Comparison of neurofilament light chain results between two independent facilities.

Tobias Sejbaek1,2, Jason P Mendoza3, Natasha Penner3, Jonna Skov Madsen4,5, Dorte Aalund Olsen5, Zsolt Illes6.   

Abstract

OBJECTIVES: To examine levels of neurofilament light chain (NFL) in identical cerebrospinal fluid (CSF) and blood samples at two different facilities, and how differences affect interpretation of levels within and above the normal range.
METHODS: CSF and plasma from patients with multiple sclerosis (MS) and healthy controls (HCs) were analysed by Simoa (Quanterix) for levels of NFL providing a total of 165 CSF samples (119 from MS) and 225 plasma samples (180 from MS).
RESULTS: CSF and plasma concentrations highly correlated between NFL laboratory facilities (R: 0.92 and 0.84, <0.0001, respectively), and there were no differences between facilities. A bias between the two sites for plasma was -0.95 pg/mL and for CSF -73.53 pg/mL. The cut-offs for CSF were 807.5 and 571.0 pg/mL at site 1 and site 2, respectively; the cut-offs for plasma were 13.0 and 11.8 pg/mL, respectively. Seven out of 180 plasma samples (3.9%) and 3 out of 119 CSF samples (2.5%) from MS patients could be reclassified as normal/abnormal, that is, below/above cut-off, when measured at different facilities.
CONCLUSION: Our study demonstrates that results of NFL in CSF and blood measured with SIMOA are comparable between facilities. Nevertheless, healthcare practitioners should consider reference values at different laboratories, since different sensitivity/specificity can affect interpretation when low values are adjacent to cut-offs. © Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  ALS; CSF; alzheimer's disease; multiple sclerosis; traumatic brain injury

Year:  2020        PMID: 33681796      PMCID: PMC7871722          DOI: 10.1136/bmjno-2020-000063

Source DB:  PubMed          Journal:  BMJ Neurol Open        ISSN: 2632-6140


Introduction

Neurofilament light chain (NFL) is a non-specific marker for neuroaxonal damage that is currently being investigated in several neurological diseases as a possible tool for disease monitoring and management.1–4 NFL levels measured by different technologies have been validated, and the most sensitive commercially available assay is the single molecule array (SIMOA) from Quanterix (Massachusetts, USA).5 6 We examined differences between NFL levels in 165 cerebrospinal fluid (CSF) and 225 blood samples measured with the commercially available assay SIMOA at two different laboratories; we addressed if potential differences affect the interpretation of presumed clinical activity in multiple sclerosis (MS) based on NFL levels.

Methods

Study design

The Tecfidera in Relapsing-Remitting Multiple Sclerosis: Endothelial Dysfunction (TREMEND) study is a prospective open-label phase IV trial, which enrolled newly diagnosed patients with MS with relapsing-remitting multiple sclerosis from March 2014 until August 2016 (EudraCT 2014-000254-11) and treated with dimethyl fumarate (DMF) for 24 months.7

Sample collection NFL analysis

Plasma were collected at baseline, 3, 6, 12 and 24 months of treatment with DMF from patients enrolled in the TREMEND trial (n=52) and from healthy controls (HCs) (n=23). CSF was collected, however optional as part of the TREMEND trial at baseline and after 12 months of DMF treatment. Samples from baseline and 12 months were analysed for NFL at two different facilities. Patients were 34.1 (±8.7) years old and 86.6% women; HCs were on average 38.2 (±11.2) years old and 89.2% women. Samples were collected following international guidelines for biobanking; venous blood was drawn in evacuated K2-EDTA containing blood collection tubes and both blood and CSF were centrifuged within 30–60 min after collection at 2000 G for 10 min at 20°C, plasma and CSF were aliquoted in 500 µL Sarstedt polypropylene tubes and stored at −80°C until batch analysis.8 Blood and CSF samples were taken from the cubital vein and by spinal tap.

NFL analysis

NFL was analysed in the same batch at each facility.9 Samples were thawed once before aliquoting and shipping, and once again before analysing at the two laboratory facilities. A commercially available NFL kit (Quanterix, Lexington, Massachusetts, USA) for the Single Molecule Array (Simoa) HD-1 Analyzer (Quanterix) was used to quantify NFL light chain in serum and CSF according to the manufacturer’s procedure. The results from site 1 (Quanterix) have previously been published.7 Samples were reanalysed at the Department of Biochemistry and Immunology, Lillebaelt Hospital, Vejle, a routine laboratory being accredited by Danish Accreditation Fund (DANAK) according to the ISO 15189 standard. Quality control was performed using two controls prepared from commercially available control material provided by the manufacturer. In-house serum and CSF pools were used as internal controls (plasma pool 25 pg/mL and CSF pool 1350 pg/mL) and included in each assay for evaluating assay performance. Samples analysed at site 1 (Quanterix) were analysed in single measures while at site 2 in duplicates and the mean was calculated. The intermediate precision was <9.3% at site 1 and <12% at site 2. Lower limit of detection was 0.038 pg/mL and lower limit of quantification was 0.174 pg/mL at both laboratories. The intermediate precision expresses within-laboratory variations: different days, different analysts, different reagent lots, and so on.

Standard protocol approvals, registrations, patient consents and monitoring

All patients and HCs gave written and oral consent. The trial was monitored according to the national laws by the unit for good clinical practice at Odense University Hospital, Odense, Denmark, and South West Jutland University Hospital, Esbjerg, Denmark.

Statistical analyses

We described baseline characteristics with means and SD for continuous variables. Linear fit regression was performed using Spearman linear fit regression to calculate coefficients and linearity between NFL in CSF and plasma. Data were checked for normality using D’Agostino and Pearson normality test. Bland-Altman analysis was performed to compare differences between the two laboratory sites and evaluate bias. Receiver operating characteristic (ROC) analysis was performed to identify differences in cut-offs, specificity and sensitivity between the two NFL laboratory facilities. We performed non-parametric analysis with Kruskal-Wallis test and Dunn’s multiple comparisons. Statistical analysis and data management were performed using GraphPad Prism V.8.

Results

NFL concentrations were analysed and compared in 165 CSF and 225 plasma samples measured by SIMOA method at two different laboratory facilities (sites), respectively (table 1; figure 1A, B). Baseline NFL levels in patients with MS were 2368 (±1947) pg/mL and 16.4 (±14.4) pg/mL in CSF and plasma, respectively, compared with lower levels in HCs (416 (±191) and 7.3 (±3.0) in CSF and plasma, respectively) (p<0.0001 in both CSF and plasma). Linear regression was used for correlation, and agreement between the two assays at the two sites was examined by Bland-Altman analysis (figure 1C–F). We found that both CSF and plasma concentrations were highly correlated between NFL laboratory facilities (R: 0.92 and 0.84, p<0.0001, respectively), and we did not find significant differences between the two sites (figure 1C–D). A systematic bias between the two sites calculated by the Bland-Altman analysis was −0.95 pg/mL for plasma and −73.53 pg/mL for CSF. Site 2 measured lower concentration of NFL in both plasma and CSF compared with site 1. When NFL concentration in identical CSF and plasma samples measured at the two sites were compared, only minor differences were found apart from a few outliers (1%–2% of samples) (figure 1G, H).
Table 1

Comparison of NFL levels in plasma and CSF measured at two different NFL laboratory facilities

Site 1Site 2P valueSite 1Site 2P value
CSF BLn=30CSF BLn=25CSF 12n=35CSF 12n=29
Mean23682879>0.99644604>0.99
SD19471989576472
SE3563989788
P BLn=47P BLn=44P 12n=47P 12n=42
Mean1620>0.997.48.3>0.99
SD14163.14.5
SE2.12.30.50.7
P HCn=22P HCn=23CSF HCn=23CSF HCn=23
Mean7.35.1>0.99417283>0.99
SD3.02.1191117
SEM0.60.44024

Dunn’s multiple comparisons test comparing the levels of NFL (pg/mL) in CSF (total number 165) and plasma (total number 225), between two sites. Samples were from patients with multiple sclerosis, before and after 12 months of treatment with dimethyl fumarate and a HC group. Site 1 and site 2 are two independent NFL laboratories. P12 and CSF12=samples at 12 months.

BL, baseline samples; CSF, cerebrospinal fluid; HC, healthy control; n, number; NFL, neurofilament light chain; P, plasma.

Figure 1

Comparison of neurofilament light chain (NFL) levels in cerebrospinal fluid (CSF) and plasma measured at two different facilities. (A and B) Scatter dot plot with levels of NFL at baseline (BL), after 12 months (12) treatment with dimethyl fumarate (DMF), and in healthy controls (HC) at site 1 and site 2. Whiskers indicate SD and mean. (C and D) The figure depicts linear regression analysis of paired samples at site 1 and site 2. (E and F) Bland-Altman plot with differences between sites (site 1 minus site 2) versus average are shown. (F and G) Paired NFL measured in the same samples at site 1 and site 2 are shown. In three samples, CSF NFL were below cut-off (807.5 pg/mL) at site 1 and above cut-off (571.0 pg/mL) at site 2. NFL levels in six plasma samples were below cut-off (13.0 pg/mL) at site 1 and at above cut-off (11.8 pg/mL) at site 2. NFL level in a single plasma sample was above cut-off at site 1 and below cut-off at site 2.

Comparison of NFL levels in plasma and CSF measured at two different NFL laboratory facilities Dunn’s multiple comparisons test comparing the levels of NFL (pg/mL) in CSF (total number 165) and plasma (total number 225), between two sites. Samples were from patients with multiple sclerosis, before and after 12 months of treatment with dimethyl fumarate and a HC group. Site 1 and site 2 are two independent NFL laboratories. P12 and CSF12=samples at 12 months. BL, baseline samples; CSF, cerebrospinal fluid; HC, healthy control; n, number; NFL, neurofilament light chain; P, plasma. Comparison of neurofilament light chain (NFL) levels in cerebrospinal fluid (CSF) and plasma measured at two different facilities. (A and B) Scatter dot plot with levels of NFL at baseline (BL), after 12 months (12) treatment with dimethyl fumarate (DMF), and in healthy controls (HC) at site 1 and site 2. Whiskers indicate SD and mean. (C and D) The figure depicts linear regression analysis of paired samples at site 1 and site 2. (E and F) Bland-Altman plot with differences between sites (site 1 minus site 2) versus average are shown. (F and G) Paired NFL measured in the same samples at site 1 and site 2 are shown. In three samples, CSF NFL were below cut-off (807.5 pg/mL) at site 1 and above cut-off (571.0 pg/mL) at site 2. NFL levels in six plasma samples were below cut-off (13.0 pg/mL) at site 1 and at above cut-off (11.8 pg/mL) at site 2. NFL level in a single plasma sample was above cut-off at site 1 and below cut-off at site 2. Finally, we examined if interpretation of results may change, when the same samples are examined for NFL at the different facilities with their own calculated cut-offs, specificity and sensitivity based on the results (figure 1G, H). We therefore calculated cut-off values at both laboratories by ROC analysis for both plasma and CSF.7 The cut-offs for CSF were 807.5 and 571.0 pg/mL at site 1 and site 2, respectively; the cut-offs for plasma were 13.0 and 11.8 pg/mL, respectively. For CSF, we found a sensitivity of 80.0% (95% CI: 62.7% to 90.5%) and a specificity of 100.0% (95% CI: 85.7% to 100.0%) at site 1, whereas site 2 demonstrated a higher sensitivity of 92.0% (95% CI: 75.0% to 98.6%) with the same specificity of 100.0% (95% CI: 85.7% to 100.0%). For plasma, we found a sensitivity of 46.8% (95% CI: 33.3% to 60.8%) and a specificity of 100.0% (95% CI: 85.1% to 100.0%) at site 1, whereas site 2 demonstrated again higher sensitivity of 63.6% (95% CI: 48.9% to 76.2%) with the same specificity of 100.0% (95% CI: 85.7% to 100.0%). Area under ROC curve for CSF was 0.93 (SE: 0.035, p<0.0001) and 0.98 (SE: 0.016, p<0.0001) for sites 1 and 2, respectively. Area under ROC curve for plasma was 0.76 (SE: 0.057, p<0.001) and 0.94 (SE: 0.027, p<0.0001) for sites 1 and 2, respectively. The concentrations of NFL in individual samples were then examined by using these established cut-off values at both sites. We found that 7 out 180 plasma samples (3.9%) could be reclassified as normal/abnormal, that is, below/above cut-off, when measured at different sites (figure 1H). Similarly, 3 out of 119 CSF samples (2.8%) could be reclassified as normal/abnormal (figure 1G).

Discussion

We determined NFL levels in identical CSF and plasma samples at two independent laboratory facilities using the commercially available highly sensitive assay from Quanterix. No differences between these laboratory facilities could be found on the group level (table 1). Linear fit regression demonstrated good correlation between facilities, however with better correlation in CSF than in plasma. We found a small bias (for plasma −0.95 pg/mL and for CSF −73.53 pg/mL) with one laboratory facility determining lower concentrations in both plasma and CSF than the other site. This bias was also reflected in the difference between the identified cut-offs. Bias between laboratory facilities is well documented for NFL and other biomarkers even with higher variation than in our study.10 Site 2 had a slightly higher sensitivity in both plasma and CSF compared with site 1. Such differences in cut-offs and sensitivity/specificity resulted in a reclassification of approximately 3%–4% of patients’ samples below and above cut-off in plasma and CSF, while none of the HC samples were reclassified. We have recently shown that 22% of patients with normal NFL levels in the plasma had elevated levels in the paired CSF sample.7 Our present data add another factor to the complexity of interpreting NFL levels in patients with MS. These data altogether indicate that in a small percentage of patients with MS, variability in laboratory methods and lower sensitivity in the plasma may result in interpretation of ‘no clinical activity’ based on plasma NFL, while CSF or a different laboratory may conclude the opposite. Therefore, standardisation of methodology, individual cut-offs or percentiles at different laboratory facilities, and regular sampling of blood for NFL may be required.11 12 This is, to our knowledge, the first study comparing NFL levels in identical paired samples from CSF and plasma at two NFL laboratory facilities. Our results demonstrate that healthcare practitioners should take into account the local reference values, when comparing consecutive levels of NFL in their clinical practice. However, differences tend to be minor between facilities, and only low values around cut-offs should be interpreted with caution. This study is not without limitations. Sera was not analyzed, although it might provide better option than plasma: NFL concentration is 23% higher in sera, and the clinical implication might be different in sera compared to plasma.7 In conclusion, our study demonstrates that results of NFL in CSF and blood measured with SIMOA from Quanterix are comparable between two different NFL laboratory facilities. Nevertheless, healthcare practitioners should consider reference values from different laboratory facilities especially, when consecutive samples analysed by different facilities are compared. Different sensitivity/specificity can affect data interpretation in 4% of cases, when results are around cut-offs, however on an individual patient level, effort should be made to use the same NFL laboratory facility. These data warrant additional larger studies comparing different variables reflective of clinical practice.
  12 in total

1.  Neurofilament levels as biomarkers in asymptomatic and symptomatic familial amyotrophic lateral sclerosis.

Authors:  Patrick Weydt; Patrick Oeckl; André Huss; Kathrin Müller; Alexander E Volk; Jens Kuhle; Antje Knehr; Peter M Andersen; Johannes Prudlo; Petra Steinacker; Jochen H Weishaupt; Albert C Ludolph; Markus Otto
Journal:  Ann Neurol       Date:  2015-12-17       Impact factor: 10.422

Review 2.  Neurofilament light chain as a biomarker in neurological disorders.

Authors:  Lorenzo Gaetani; Kaj Blennow; Paolo Calabresi; Massimiliano Di Filippo; Lucilla Parnetti; Henrik Zetterberg
Journal:  J Neurol Neurosurg Psychiatry       Date:  2019-04-09       Impact factor: 10.154

3.  Neurofilament light for measuring the treatment efficacy in clinical practice: are we there yet?

Authors:  Lenka Novakova
Journal:  J Neurol Neurosurg Psychiatry       Date:  2019-10-13       Impact factor: 10.154

Review 4.  Neurofilaments as biomarkers in neurological disorders.

Authors:  Michael Khalil; Charlotte E Teunissen; Markus Otto; Fredrik Piehl; Maria Pia Sormani; Thomas Gattringer; Christian Barro; Ludwig Kappos; Manuel Comabella; Franz Fazekas; Axel Petzold; Kaj Blennow; Henrik Zetterberg; Jens Kuhle
Journal:  Nat Rev Neurol       Date:  2018-10       Impact factor: 42.937

5.  Neurofilament protein in cerebrospinal fluid: a potential marker of activity in multiple sclerosis.

Authors:  J N Lycke; J E Karlsson; O Andersen; L E Rosengren
Journal:  J Neurol Neurosurg Psychiatry       Date:  1998-03       Impact factor: 10.154

6.  A consensus protocol for the standardization of cerebrospinal fluid collection and biobanking.

Authors:  C E Teunissen; A Petzold; J L Bennett; F S Berven; L Brundin; M Comabella; D Franciotta; J L Frederiksen; J O Fleming; R Furlan; R Q Hintzen; S G Hughes; M H Johnson; E Krasulova; J Kuhle; M C Magnone; C Rajda; K Rejdak; H K Schmidt; V van Pesch; E Waubant; C Wolf; G Giovannoni; B Hemmer; H Tumani; F Deisenhammer
Journal:  Neurology       Date:  2009-12-01       Impact factor: 9.910

7.  Comparison of three analytical platforms for quantification of the neurofilament light chain in blood samples: ELISA, electrochemiluminescence immunoassay and Simoa.

Authors:  Jens Kuhle; Christian Barro; Ulf Andreasson; Tobias Derfuss; Raija Lindberg; Åsa Sandelius; Victor Liman; Niklas Norgren; Kaj Blennow; Henrik Zetterberg
Journal:  Clin Chem Lab Med       Date:  2016-10-01       Impact factor: 3.694

8.  Plasma Concentration of the Neurofilament Light Protein (NFL) is a Biomarker of CNS Injury in HIV Infection: A Cross-Sectional Study.

Authors:  Magnus Gisslén; Richard W Price; Ulf Andreasson; Niklas Norgren; Staffan Nilsson; Lars Hagberg; Dietmar Fuchs; Serena Spudich; Kaj Blennow; Henrik Zetterberg
Journal:  EBioMedicine       Date:  2015-11-22       Impact factor: 8.143

9.  Association of Plasma Neurofilament Light With Neurodegeneration in Patients With Alzheimer Disease.

Authors:  Niklas Mattsson; Ulf Andreasson; Henrik Zetterberg; Kaj Blennow
Journal:  JAMA Neurol       Date:  2017-05-01       Impact factor: 18.302

10.  Multicentre comparison of a diagnostic assay: aquaporin-4 antibodies in neuromyelitis optica.

Authors:  Patrick Waters; Markus Reindl; Albert Saiz; Kathrin Schanda; Friederike Tuller; Vlastimil Kral; Petra Nytrova; Ondrej Sobek; Helle Hvilsted Nielsen; Torben Barington; Søren T Lillevang; Zsolt Illes; Kristin Rentzsch; Achim Berthele; Tímea Berki; Letizia Granieri; Antonio Bertolotto; Bruno Giometto; Luigi Zuliani; Dörte Hamann; E Daniëlle van Pelt; Rogier Hintzen; Romana Höftberger; Carme Costa; Manuel Comabella; Xavier Montalban; Mar Tintoré; Aksel Siva; Ayse Altintas; Günnur Deniz; Mark Woodhall; Jacqueline Palace; Friedemann Paul; Hans-Peter Hartung; Orhan Aktas; Sven Jarius; Brigitte Wildemann; Christian Vedeler; Anne Ruiz; M Isabel Leite; Peter Trillenberg; Monika Probst; Sandra Saschenbrecker; Angela Vincent; Romain Marignier
Journal:  J Neurol Neurosurg Psychiatry       Date:  2016-04-25       Impact factor: 10.154

View more
  2 in total

1.  CSF-Neurofilament Light Chain Levels in NMDAR and LGI1 Encephalitis: A National Cohort Study.

Authors:  Mette Scheller Nissen; Matias Ryding; Anna Christine Nilsson; Jonna Skov Madsen; Dorte Aalund Olsen; Ulrich Halekoh; Magnus Lydolph; Zsolt Illes; Morten Blaabjerg
Journal:  Front Immunol       Date:  2021-12-16       Impact factor: 7.561

Review 2.  Emerging Biomarkers of Multiple Sclerosis in the Blood and the CSF: A Focus on Neurofilaments and Therapeutic Considerations.

Authors:  Tamás Biernacki; Zsófia Kokas; Dániel Sandi; Judit Füvesi; Zsanett Fricska-Nagy; Péter Faragó; Tamás Zsigmond Kincses; Péter Klivényi; Krisztina Bencsik; László Vécsei
Journal:  Int J Mol Sci       Date:  2022-03-21       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.