Jian Liu1, Jing Ping Wu1, Ning Wang2, Guang Han Li1, Xiu Hong Wang3, Ying Wang1, Min Zheng1, Bo Zhang1.
Abstract
Objective To explore the value of elastography strain ratio(SR)combined with breast ultrasound imaging reporting and data system(BI-RADS-US)in the differential diagnosis of breast nodules.Methods A total of 471 breast nodules(from 471 patients)were reclassified by SR combined with BI-RADS-US.With the pathology results as gold standard,the area under the receiver operating characteristic(ROC)curve(AUC)was employed to evaluate the diagnostic performance,and the sensitivity,specificity,and accuracy were compared between the combined method and BI-RADS-US.Results Among the 471 breast nodules,180 nodules were benign and 291 were malignant.The AUC of the combined method was statistically significantly higher than that of BI-RADS-US(0.798 vs. 0.730;Z= 2.583, P= 0.010).SR,BI-RADS-US,and the combined method for diagnosing breast nodules had the sensitivity of 86.6%,99.0%,and 96.6%,the specificity of 67.2%,47.2%,and 63.3%,and the accuracy of 79.2%,79.2%,and 83.9%,respectively.The combined method increased the specificity from 47.2%(BI-RADS-US)to 63.3%(χ 2=14.25,P < 0.001),and downgraded 57.5%(42/73)benign nodules of BI-RADS category 4A to category 3.Conclusions SR combined with BI-RADS-US can improve the diagnostic performance for breast nodules.Especially,it can improve the specificity,avoiding unnecessary biopsy of breast nodules.Entities:
Keywords: breast nodules; elastography; strain ratio; ultrasound
Mesh:
Year: 2021 PMID: 33663665 DOI: 10.3881/j.issn.1000-503X.12839
Source DB: PubMed Journal: Zhongguo Yi Xue Ke Xue Yuan Xue Bao ISSN: 1000-503X