Literature DB >> 33676532

Appropriate margin for planning target volume for breast radiotherapy during deep inspiration breath-hold by variance component analysis.

Yuka Ono1, Michio Yoshimura2, Tomohiro Ono1, Takahiro Fujimoto3, Yuki Miyabe1, Yukinori Matsuo1, Takashi Mizowaki1.   

Abstract

BACKGROUND: This study aimed to quantify errors by using a cine electronic portal imaging device (cine EPID) during deep inspiration breath-hold (DIBH) for left-sided breast cancer and to estimate the planning target volume (PTV) by variance component analysis.
METHODS: This study included 25 consecutive left-sided breast cancer patients treated with whole-breast irradiation (WBI) using DIBH. Breath-holding was performed while monitoring abdominal anterior-posterior (AP) motion using the Real-time Position Management (RPM) system. Cine EPID was used to evaluate the chest wall displacements in patients. Cine EPID images of the patients (309,609 frames) were analyzed to detect the edges of the chest wall using a Canny filter. The errors that occurred during DIBH included differences between the chest wall position detected by digitally reconstructed radiographs and that of all cine EPID images. The inter-patient, inter-fraction, and intra-fractional standard deviations (SDs) in the DIBH were calculated, and the PTV margin was estimated by variance component analysis.
RESULTS: The median patient age was 55 (35-79) years, and the mean irradiation time was 20.4 ± 1.7 s. The abdominal AP motion was 1.36 ± 0.94 (0.14-5.28) mm. The overall mean of the errors was 0.30 mm (95% confidence interval: - 0.05-0.65). The inter-patient, inter-fraction, and intra-fractional SDs in the DIBH were 0.82 mm, 1.19 mm, and 1.63 mm, respectively, and the PTV margin was calculated as 3.59 mm.
CONCLUSIONS: Errors during DIBH for breast radiotherapy were monitored using EPID images and appropriate PTV margins were estimated by variance component analysis.

Entities:  

Keywords:  Breast cancer; Cine electronic portal imaging device; Deep inspiration breath-hold; Inter-fraction; Inter-patient; Intra-fraction; Planning target volume margin

Year:  2021        PMID: 33676532     DOI: 10.1186/s13014-021-01777-7

Source DB:  PubMed          Journal:  Radiat Oncol        ISSN: 1748-717X            Impact factor:   3.481


  1 in total

1.  Clinical experience using a video-guided spirometry system for deep inhalation breath-hold radiotherapy of left-sided breast cancer.

Authors:  Wensha Yang; Elizabeth M McKenzie; Michele Burnison; Stephen Shiao; Amin Mirhadi; Behrooz Hakimian; Robert Reznik; Richard Tuli; Howard Sandler; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

  1 in total
  3 in total

1.  Accuracy of patient setup positioning using surface-guided radiotherapy with deformable registration in cases of surface deformation.

Authors:  Boriphat Kadman; Akihiro Takemura; Tatsuya Ito; Naoki Okada; Hironori Kojima; Shinichi Ueda
Journal:  J Appl Clin Med Phys       Date:  2022-01-25       Impact factor: 2.243

2.  Evaluation of internal margins for prostate for step and shoot intensity-modulated radiation therapy and volumetric modulated arc therapy using different margin formulas.

Authors:  Daiki Higuchi; Tomohiro Ono; Ryo Kakino; Rihito Aizawa; Naoki Nakayasu; Hitoshi Ito; Takashi Sakamoto
Journal:  J Appl Clin Med Phys       Date:  2022-06-19       Impact factor: 2.243

3.  Does the protocol-required uniform margin around the CTV adequately account for setup inaccuracies in whole breast irradiation?

Authors:  Jurui Luo; Zhihai Yin; Zhen Zhang; Xiaomao Guo; Xiaoli Yu; Juanqi Wang
Journal:  Radiat Oncol       Date:  2021-08-03       Impact factor: 3.481

  3 in total