Literature DB >> 33676163

An ultrasensitive heart-failure BNP biosensor using B/N co-doped graphene oxide gel FET.

I Novodchuk1, M Kayaharman2, I R Ausri3, R Karimi4, X S Tang3, I A Goldthorpe2, E Abdel-Rahman5, J Sanderson4, M Bajcsy6, M Yavuz7.   

Abstract

Heart failure (HF) is the number one cause of death in the world. B-type natriuretic peptide (BNP) is a recognized biomarker for HF and can be used for early detection. Field effect transistor (FET) biosensors have the ability to sense BNP in much shorter times than conventional clinical studies. The lowest limit of detection (LOD) of state-of-the-art HF FET biosensors is 100 fM and detection ranges are short, being less than 4 orders of magnitude. In this work, a B/N co-doped graphene oxide (GO) gel (BN-GO) was used as the channel material in an FET biosensor targeting BNP. The sensor was able to sense BNP in as little as 2 min, with an LOD as low as 10 aM and a wide linear detection range of 10 aM-1 μM, stretching over 11 orders of magnitude. The biosensor showed great selectivity and minimal response towards K+ and OH- ions and the human epidermal growth factor receptor (HER2) protein. This biosensor serves as a proof-of-concept of the ability of BN-GO gel FETs to be used for ultrasensitive biosensors.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; FET; Graphene-based; Heart failure

Mesh:

Substances:

Year:  2021        PMID: 33676163     DOI: 10.1016/j.bios.2021.113114

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

Review 1.  Multifunctional carbon nanomaterials for diagnostic applications in infectious diseases and tumors.

Authors:  Yang He; Chenyan Hu; Zhijia Li; Chuan Wu; Yuanyuan Zeng; Cheng Peng
Journal:  Mater Today Bio       Date:  2022-03-05

Review 2.  Graphene-Based Biosensors for Molecular Chronic Inflammatory Disease Biomarker Detection.

Authors:  Isidro Badillo-Ramírez; Yojana J P Carreón; Claudia Rodríguez-Almazán; Claudia M Medina-Durán; Selene R Islas; José M Saniger
Journal:  Biosensors (Basel)       Date:  2022-04-14

3.  Electronic field effect detection of SARS-CoV-2 N-protein before the onset of symptoms.

Authors:  I Novodchuk; M Kayaharman; I Prassas; A Soosaipillai; R Karimi; I A Goldthorpe; E Abdel-Rahman; J Sanderson; E P Diamandis; M Bajcsy; M Yavuz
Journal:  Biosens Bioelectron       Date:  2022-04-29       Impact factor: 12.545

4.  Efficacy of graphene oxide-loaded cationic antimicrobial peptide AWRK6 on the neutralization of endotoxin activity and in the treatment of sepsis.

Authors:  Bo Song; Hongli Zhao; Haiyan Yang; Shengji Wang
Journal:  Aging (Albany NY)       Date:  2021-08-13       Impact factor: 5.682

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.