Literature DB >> 3364361

Arterial distensibility and ambulatory blood pressure monitoring in essential hypertension.

R G Asmar1, P C Brunel, B M Pannier, P J Lacolley, M E Safar.   

Abstract

Arterial distensibility estimated by carotid femoral pulse wave velocity was evaluated in 22 patients with sustained essential hypertension, together with 3 different methods of blood pressure (BP) measurement: mercury sphygmomanometer, semiautomatic BP recording using the Dinamap apparatus and 24-hour ambulatory BP monitoring using a Spacelabs monitor. Although pulse wave velocity did not correlate with BP measured by mercury sphygmomanometer, it strongly and positively correlated with BP measurements using the other 2 procedures. The best correlation was observed with ambulatory BP with respect to systolic BP only (r = 0.685, p less than 0.001). Since cardiovascular morbidity and mortality in hypertensive patients is mainly related to lesions of the large arteries, the determination of pulse wave velocity together with ambulatory BP measurements is proposed for the evaluation of cardiovascular risk.

Entities:  

Mesh:

Year:  1988        PMID: 3364361     DOI: 10.1016/0002-9149(88)90127-0

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  11 in total

1.  Blood pressure levels and variance assessed by ambulatory monitoring: optimal parameters.

Authors:  F E Yates; L A Benton
Journal:  Ann Biomed Eng       Date:  1990       Impact factor: 3.934

Review 2.  Monitoring vascular health beyond blood pressure.

Authors:  Daniel A Duprez; Jay N Cohn
Journal:  Curr Hypertens Rep       Date:  2006-08       Impact factor: 5.369

3.  White-Coat and Reverse White-Coat Effects Correlate with 24-h Pulse Pressure and Systolic Blood Pressure Variability in Children and Young Adults.

Authors:  Hisayo Fujita; Seiji Matsuoka; Midori Awazu
Journal:  Pediatr Cardiol       Date:  2015-10-20       Impact factor: 1.655

4.  Arterial stiffness variations by gender in African-American and Caucasian children.

Authors:  WayWay M Hlaing; Ronald J Prineas
Journal:  J Natl Med Assoc       Date:  2006-02       Impact factor: 1.798

Review 5.  Circadian changes in blood pressure and their relationships to the development of microalbuminuria in type 1 diabetic patients.

Authors:  Donn Hogan; Empar Lurbe; M Reza Salabat; Josep Redon; Daniel Batlle
Journal:  Curr Diab Rep       Date:  2002-12       Impact factor: 4.810

6.  Arterial distensibility in children and teenagers: normal evolution and the effect of childhood vasculitis.

Authors:  Y F Cheung; P A Brogan; C B Pilla; M J Dillon; A N Redington
Journal:  Arch Dis Child       Date:  2002-10       Impact factor: 3.791

7.  Italian society of hypertension guidelines for conventional and automated blood pressure measurement in the office, at home and over 24 hours.

Authors:  Gianfranco Parati; Stefano Omboni; Paolo Palatini; Damiano Rizzoni; Grzegorz Bilo; Mariaconsuelo Valentini; Enrico Agabiti Rosei; Giuseppe Mancia
Journal:  High Blood Press Cardiovasc Prev       Date:  2013-01-22

8.  Ambulatory blood pressure monitoring in the elderly.

Authors:  Juan Diego Mediavilla García; Fernando Jaén Águila; Celia Fernández Torres; Blas Gil Extremera; Juan Jiménez Alonso
Journal:  Int J Hypertens       Date:  2011-12-20       Impact factor: 2.420

9.  Arterial stiffness in lower limb amputees.

Authors:  Pedro Magalhães; Daniel P Capingana; Amílcar B T Silva; Inês R Capunge; Mauer A A Gonçalves
Journal:  Clin Med Insights Circ Respir Pulm Med       Date:  2011-09-19

10.  Influences on the Functional Behavior of Great Arteries during Orthostasis.

Authors:  Jorge Elias Neto; Albano Ferreira; Guilherme Futuro; Luiz Carlos Dos Santos; Nevelton Heringer Filho; Fernando Gomes; Jose Geraldo Mill
Journal:  Arq Bras Cardiol       Date:  2019-12       Impact factor: 2.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.