Yuqi Tang1, Junjie Yao1. 1. Department of Biomedical Engineering, Duke University, Durham, NC, USA.
Abstract
BACKGROUND: Photoacoustic computed tomography (PACT) detects light-induced ultrasound (US) waves to reconstruct the optical absorption contrast of the biological tissues. Due to its relatively deep penetration (several centimeters in soft tissue), high spatial resolution, and inherent functional sensitivity, PACT has great potential for imaging mouse brains with endogenous and exogenous contrasts, which is of immense interest to the neuroscience community. However, conventional PACT either assumes homogenous optical fluence within the brain or uses a simplified attenuation model for optical fluence estimation. Both approaches underestimate the complexity of the fluence heterogeneity and can result in poor quantitative imaging accuracy. METHODS: To optimize the quantitative performance of PACT, we explore for the first time 3D Monte Carlo (MC) simulation to study the optical fluence distribution in a complete mouse brain model. We apply the MCX MC simulation package on a digital mouse (Digimouse) brain atlas that has complete anatomy information. To evaluate the impact of the brain vasculature on light delivery, we also incorporate the whole-brain vasculature in the Digimouse atlas. k-wave toolbox was used to investigate the effect of inhomogeneous illumination on the reconstructed images and chromophore concentration estimation. RESULTS: The simulation results clearly show that the optical fluence in the mouse brain is heterogeneous at the global level and can decrease by a factor of five with increasing depth. Moreover, the strong absorption and scattering of the brain vasculature also induce the fluence disturbance at the local level. CONCLUSIONS: Both global and local fluence heterogeneity contributes to the reduced quantitative accuracy of the reconstructed PACT images of mouse brain. Correcting the optical fluence distribution can improve the quantitative accuracy of PACT. 2021 Quantitative Imaging in Medicine and Surgery. All rights reserved.
BACKGROUND: Photoacoustic computed tomography (PACT) detects light-induced ultrasound (US) waves to reconstruct the optical absorption contrast of the biological tissues. Due to its relatively deep penetration (several centimeters in soft tissue), high spatial resolution, and inherent functional sensitivity, PACT has great potential for imaging mouse brains with endogenous and exogenous contrasts, which is of immense interest to the neuroscience community. However, conventional PACT either assumes homogenous optical fluence within the brain or uses a simplified attenuation model for optical fluence estimation. Both approaches underestimate the complexity of the fluence heterogeneity and can result in poor quantitative imaging accuracy. METHODS: To optimize the quantitative performance of PACT, we explore for the first time 3D Monte Carlo (MC) simulation to study the optical fluence distribution in a complete mouse brain model. We apply the MCX MC simulation package on a digital mouse (Digimouse) brain atlas that has complete anatomy information. To evaluate the impact of the brain vasculature on light delivery, we also incorporate the whole-brain vasculature in the Digimouse atlas. k-wave toolbox was used to investigate the effect of inhomogeneous illumination on the reconstructed images and chromophore concentration estimation. RESULTS: The simulation results clearly show that the optical fluence in the mouse brain is heterogeneous at the global level and can decrease by a factor of five with increasing depth. Moreover, the strong absorption and scattering of the brain vasculature also induce the fluence disturbance at the local level. CONCLUSIONS: Both global and local fluence heterogeneity contributes to the reduced quantitative accuracy of the reconstructed PACT images of mouse brain. Correcting the optical fluence distribution can improve the quantitative accuracy of PACT. 2021 Quantitative Imaging in Medicine and Surgery. All rights reserved.
Entities:
Keywords:
3D Monte Carlo simulation (3D MC simulation); Quantitative photoacoustic imaging; digital mouse brain; mouse brain imaging; optical fluence distribution; photoacoustic computed tomography (PACT); whole-brain vasculature
Authors: Mehdi Azimipour; Ryan Baumgartner; Yuming Liu; Steven L Jacques; Kevin Eliceiri; Ramin Pashaie Journal: J Biomed Opt Date: 2014 Impact factor: 3.170
Authors: Junjie Yao; Lidai Wang; Joon-Mo Yang; Konstantin I Maslov; Terence T W Wong; Lei Li; Chih-Hsien Huang; Jun Zou; Lihong V Wang Journal: Nat Methods Date: 2015-03-30 Impact factor: 28.547
Authors: Reza Golestani; Chao Wu; René A Tio; Clark J Zeebregts; Artiom D Petrov; Freek J Beekman; Rudi A J O Dierckx; Hendrikus H Boersma; Riemer H J A Slart Journal: Eur J Nucl Med Mol Imaging Date: 2010-01-13 Impact factor: 9.236
Authors: X Luís Deán-Ben; Gali Sela; Antonella Lauri; Moritz Kneipp; Vasilis Ntziachristos; Gil G Westmeyer; Shy Shoham; Daniel Razansky Journal: Light Sci Appl Date: 2016-12-02 Impact factor: 17.782