Swine Small Intestine Sealing Performed by Different Vessel Sealing Devices: Ex-Vivo Test.

Luca Lacitignola1, Annarita Imperante2, Rodrigo Trisciuzzi2, Nicola Zizzo3, Alberto Maria Crovace4, Francesco Staffieri1.   

Abstract

This study aimed to evaluate the sealing quality of swine small intestine using different laparoscopic radiofrequency vessel sealing devices (two 5 mm: RFVS-1 and -2; one 10 mm: RFVS-3) and a harmonic scalpel (HS) compared to golden standard closure technique. The study was divided into two arms. In study arm 1: n = 50 swine intestinal loops (10 per group) were transected with each instrument and the loops in which the devices provided complete sealing, at the gross inspection, were tested for maximum burst pressure (BP) and histological evaluation and compared to an automatic linear stapler. After the BP tests, the devices that achieved significantly lower BP values were excluded from the second arm. The RFVS-1 and -3 provided statistically significant results and were used in study arm 2, to obtain full-thickness biopsies along the antimesenteric border of the loop and were compared with hand-sewn intestinal closure (n = 30; 10 per group). The biopsies were histologically evaluated for thermal injury and diagnostic features, and intestinal loops tested for BP. RFVS-3 achieved comparable results (69.78 ± 4.23 mmHg, interquartile range (IQR) 5.8) to stapler closing technique (71.09 ± 4.22 mmHg, IQR 4.38; p > 0.05), while the RFVS-1 resulted in significantly (p < 0.05) lower BP (45.28 ± 15.23 mmHg, IQR 24.95) but over the physiological range, conversely to RFVS-2 (20.16 ± 7.19 mmHg, IQR 12.02) and HS (not measurable). RFVS-3 resulted not significantly different (p > 0.05) (45.09 ± 8.75 mmHg, IQR 10.48) than Suture (35.71 ± 17.51 mmHg, IQR 23.77); RFVS-1 resulted significantly lower values (23.96 ± 10.63 mmHg, IQR 9.62; p < 0.05). All biopsies were judged diagnostic. Data confirmed that RFVS-1 and -3 devices provided suitable intestinal sealing, with BP pressures over the physiological range. Conversely, the HS and RFVS-2 should not be considered for intestinal sealing. RFVS devices could be employed to obtain small intestine stump closure or full-thickness biopsies. However, further studies should be performed in live animals to assess the role of the healing process.

Entities:  

Keywords:  burst pressure; full-thickness biopsy; harmonic scalpel; leak pressure; radiofrequency vessel sealing device; small intestine; swine; vessel sealing device

Year:  2021        PMID: 33671834     DOI: 10.3390/vetsci8020034

Source DB:  PubMed          Journal:  Vet Sci        ISSN: 2306-7381


  2 in total

1.  Dynamic Impedance Analysis of Intestinal Anastomosis during High-Frequency Electric Field Welding Process.

Authors:  Li Yin; Caihui Zhu; Jianzhi Xu; Hui Zhao; Jian Qiu; Hao Wang; Kefu Liu
Journal:  Sensors (Basel)       Date:  2022-05-28       Impact factor: 3.847

2.  Ex-Vivo Evaluation of "First Tip Closing" Radiofrequency Vessel Sealing Devices for Swine Small Intestinal Transection.

Authors:  Luca Lacitignola; Alberto Crovace; Giuseppe Passantino; Francesco Staffieri
Journal:  Vet Sci       Date:  2022-08-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.