Literature DB >> 33654177

Computational fluid dynamics (CFD) simulation analysis on retinal gas cover rates using computational eye models.

Makoto Gozawa1, Yoshihiro Takamura2, Tomoe Aoki2, Kentaro Iwasaki2, Masaru Inatani2.   

Abstract

We investigated the change in the retinal gas cover rates due to intraocular gas volume and positions using computational eye models and demonstrated the appropriate position after pars plana vitrectomy (PPV) with gas tamponade for rhegmatogenous retinal detachments (RRDs). Computational fluid dynamic (CFD) software was used to calculate the retinal wall wettability of a computational pseudophakic eye models using fluid analysis. The model utilized different gas volumes from 10 to 90%, in increments of 10% to the vitreous cavity in the supine, sitting, lateral, prone with closed eyes, and prone positions. Then, the gas cover rates of the retina were measured in each quadrant. When breaks are limited to the inferior retina anterior to the equator or multiple breaks are observed in two or more quadrants anterior to the equator, supine position maintained 100% gas cover rates in all breaks for the longest duration compared with other positions. When breaks are limited to either superior, nasal, or temporal retina, sitting, lower temporal, and lower nasal position were maintained at 100% gas cover rates for the longest duration, respectively. Our results may contribute to better surgical outcomes of RRDs and a reduction in the duration of the postoperative prone position.

Entities:  

Mesh:

Year:  2021        PMID: 33654177      PMCID: PMC7925587          DOI: 10.1038/s41598-021-84574-2

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  24 in total

1.  Primary vitrectomy alone for repair of retinal detachments following cataract surgery.

Authors:  M A Speicher; A D Fu; J P Martin; M A von Fricken
Journal:  Retina       Date:  2000       Impact factor: 4.256

2.  Bilateral Ulnar nerve palsies: an unusual complication of posturing after macular hole surgery.

Authors:  A Salam; P Harrington; A Raj; A Babar
Journal:  Eye (Lond)       Date:  2004-01       Impact factor: 3.775

3.  Primary vitrectomy for pseudophakic retinal detachment.

Authors:  K U Bartz-Schmidt; B Kirchhof; K Heimann
Journal:  Br J Ophthalmol       Date:  1996-04       Impact factor: 4.638

4.  Rapid enhancement of retinal adhesion by laser photocoagulation.

Authors:  Y H Yoon; M F Marmor
Journal:  Ophthalmology       Date:  1988-10       Impact factor: 12.079

5.  Primary vitrectomy without scleral buckling for rhegmatogenous retinal detachment.

Authors:  H Heimann; N Bornfeld; W Friedrichs; H Helbig; U Kellner; A Korra; M H Foerster
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-09       Impact factor: 3.117

6.  Impact of postoperative positioning on the outcome of pars plana vitrectomy with gas tamponade for primary rhegmatogenous retinal detachment: comparison between supine and prone positioning.

Authors:  Keiko Otsuka; Hisanori Imai; Akiko Miki; Makoto Nakamura
Journal:  Acta Ophthalmol       Date:  2017-05-27       Impact factor: 3.761

7.  Proposed classification of posterior staphylomas based on analyses of eye shape by three-dimensional magnetic resonance imaging and wide-field fundus imaging.

Authors:  Kyoko Ohno-Matsui
Journal:  Ophthalmology       Date:  2014-05-09       Impact factor: 12.079

8.  Trends and factors related to outcomes for primary rhegmatogenous retinal detachment surgery in a large asian tertiary eye center.

Authors:  Chee Wai Wong; Wan Ling Wong; Ian Yew San Yeo; Boon Kwang Loh; Edmund Yick Mun Wong; Doric Wen Kuan Wong; Sze Guan Ong; Chong Lye Ang; Shu Yen Lee
Journal:  Retina       Date:  2014-04       Impact factor: 4.256

9.  Preoperative estimation of distance between retinal break and limbus with wide-field fundus imaging: Potential clinical utility for conventional scleral buckling.

Authors:  Keijiro Ishikawa; Ri-Ichiro Kohno; Eiichi Hasegawa; Shintaro Nakao; Shigeo Yoshida; Koh-Hei Sonoda
Journal:  PLoS One       Date:  2019-02-12       Impact factor: 3.240

10.  Relations between age, weight, refractive error and eye shape by computerized tomography in children.

Authors:  Ha Tae Song; Young Jun Kim; Soo Jung Lee; Yeon Sung Moon
Journal:  Korean J Ophthalmol       Date:  2007-09
View more
  2 in total

1.  Employing computational fluid dynamics technique for analyzing the PACK-1300XY with methanol and isopropanol mixture.

Authors:  Y Cao; H A Dhahad; A Khandakar; M E H Chowdury; M A Ayari; S M Alizadeh; B Vaferi
Journal:  Sci Rep       Date:  2022-04-21       Impact factor: 4.996

2.  Application of moving particle semi-implicit (MPS) method on retro-oil fluid using three-dimensional vitreous cavity models from magnetic resonance imaging.

Authors:  Makoto Gozawa; Naoki Watanabe; Kentaro Iwasaki; Yoshihiro Takamura; Masaru Inatani
Journal:  Sci Rep       Date:  2022-02-02       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.