Evaluation of MicroScan Bacterial Identification Panels for Low-Resource Settings.

Sien Ombelet1,2, Alessandra Natale3, Jean-Baptiste Ronat3,4,5, Olivier Vandenberg6,7,8, Liselotte Hardy1, Jan Jacobs1,2.   

Abstract

Bacterial identification is challenging in low-resource settings (LRS). We evaluated the MicroScan identification panels (Beckman Coulter, Brea, CA, USA) as part of Médecins Sans Frontières' Mini-lab Project. The MicroScan Dried Overnight Positive ID Type 3 (PID3) panels for Gram-positive organisms and Dried Overnight Negative ID Type 2 (NID2) panels for Gram-negative organisms were assessed with 367 clinical isolates from LRS. Robustness was studied by inoculating Gram-negative species on the Gram-positive panel and vice versa. The ease of use of the panels and readability of the instructions for use (IFU) were evaluated. Of species represented in the MicroScan database, 94.6% (185/195) of Gram-negative and 85.9% (110/128) of Gram-positive isolates were correctly identified up to species level. Of species not represented in the database (e.g., Streptococcus suis and Bacillus spp.), 53.1% out of 49 isolates were incorrectly identified as non-related bacterial species. Testing of Gram-positive isolates on Gram-negative panels and vice versa (n = 144) resulted in incorrect identifications for 38.2% of tested isolates. The readability level of the IFU was considered too high for LRS. Inoculation of the panels was favorably evaluated, whereas the visual reading of the panels was considered error-prone. In conclusion, the accuracy of the MicroScan identification panels was excellent for Gram-negative species and good for Gram-positive species. Improvements in stability, robustness, and ease of use have been identified to assure adaptation to LRS constraints.

Entities:  

Keywords:  MicroScan identification system; bacterial identification; blood cultures; clinical bacteriology; low-resource settings

Year:  2021        PMID: 33669829     DOI: 10.3390/diagnostics11020349

Source DB:  PubMed          Journal:  Diagnostics (Basel)        ISSN: 2075-4418


  2 in total

1.  Comparison of Zinc Concentrations in the Broth of Commercial Automated Susceptibility Testing Devices (Vitek 2, MicroScan, BD Phoenix, and Sensititre).

Authors:  Tomefa E Asempa; Christian M Gill; Vindana Chibabhai; David P Nicolau
Journal:  Microbiol Spectr       Date:  2022-04-04

2.  Identification and Characterization of a New Serratia proteamaculans Strain That Naturally Produces Significant Amount of Extracellular Laccase.

Authors:  Nadia Sufdar Ali; Fang Huang; Wensheng Qin; Trent Chunzhong Yang
Journal:  Front Microbiol       Date:  2022-07-18       Impact factor: 6.064

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.