Literature DB >> 33672213

Radioligand Assay-Based Detection of Antibodies against SARS-CoV-2 in Hospital Workers Treating Patients with Severe COVID-19 in Japan.

Hidenori Matsunaga1, Akiko Makino2, Yasuhiro Kato3, Teruaki Murakami3, Yuta Yamaguchi3, Atsushi Kumanogoh3, Yuichiro Oba4, Satoshi Fujimi5, Tomoyuki Honda6, Keizo Tomonaga2.   

Abstract

This study aimed to clarify whether infection by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is prevalent among the staff of a hospital providing treatment to patients with severe coronavirus disease 2019 (COVID-19) using radioligand assay (RLA). One thousand samples from the staff of a general hospital providing treatment to patients with severe COVID-19 were assayed for SARS-CoV-2 nucleocapsid protein (N) IgG using RLA. Nine patients with COVID-19 who had been treated in inpatient settings and had already recovered were used as control subjects, and 186 blood donor samples obtained more than 10 years ago were used as negative controls. Four of the 1000 samples showed apparently positive results, and approximately 10 or more samples showed slightly high counts. Interestingly, a few among the blood donor samples also showed slightly high values. To validate the results, antibody examinations using ELISA and neutralizing antibody tests were performed on 21 samples, and chemiluminescence immunoassay (CLIA) was performed on 201 samples, both resulting in a very high correlation. One blood donor sample showed slightly positive results in both RLA and CLIA, suggesting a cross-reaction. This study showed that five months after the pandemic began in Japan, the staff of a general hospital with a tertiary emergency medical facility had an extremely low seroprevalence of the antibodies against SARS-CoV-2. Further investigation will be needed to determine whether the slightly high results were due to cross-reactions or a low titer of anti-SARS-CoV-2 antibodies. The quantitative RLA was considered sensitive enough to detect low titers of antibodies.

Entities:  

Keywords:  SARS-CoV-2; antibody; cross reaction; hospital staff; low-titer; radioligand assay

Year:  2021        PMID: 33672213     DOI: 10.3390/v13020347

Source DB:  PubMed          Journal:  Viruses        ISSN: 1999-4915            Impact factor:   5.048


  1 in total

1.  Waning of Anti-SARS-CoV-2 Spike Antibody Levels 100 to 200 Days after the Second Dose of the BNT162b2 Vaccine.

Authors:  Hidenori Matsunaga; Hidefumi Takeuchi; Yuichiro Oba; Satoshi Fujimi; Tomoyuki Honda; Keizo Tomonaga
Journal:  Vaccines (Basel)       Date:  2022-01-24
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.