Literature DB >> 33680538

Effect of A-scan rate and interscan interval on optical coherence angiography.

Ting-Hao Chen1, Yi-Chun Wu1, Ting-Yen Tsai1, Chuan-Bor Chueh1, Bo-Huei Huang2, Yin-Peng Huang3, Meng-Tsan Tsai2,4, Yoshiaki Yasuno5, Hsiang-Chieh Lee1,6,7.   

Abstract

Optical coherence tomography angiography (OCTA) can provide rapid, volumetric, and noninvasive imaging of tissue microvasculature without the requirement of exogenous contrast agents. To investigate how A-scan rate and interscan time affected the contrast and dynamic range of OCTA, we developed a 1.06-µm swept-source OCT system enabling 100-kHz or 200-kHz OCT using two light sources. After system settings were carefully adjusted, almost the same detection sensitivity was achieved between the 100-kHz and 200-kHz modalities. OCTA of ear skin was performed on five mice. We used the variable interscan time analysis algorithm (VISTA) and the designated scanning protocol with OCTA images reconstructed through the correlation mapping method. With a relatively long interscan time (e.g., 12.5 ms vs. 6.25 ms for 200-kHz OCT), OCTA can identify more intricate microvascular networks. OCTA image sets with the same interscan time (e.g., 12.5 ms) were compared. OCTA images acquired with a 100-kHz A-scan rate showed finer microvasculature than did other imaging modalities. We performed quantitative analysis on the contrast from OCTA images reconstructed with different A-scan rates and interscan time intervals in terms of vessel area, total vessel length, and junction density.
© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Entities:  

Year:  2021        PMID: 33680538      PMCID: PMC7901325          DOI: 10.1364/BOE.409636

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  3 in total

1.  Numerical calibration method for a multiple spectrometer-based OCT system.

Authors:  Yusi Miao; Jun Song; Destiny Hsu; Ringo Ng; Yifan Jian; Marinko V Sarunic; Myeong Jin Ju
Journal:  Biomed Opt Express       Date:  2022-02-24       Impact factor: 3.732

Review 2.  Enhanced medical diagnosis for dOCTors: a perspective of optical coherence tomography.

Authors:  Rainer Leitgeb; Fabian Placzek; Elisabet Rank; Lisa Krainz; Richard Haindl; Qian Li; Mengyang Liu; Marco Andreana; Angelika Unterhuber; Tilman Schmoll; Wolfgang Drexler
Journal:  J Biomed Opt       Date:  2021-10       Impact factor: 3.758

Review 3.  Towards standardizing retinal optical coherence tomography angiography: a review.

Authors:  Danuta M Sampson; Adam M Dubis; Fred K Chen; Robert J Zawadzki; David D Sampson
Journal:  Light Sci Appl       Date:  2022-03-18       Impact factor: 17.782

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.