Davide Castellano1, Andrea Boghi2, Luca Di Maggio2, Alessandro Rapellino2, Daniele Savio2. 1. Department of Interventional Radiology and Neuroradiology, San Giovanni Bosco Hospital, Piazza del Donatore di Sangue, 3, 10154, Turin, Italy. gufosag@gmail.com. 2. Department of Interventional Radiology and Neuroradiology, San Giovanni Bosco Hospital, Piazza del Donatore di Sangue, 3, 10154, Turin, Italy.
Abstract
BACKGROUND: Ovarian vein embolization in pelvic varicocele is usually obtained using nitinol coils. These devices can not be used in patients with proven nickel allergy. CASE PRESENTATION: Shape memory polymer is a new embolic material available to interventionalists. A patient presented with pelvic congestion syndrome requiring embolisation of the left ovarian vein. The target vessel consisted of two twisted branches, each 5-6 mm in diameter. The patient also had a known allergy to nickel. Considering the anatomy and allergy status, embolisation with polyurethane shape memory polymer vascular plugs was considered a good case strategy. The embolisation procedure was technically successful with the deployment of two shape memory polymer plugs into each of the two left ovarian vein branches. Follow-up magnetic resonance imaging at 4 months showed sustained occlusion of the treated vessels and the patient showed no signs of allergy to the implanted material. CONCLUSIONS: In conclusion, our case presented an opportunity to utilise a new embolic material and achieve a good outcome in a patient with an allergy that may have resulted in complications when using metallic implants.
BACKGROUND:Ovarian vein embolization in pelvic varicocele is usually obtained using nitinol coils. These devices can not be used in patients with proven nickelallergy. CASE PRESENTATION: Shape memory polymer is a new embolic material available to interventionalists. A patient presented with pelvic congestion syndrome requiring embolisation of the left ovarian vein. The target vessel consisted of two twisted branches, each 5-6 mm in diameter. The patient also had a known allergy to nickel. Considering the anatomy and allergy status, embolisation with polyurethane shape memory polymer vascular plugs was considered a good case strategy. The embolisation procedure was technically successful with the deployment of two shape memory polymer plugs into each of the two left ovarian vein branches. Follow-up magnetic resonance imaging at 4 months showed sustained occlusion of the treated vessels and the patient showed no signs of allergy to the implanted material. CONCLUSIONS: In conclusion, our case presented an opportunity to utilise a new embolic material and achieve a good outcome in a patient with an allergy that may have resulted in complications when using metallic implants.