Literature DB >> 33652786

Non-Invasive Determination of Glucose Concentration Using a Near-Field Sensor.

Aleksandr Gorst1, Kseniya Zavyalova1, Aleksandr Mironchev1.   

Abstract

The article presents a model of a near-field sensor for non-invasive glucose monitoring. The sensor has a specific design and forms a rather extended near-field. Due to this, the high penetration of electromagnetic waves into highly absorbing media (biologic media) is achieved. It represents a combined slot antenna based on a flexible RO3003 substrate. Moreover, it is small and rather flat (25 mm in diameter, 0.76 mm thick). These circumstances are the distinguishing features of this sensor in comparison with microwave sensors of other designs. The article presents the results of numerical modeling and experimental verification of a near-field sensor. Furthermore, a phantom of human biological media (human hand) was created for experimentation. In the case of numerical modeling, the sensor is located close to the hand model. In a full-scale experiment, it is located close to the phantom of the human hand for the maximum interaction of the near-field with biological materials. As a result of a series of measurements for this sensor, the reflection coefficient is measured, and the dependences of the reflected signal on the frequency are plotted. According to the results of the experiments carried out, there is a clear difference in glucose concentrations. At the same time, the accuracy of determining the difference in glucose concentrations is high. The values of the amplitude of the reflected signal with a change in concentration differ by 0.5-0.8 dB. This sensor can be used for developing a non-invasive blood glucose measurement procedure.

Entities:  

Keywords:  combined slot antenna; diabetes; dielectric permeability; electromagnetic fields; glucose concentration; microwave sounding; near-field sensor; non-invasive measurements; sensor

Mesh:

Substances:

Year:  2021        PMID: 33652786      PMCID: PMC7996804          DOI: 10.3390/bios11030062

Source DB:  PubMed          Journal:  Biosensors (Basel)        ISSN: 2079-6374


  13 in total

1.  The future of diabetes technologies and therapeutics.

Authors:  Mike Jones; Julia M Harrison
Journal:  Diabetes Technol Ther       Date:  2002       Impact factor: 6.118

2.  First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system.

Authors:  A Caduff; E Hirt; Yu Feldman; Z Ali; L Heinemann
Journal:  Biosens Bioelectron       Date:  2003-11-30       Impact factor: 10.618

Review 3.  Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium.

Authors:  Omar S Khalil
Journal:  Diabetes Technol Ther       Date:  2004-10       Impact factor: 6.118

Review 4.  Spectroscopic and clinical aspects of noninvasive glucose measurements.

Authors:  O S Khalil
Journal:  Clin Chem       Date:  1999-02       Impact factor: 8.327

5.  Requirements for calibration in noninvasive glucose monitoring by Raman spectroscopy.

Authors:  Jan Lipson; Jeff Bernhardt; Ueyn Block; William R Freeman; Rudy Hofmeister; Maya Hristakeva; Thomas Lenosky; Robert McNamara; Danny Petrasek; David Veltkamp; Stephen Waydo
Journal:  J Diabetes Sci Technol       Date:  2009-03-01

6.  Millimeter-wave Adaptive Glucose Concentration Estimation with Complex-Valued Neural Networks.

Authors:  Shizhen Hu; Seko Nagae; Akira Hirose
Journal:  IEEE Trans Biomed Eng       Date:  2018-11-23       Impact factor: 4.538

7.  Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum.

Authors:  Suzanne Gebhart; Mark Faupel; Richard Fowler; Candis Kapsner; Daniel Lincoln; Valarie McGee; John Pasqua; Leigh Steed; Michael Wangsness; Fan Xu; Madeleine Vanstory
Journal:  Diabetes Technol Ther       Date:  2003       Impact factor: 6.118

8.  Optical coherence tomography-based continuous noninvasive glucose monitoring in patients with diabetes.

Authors:  Robert A Gabbay; Surendra Sivarajah
Journal:  Diabetes Technol Ther       Date:  2008-06       Impact factor: 6.118

9.  Impact of environmental temperature on skin thickness and microvascular blood flow in subjects with and without diabetes.

Authors:  T Forst; A Caduff; M Talary; M Weder; M Brändle; P Kann; F Flacke; Ch Friedrich; A Pfützner
Journal:  Diabetes Technol Ther       Date:  2006-02       Impact factor: 6.118

10.  Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry.

Authors:  Yoshihito Hayashi; Marc-Aurèle Brun; Kenzo Machida; Seungmin Lee; Aya Murata; Shinji Omori; Hidetoshi Uchiyama; Yoshinori Inoue; Toshifumi Kudo; Takahiro Toyofuku; Masayuki Nagasawa; Isao Uchimura; Tomomasa Nakamura; Takeshi Muneta
Journal:  Biorheology       Date:  2017       Impact factor: 1.875

View more
  2 in total

Review 1.  Commercial and Scientific Solutions for Blood Glucose Monitoring-A Review.

Authors:  Yirui Xue; Angelika S Thalmayer; Samuel Zeising; Georg Fischer; Maximilian Lübke
Journal:  Sensors (Basel)       Date:  2022-01-06       Impact factor: 3.576

2.  RF Remote Blood Glucose Sensor and a Microfluidic Vascular Phantom for Sensor Validation.

Authors:  Muhammad Farhan Affendi Mohamad Yunos; Rémi Manczak; Cyril Guines; Ahmad Fairuzabadi Mohd Mansor; Wing Cheung Mak; Sheroz Khan; Noor Amalina Ramli; Arnaud Pothier; Anis Nurashikin Nordin
Journal:  Biosensors (Basel)       Date:  2021-12-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.