Literature DB >> 33680560

Real-time tool to layer distance estimation for robotic subretinal injection using intraoperative 4D OCT.

Michael Sommersperger1,2, Jakob Weiss2, M Ali Nasseri2,3, Peter Gehlbach1, Iulian Iordachita1, Nassir Navab1,2.   

Abstract

The emergence of robotics could enable ophthalmic microsurgical procedures that were previously not feasible due to the precision limits of manual delivery, for example, targeted subretinal injection. Determining the distance between the needle tip, the internal limiting membrane (ILM), and the retinal pigment epithelium (RPE) both precisely and reproducibly is required for safe and successful robotic retinal interventions. Recent advances in intraoperative optical coherence tomography (iOCT) have opened the path for 4D image-guided surgery by providing near video-rate imaging with micron-level resolution to visualize retinal structures, surgical instruments, and tool-tissue interactions. In this work, we present a novel pipeline to precisely estimate the distance between the injection needle and the surface boundaries of two retinal layers, the ILM and the RPE, from iOCT volumes. To achieve high computational efficiency, we reduce the analysis to the relevant area around the needle tip. We employ a convolutional neural network (CNN) to segment the tool surface, as well as the retinal layer boundaries from selected iOCT B-scans within this tip area. This results in the generation and processing of 3D surface point clouds for the tool, ILM and RPE from the B-scan segmentation maps, which in turn allows the estimation of the minimum distance between the resulting tool and layer point clouds. The proposed method is evaluated on iOCT volumes from ex-vivo porcine eyes and achieves an average error of 9.24 µm and 8.61 µm measuring the distance from the needle tip to the ILM and the RPE, respectively. The results demonstrate that this approach is robust to the high levels of noise present in iOCT B-scans and is suitable for the interventional use case by providing distance feedback at an average update rate of 15.66 Hz.
© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Entities:  

Year:  2021        PMID: 33680560      PMCID: PMC7901333          DOI: 10.1364/BOE.415477

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  4 in total

1.  Development and ex-vivo validation of 36G polyimide cannulas integrating a guiding miniaturized OCT probe for robotic assisted subretinal injections.

Authors:  Alexandre Abid; Renaud Duval; Christos Boutopoulos
Journal:  Biomed Opt Express       Date:  2022-01-20       Impact factor: 3.732

2.  Feasibility of the soft attention-based models for automatic segmentation of OCT kidney images.

Authors:  Mousa Moradi; Xian Du; Tianxiao Huan; Yu Chen
Journal:  Biomed Opt Express       Date:  2022-04-11       Impact factor: 3.562

Review 3.  Intravitreal Injectable Hydrogels for Sustained Drug Delivery in Glaucoma Treatment and Therapy.

Authors:  Kassahun Alula Akulo; Terin Adali; Mthabisi Talent George Moyo; Tulin Bodamyali
Journal:  Polymers (Basel)       Date:  2022-06-10       Impact factor: 4.967

4.  Surgical scene generation and adversarial networks for physics-based iOCT synthesis.

Authors:  Michael Sommersperger; Alejandro Martin-Gomez; Kristina Mach; Peter Louis Gehlbach; M Ali Nasseri; Iulian Iordachita; Nassir Navab
Journal:  Biomed Opt Express       Date:  2022-03-23       Impact factor: 3.562

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.