Literature DB >> 33654149

Treatment of distal clavicle fracture of Neer type II with locking plate in combination with titanium cable under the guide.

Jun Wang1, Jie Guan2, Minbo Liu2, Yongfeng Cui2, Yuhang Zhang2.   

Abstract

To observe and compare the curative effect of a locking plate plus titanium cable under the Guide device and clavicular hook plate in the treatment of Neer type II distal clavicle fractures. A prospective cohort study was conducted to analyse the clinical data of 36 patients with distal clavicle fractures from January 2016 to January 2019. The results were analysed. According to the random number method, the patients were divided into two groups: the titanium cable group (fixed with a titanium cable in combination with a locking plate) and hook plate group (fixed with a clavicular hook plate only). Under the guidance of a special device (for which a patent was obtained), in the titanium cable group, the coracoclavicular ligament was fixed with tension reduction, and then the distal clavicular fracture was fixed with a locking plate. In the hook plate group, the distal clavicle fracture was fixed with a hook plate. The incision length, operation time, bleeding volume and VAS score before, 1 week after and 1 year after the operation were compared between the two groups. The effect of the operation was evaluated by the Constant-Murley score before and 1 year after the operation. X-ray films were taken 2 days, 3 months, half a year and 1 year after the operation to observe the reduction and healing of fractures. At the same time, complications were recorded. The amount of bleeding was the same in the two groups. The operation time in the hook plate group was relatively short, and the difference was statistically significant (P < 0.05). The VAS score in the titanium cable group was significantly lower than that in the hook plate group one year after the operation. The Constant-Murley score in the titanium cable group and hook plate group was significantly higher 1 year after the operation. The number of postoperative complications in the titanium cable group was significantly lower than that in the hook plate group. The treatment of Neer type II distal clavicle fractures with a titanium cable plus a locking plate has a good curative effect, few complications and good postoperative recovery and thus is worth popularizing.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33654149      PMCID: PMC7925515          DOI: 10.1038/s41598-021-84601-2

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  25 in total

1.  Outcomes and function of conoid ligament on the basis of postoperative radiographic findings of arthroscopic stabilization for the distal clavicle fractures.

Authors:  Katsumi Takase; Kengo Yamamoto
Journal:  Orthop Traumatol Surg Res       Date:  2019-03-12       Impact factor: 2.256

2.  Treatment of distal clavicle nonunion with and without bone grafting.

Authors:  Emmanuele Santolini; Marco Stella; Francesca Sanguineti; Lamberto Felli; Federico Santolini
Journal:  Injury       Date:  2018-12-03       Impact factor: 2.586

3.  Outcome of arthroscopy-assisted treatment for distal clavicle fractures.

Authors:  Yuta Mochizuki; Takao Kaneko; Keisuke Kawahara; Shinya Toyoda; Hiroyasu Ikegami; Yoshiro Musha
Journal:  Arch Orthop Trauma Surg       Date:  2019-06-17       Impact factor: 3.067

4.  Complications after arthroscopic coracoclavicular reconstruction using a single adjustable-loop-length suspensory fixation device in acute acromioclavicular joint dislocation.

Authors:  Sang-Jin Shin; Nam-Ki Kim
Journal:  Arthroscopy       Date:  2014-12-25       Impact factor: 4.772

5.  Morphological analysis of acromion and hook plate for the fixation of acromioclavicular joint dislocation.

Authors:  Jong Pil Yoon; Yeon Soo Lee; Geun Soo Song; Joo Han Oh
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-20       Impact factor: 4.342

6.  Comparison of Treatment of Acute Unstable Distal Clavicle Fractures Using Anatomical Locking Plates with Versus without Additional Suture Anchor Fixation.

Authors:  Jixing Fan; Yufu Zhang; Qiang Huang; Xieyuan Jiang; Liang He
Journal:  Med Sci Monit       Date:  2017-11-16

7.  Intraoperative and Postoperative Complications after Arthroscopic Coracoclavicular Stabilization.

Authors:  Tae Kang Lim; Whang Kyun Oh
Journal:  Clin Orthop Surg       Date:  2019-02-18

8.  Clavicle hook plate versus distal clavicle locking plate for Neer type II distal clavicle fractures.

Authors:  Liang Li; Tian-Yan Li; Peichao Jiang; Guizhen Lin; Hongxiao Wu; Xiaochuan Han; Xuezhong Yu
Journal:  J Orthop Surg Res       Date:  2019-12-30       Impact factor: 2.359

9.  Comparison of four different internal fixation methods in the treatment of distal clavicle fractures.

Authors:  Liang Li; Hongxiao Wu; Peichao Jiang; Xiaochuan Han; Shiyuan Chen; Xuezhong Yu
Journal:  Exp Ther Med       Date:  2019-11-22       Impact factor: 2.447

10.  Comparison of the efficacy of a distal clavicular locking plate with and without a suture anchor in the treatment of Neer IIb distal clavicle fractures.

Authors:  Hua Xu; Wen Jun Chen; Xiao Cheng Zhi; Shi Chang Chen
Journal:  BMC Musculoskelet Disord       Date:  2019-10-30       Impact factor: 2.362

View more
  2 in total

1.  Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients.

Authors:  Yao Li; Hongwei Zhang
Journal:  J Healthc Eng       Date:  2022-01-25       Impact factor: 2.682

2.  Treatment of unstable distal clavicle fractures (Neer type IIb): a modified system using a miniature locking plate with a single button.

Authors:  Hua Ying; Jihuan Wang; Yuehua Sun; Kerong Dai; Chao Yu; Fei Yang
Journal:  J Int Med Res       Date:  2021-06       Impact factor: 1.671

  2 in total