Literature DB >> 33650570

The 1-Megapixel pnCCD detector for the Small Quantum Systems Instrument at the European XFEL: system and operation aspects.

Markus Kuster1, Karim Ahmed1, Kai Erik Ballak1, Cyril Danilevski1, Marko Ekmedžić1, Bruno Fernandes1, Patrick Gessler1, Robert Hartmann2, Steffen Hauf1, Peter Holl2, Michael Meyer1, Jacobo Montaño1, Astrid Münnich1, Yevheniy Ovcharenko1, Nils Rennhack1, Tonn Rüter1, Daniela Rupp3, Dieter Schlosser2, Kiana Setoodehnia1, Rüdiger Schmitt1, Lothar Strüder2, Rico Mayro P Tanyag3, Anatoli Ulmer4, Hazem Yousef1.   

Abstract

The X-ray free-electron lasers that became available during the last decade, like the European XFEL (EuXFEL), place high demands on their instrumentation. Especially at low photon energies below 1 keV, detectors with high sensitivity, and consequently low noise and high quantum efficiency, are required to enable facility users to fully exploit the scientific potential of the photon source. A 1-Megapixel pnCCD detector with a 1024 × 1024 pixel format has been installed and commissioned for imaging applications at the Nano-Sized Quantum System (NQS) station of the Small Quantum System (SQS) instrument at EuXFEL. The instrument is currently operating in the energy range between 0.5 and 3 keV and the NQS station is designed for investigations of the interaction of intense FEL pulses with clusters, nano-particles and small bio-molecules, by combining photo-ion and photo-electron spectroscopy with coherent diffraction imaging techniques. The core of the imaging detector is a pn-type charge coupled device (pnCCD) with a pixel pitch of 75 µm × 75 µm. Depending on the experimental scenario, the pnCCD enables imaging of single photons thanks to its very low electronic noise of 3 e- and high quantum efficiency. Here an overview on the EuXFEL pnCCD detector and the results from the commissioning and first user operation at the SQS experiment in June 2019 are presented. The detailed descriptions of the detector design and capabilities, its implementation at EuXFEL both mechanically and from the controls side as well as important data correction steps aim to provide useful background for users planning and analyzing experiments at EuXFEL and may serve as a benchmark for comparing and planning future endstations at other FELs. open access.

Entities:  

Keywords:  X-ray CCD; X-ray detector; free-electron laser; photon detection; pnCCD

Year:  2021        PMID: 33650570      PMCID: PMC7941295          DOI: 10.1107/S1600577520015659

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  4 in total

1.  Development of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments.

Authors:  Takashi Kameshima; Shun Ono; Togo Kudo; Kyosuke Ozaki; Yoichi Kirihara; Kazuo Kobayashi; Yuichi Inubushi; Makina Yabashi; Toshio Horigome; Andrew Holland; Karen Holland; David Burt; Hajime Murao; Takaki Hatsui
Journal:  Rev Sci Instrum       Date:  2014-03       Impact factor: 1.523

2.  The Karabo distributed control system.

Authors:  Steffen Hauf; Burkhard Heisen; Steve Aplin; Marijan Beg; Martin Bergemann; Valerii Bondar; Djelloul Boukhelef; Cyril Danilevsky; Wajid Ehsan; Sergey Essenov; Riccardo Fabbri; Gero Flucke; Daniel Fulla Marsa; Dennis Göries; Gabriele Giovanetti; David Hickin; Tobiasz Jarosiewicz; Ebad Kamil; Dmitry Khakhulin; Anna Klimovskaia; Thomas Kluyver; Yury Kirienko; Manuela Kuhn; Luis Maia; Denys Mamchyk; Valerio Mariani; Leonce Mekinda; Thomas Michelat; Astrid Münnich; Anna Padee; Andrea Parenti; Hugo Santos; Alessandro Silenzi; Martin Teichmann; Kerstin Weger; John Wiggins; Krzysztof Wrona; Chen Xu; Christopher Youngman; Jun Zhu; Hans Fangohr; Sandor Brockhauser
Journal:  J Synchrotron Radiat       Date:  2019-08-09       Impact factor: 2.616

Review 3.  X-ray imaging detectors for synchrotron and XFEL sources.

Authors:  Takaki Hatsui; Heinz Graafsma
Journal:  IUCrJ       Date:  2015-04-10       Impact factor: 4.769

4.  The Adaptive Gain Integrating Pixel Detector at the European XFEL.

Authors:  Aschkan Allahgholi; Julian Becker; Annette Delfs; Roberto Dinapoli; Peter Goettlicher; Dominic Greiffenberg; Beat Henrich; Helmut Hirsemann; Manuela Kuhn; Robert Klanner; Alexander Klyuev; Hans Krueger; Sabine Lange; Torsten Laurus; Alessandro Marras; Davide Mezza; Aldo Mozzanica; Magdalena Niemann; Jennifer Poehlsen; Joern Schwandt; Igor Sheviakov; Xintian Shi; Sergej Smoljanin; Lothar Steffen; Jolanta Sztuk-Dambietz; Ulrich Trunk; Qingqing Xia; Mourad Zeribi; Jiaguo Zhang; Manfred Zimmer; Bernd Schmitt; Heinz Graafsma
Journal:  J Synchrotron Radiat       Date:  2019-01-01       Impact factor: 2.616

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.