Literature DB >> 33686548

Protein-templated copper nanoclusters for fluorimetric determination of human serum albumin.

Mariagrazia Lettieri1, Pasquale Palladino1, Simona Scarano2, Maria Minunni1.   

Abstract

Copper nanoclusters (CuNCs) are attractive for their unique optical properties, providing sensitive fluorescent detection of several kinds of targets even in complex matrices. Their ability in growing on suitable protein and nucleic acid templates make CuNCs efficient optical reporters to be exploited in bioanalysis. In this work, we report the specific and sensitive determination of human serum albumin (HSA) in human serum (HS) and urine via CuNCs fluorescence. HSA is the most abundant protein in plasma, and plays a key role in the early diagnosis of serious pathological conditions such as albuminuria and albuminemia. Recently, HSA has become clinically central also as a biomarker to assess severity, progression, and prognosis of various cancers. We report the controlled and reproducible growth of CuNCs directly on the target analyte, HSA, which results in a fine dose-dependent fluorescent emission at 405 nm. The protocol is optimized in water, and then applied to serum and urine specimens, without matrix pretreatment. The method linearly responds within the whole concentration of clinical interest, with a sensitivity of 1.8 ± 0.1 × 10-3 g L-1 and 0.62 ± 0.03 × 10-3 g L-1 in serum and urine, respectively, and excellent reproducibility (CVav% ca. 3% for both). The assay is designed to have a single protocol working for both matrices, with recovery of 95% (HS) and 96% (urine). The stability of the fluorescence after CuNCs formation was tested over 3 days, displaying good results (yet higher in urine than in serum).

Entities:  

Keywords:  Copper nanoclusters; Fluorescence; Human serum albumin; Label-free assay

Mesh:

Substances:

Year:  2021        PMID: 33686548      PMCID: PMC7940276          DOI: 10.1007/s00604-021-04764-7

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  30 in total

1.  Red emitting human serum albumin templated copper nanoclusters as effective candidates for highly specific biosensing of bilirubin.

Authors:  Ramar Rajamanikandan; Malaichamy Ilanchelian
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2019-01-12       Impact factor: 7.328

2.  Assessment of immunochemical methods for determining low concentrations of albumin in urine.

Authors:  G F Watts; J E Bennett; D J Rowe; R W Morris; W Gatling; K M Shaw; A Polak
Journal:  Clin Chem       Date:  1986-08       Impact factor: 8.327

Review 3.  Highly fluorescent copper nanoclusters for sensing and bioimaging.

Authors:  Yu An; Ying Ren; Michael Bick; Aleksandra Dudek; Ethan Hong-Wang Waworuntu; Jing Tang; Jun Chen; Baisong Chang
Journal:  Biosens Bioelectron       Date:  2020-02-06       Impact factor: 10.618

4.  Persistent anemia and hypoalbuminemia in rheumatoid arthritis patients with low serum triiodothyronine level.

Authors:  Hideaki Tsuji; Motomu Hashimoto; Takanari Harada; Masao Tanaka; Hiromu Ito; Kosaku Murakami; Koichiro Ohmura; Takao Fujii; Tsuneyo Mimori
Journal:  Mod Rheumatol       Date:  2019-08-08       Impact factor: 3.023

Review 5.  Human serum albumin: from bench to bedside.

Authors:  Gabriella Fanali; Alessandra di Masi; Viviana Trezza; Maria Marino; Mauro Fasano; Paolo Ascenzi
Journal:  Mol Aspects Med       Date:  2011-12-30

6.  Colorimetric determination of total protein content in serum based on the polydopamine/protein adsorption competition on microplates.

Authors:  Pasquale Palladino; Alvaro Brittoli; Emanuela Pascale; Maria Minunni; Simona Scarano
Journal:  Talanta       Date:  2019-01-28       Impact factor: 6.057

Review 7.  Which method for quantifying urinary albumin excretion gives what outcome? A comparison of immunonephelometry with HPLC.

Authors:  Jacoline W Brinkman; Stephan J L Bakker; Ron T Gansevoort; Hans L Hillege; Ido P Kema; Reinold O B Gans; Paul E de Jong; Dick de Zeeuw
Journal:  Kidney Int Suppl       Date:  2004-11       Impact factor: 10.545

8.  Increased degradation of albumin in cancer is not due to conformational or chemical modifications in the albumin molecule.

Authors:  C Andersson; C Lönnroth; L L Moldawer; M Ternell; K Lundholm
Journal:  J Surg Res       Date:  1990-07       Impact factor: 2.192

Review 9.  Pretreatment serum albumin as a predictor of cancer survival: a systematic review of the epidemiological literature.

Authors:  Digant Gupta; Christopher G Lis
Journal:  Nutr J       Date:  2010-12-22       Impact factor: 3.271

Review 10.  Review: Detection and quantification of proteins in human urine.

Authors:  Sultan Aitekenov; Abduzhappar Gaipov; Rostislav Bukasov
Journal:  Talanta       Date:  2020-10-14       Impact factor: 6.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.