2 ± 3.6 vs. 21.7 ± 2.1; p < 0.01) values.
CONCLUSION: In addition to standard clinical and echocardiographic parameters, GLS and GCS suggest subclinical dysfunction and have incremental value in patients with severe PPM.
© 2021. Springer Medizin Verlag GmbH, ein Teil von Springer Nature.

Entities:  

Keywords:  Aortic valve replacement; Left ventricular function; Myocardial strain imaging; Prosthetic valve; Strain rate

Mesh:

Year:  2021        PMID: 33687479     DOI: 10.1007/s00059-021-05031-4

Source DB:  PubMed          Journal:  Herz        ISSN: 0340-9937            Impact factor:   1.443


  1 in total

1.  Aortic valve replacement with 19-mm bileaflet prostheses in the elderly: left ventricular mass regression and quality of life.

Authors:  Mariano Vicchio; Luca Salvatore De Santo; Alessandro Della Corte; Marisa De Feo; Raffaella Provenzano; Maurizio Miraglia; Michelangelo Scardone; Maurizio Cotrufo
Journal:  J Heart Valve Dis       Date:  2008-03
  1 in total
  1 in total

1.  Role of myocardial strain and rotation for predicting prosthetic aortic valve stenosis.

Authors:  Afag Özyıldız; Bahar Pirat; Ali Gökhan Özyıldız; Haldun Müderrisoğlu
Journal:  Int J Cardiovasc Imaging       Date:  2021-10-09       Impact factor: 2.357

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.