Literature DB >> 33634207

Flash Brillouin Scattering: A Confocal Technique for Measuring Glass Transitions at High Scan Rates.

Konrad Rolle1, Hans-Jürgen Butt1, George Fytas1.   

Abstract

Glass transition temperatures T g are most commonly measured by differential scanning calorimetry, a method that has been extended to the flash scanning calorimetry (FSC) regime by reducing sample volumes. However, significant manual preparation effort can render FSC impractical for, e.g., local probing of spatially heterogeneous specimens. Another strategy can be to select a small volume by focusing down a laser beam, where Brillouin Light Scattering (BLS) is a proven method for confocal T g measurement. Here, we introduce Flash Brillouin Scattering, which extends BLS to fast scan rates, achieved by periodically heating the probed region with an infrared laser. For comparison with conventional BLS, we first characterize T g of pure glycerol, and show how rapid quenching produces a less packed glass with downshifted sound velocity. We then turn toward its aqueous solutions, which crystallize too fast for a nonflash approach, and demonstrate scan rates in excess of 105 K/s. These results are of interest not only because glycerol is a model system for hydrogen-bonded glass formers, but also because of its applications as a cryoprotectant for frozen biological samples. Light scattering studies of the latter, currently limited to cryo-Raman spectroscopy, are likely to be complemented by the technique introduced here.
© 2020 American Chemical Society.

Entities:  

Year:  2020        PMID: 33634207      PMCID: PMC7898954          DOI: 10.1021/acsphotonics.0c01533

Source DB:  PubMed          Journal:  ACS Photonics        ISSN: 2330-4022            Impact factor:   7.529


Several techniques exist for characterizing the glass transition temperature Tg, most of which, however, are limited to quasi-static scan (heating and cooling) rates. This not only belies the dynamic identity of any assigned Tg value, but becomes a definite obstacle once systems with high crystallization rates are to be investigated. Thus, differential scanning calorimetry (DSC), the most widely available Tg analysis method, has to be extensively modified for so-called “Flash Scanning Calorimetry” (FSC)[1] experiments: Due to finite thermal diffusion, small (typically, nanogram) sample volumes are required to achieve rapid quenching and flash heating of, e.g., semicrystalline polymers. This not only increases constraints on the sensor, manufactured with MEMS technology from fragile single-use silicon nitride membranes. It also has to be accompanied by a significant manual preparation effort, which involves cutting the specimen down to μm-dimensions and positioning it on the ∼100 nm thin substrate. As a result, if the measurement has to be repeated many times due to, for example, large statistical variations, or nondestructive in situ probing is the objective, an alternative to FSC is needed. Optical Tg measurement, by virtue of its noncontact character, was quick to achieve results on samples with extreme dimensions long before nanocalorimetry gained prominence. Ellipsometry is widely available and convenient for examining Tg in the specific case of ultrathin films on a glass substrate,[2,3] where Tg is deduced from a temperature-dependent change in differential film thickness. For more general cases, however, frequency-domain Brillouin Light Scattering (BLS)[4] is preferred, which is not limited to thin films or other sample geometries. While the context of these early studies were confinement effects on length scales less than 100 nm, we will aim to show here how the same technology can be repurposed for “flash” experiments for which FSC is ill-adapted. Indeed, by focusing down a laser beam with an appropriate objective lens, μm-sized volumes can easily be selected in BLS, akin to other confocal microscopy techniques. Though confocal Brillouin spectroscopy has seen a surge of interest over the past decade for mechanical bioimaging,[5,6] its potential utility for flash Tg determination has seemingly not been noticed yet. Compared with FSC, a confocal technique would be particularly advantageous for local probing or imaging of a structure with spatially heterogeneous Tg distribution, since several points on the same sample can easily be checked this way. A spatial Tg map can be constructed using atomic force microscopy (AFM), an approach that often goes by the name of local thermal analysis (LTA),[7,8] boasts resolution below 100 nm[9,10] and is commercially available.[11] Setting aside the question of how such a quasi-static Tg probe translates to high scan rates,[12] AFM is limited to probing the sample surface, with which contact has to be established. Hence, rather than polymers, we will concentrate on molecular liquids, using glycerol as a model glass former. Indeed, confocal microscopy is much better adapted for studying liquids than AFM, since the liquid can be enclosed in a transparent cell, while the exposed liquid/gas interface probed by AFM is susceptible to evaporation[13] (a drawback also of the open-air[14] FSC sensor). Furthermore, glycerol has widely featured not only in fundamental Tg studies, but is also of practical interest for applications as a cryoprotectant when freezing, e.g., embryos[15,16] or other biological material for preservation at liquid-nitrogen temperatures. Finally, by choosing glycerol, we can first validate our technique by comparing results with existing BLS data,[17] as measured by quasi-static methods. By adding water, we then produce an aqueous solution which, for compositions of typically less than 75 wt % glycerol (termed the “maximally freeze concentrated solution” or MFCS[18]) will crystallize if the quench is not sufficiently rapid. Hence, the mixed system cannot be examined by conventional BLS and requires a new method of Tg determination, to be introduced in this paper and referred to as “Flash Brillouin Scattering” (FBS) by analogy with FSC in what follows. BLS is an inelastic light scattering technique similar to Raman spectroscopy insofar as an incident laser beam interacts with vibrations (“phonons”). Resolving scattered light in a spectrometer then allows for deduction of vibration frequency and, hence, material properties. However, while Raman looks at individual molecular vibrations, BLS is sensitive to lower frequency GHz acoustic phonons (“sound waves”) from the collective motion of the solid, whence its main use for elasticity measurement. However, this also renders it superior to Raman[19−21] at detecting cooperative phenomena like the glass transition. Accordingly, it has been widely used for this purpose[22,23] as well as the related one of deducing GHz structural relaxation times from temperature scans for the frequency at which the hypersonic loss maximum (phonon lifetime minimum) occurs.[24] While for bioimaging applications a dispersive spectrometer design based on a prism called “virtually imaged phased array” (VIPA) is adopted,[25,5] only tentative steps[26] have been undertaken to exploit VIPA for Tg studies, which remain dominated by instruments based on scanning Fabry–Perot etalons. The latter, while significantly slower than VIPA because detectors are not multichannel, offer optimum frequency-resolution and contrast ratio, as well as proven[27] time-resolved measurement capabilities; both instrument variants can be easily[28,29] made to share the beam path with a Raman spectrometer. In the particular context of low-temperature biology, Raman has already established itself[30] as a tool for mapping cryoprotectant and ice distribution[31,32] and even for studying phase transitions.[33] Due to their technical similarity, we expect FBS to eventually come to extend the cryo-Raman toolbox, particularly if complementary low-temperature biology uses for BLS (e.g., strain sensing[34−36]) can be found.

Experimental Section

The BLS setup is based on a tandem-triple-pass Fabry–Perot (TFP) interferometer (JRS TFP-2HC) equipped with a narrow-linewidth laser (532 nm, 300 mW, Spectra-Physics Excelsior). Separation of the mirror pairs (etalons) inside the TFP is piezoelectrically scanned to analyze scattered light within a configurable frequency interval (free spectra range, FSR). In order to add time-resolved measurement capabilities, the manufacturer-provided one-dimensional multichannel analyzer (MCA) for spectrally resolving scattered light as a function of the scanning etalon position is replaced with a time-stamped MCA. The latter is custom-built from a programmable timer-counter board (NI PCIe-6612), similar to what can be found in photon correlation spectroscopy (PCS).[37] Two counters are set up for the scanning etalon and an external asynchronous reference signal, where the latter is incremented every 50 ns. The current counter tallies are saved each time the TFP photomultiplier tube (Hamamatsu H10682, 1.3 ns jitter, quantum efficiency 14%) registers a pulse, and each counter is reset by its respective control signal. MCA input is blocked by an RF-switch (Mini-Circuits ZYSWA-2–50DR+) during the central scan portion, when a shutter unit (JRS LM-2) rejects elastically (Rayleigh) scattered sample light. The obtained 2D-array can then be processed into a bidimensional histogram by MATLAB (see inset of MCA-frame in Figure ) with adjustable bin numbers (typical time-bin number up to 500), and Lorentzian fits (peak position given by red line in histogram plot) performed for the spectra corresponding to each time instant.
Figure 1

Flash Brillouin Scattering (FBS) setup with pure glycerol sample configuration in cryostat, comprising a polystyrene (PS) thin film. The thin green line represents the beam path of the visible (“532 nm”) probe-laser in backscattering configuration, showing microscope objective (“50×”, f = 4 mm), polarizers (“P”), half-waveplate (“λ/2”), beamsplitter (50:50), and a lens (f = 200 mm) with focal point on the spectrometer entrance pinhole. The thick red line represents the beam path for the amplified infrared (“1550 nm”) heating laser, with chopper and focusing asphere (f = 7.5 mm). A multichannel analyzer (MCA) registers chopper and scanning etalon (mirror) positions on each count from the photomultiplier tube (PMT), which are then processed into a bidimensional histogram (inset MCA-frame plot, showing central portion of 50 wt % case 2D-histogram for Ti = 123 K, with a thin red line marking Lorentzian peak position).

Flash Brillouin Scattering (FBS) setup with pure glycerol sample configuration in cryostat, comprising a polystyrene (PS) thin film. The thin green line represents the beam path of the visible (“532 nm”) probe-laser in backscattering configuration, showing microscope objective (“50×”, f = 4 mm), polarizers (“P”), half-waveplate (“λ/2”), beamsplitter (50:50), and a lens (f = 200 mm) with focal point on the spectrometer entrance pinhole. The thick red line represents the beam path for the amplified infrared (“1550 nm”) heating laser, with chopper and focusing asphere (f = 7.5 mm). A multichannel analyzer (MCA) registers chopper and scanning etalon (mirror) positions on each count from the photomultiplier tube (PMT), which are then processed into a bidimensional histogram (inset MCA-frame plot, showing central portion of 50 wt % case 2D-histogram for Ti = 123 K, with a thin red line marking Lorentzian peak position). For FBS, the external reference signal follows a periodic temperature cycle induced by heating pulses in the sample. In order to preserve the BLS advantages of noncontact, nondestructive, and high spatial resolution measurement, sample heating is accomplished by a second laser at 1550 nm, amplified to 1–2 W by an erbium-doped fiber amplifier (EDFA, civillaser.com). Heating pulses and their corresponding reference signal are then generated by a chopper (Thorlabs MC2000B) with an adjustable duty cycle blade (MC1F10A) set at 25%. This duty cycle is low enough to provide the system time to relax to its initial temperature, Ti. The latter is imposed by means of a Linkam (HFS 350EV-PB4) liquid nitrogen stage vertically mounted by a custom holder in the spectrometer, while the sample is pressed against the stage body by the spring-force of an L-shaped handle with magnetic base. Thermal contact is assured by a Panasonic pyrolitic graphite sheet, and air/nitrogen are blown across both front and back windows to prevent condensation. Two systems are investigated, pure glycerol and an aqueous mixture (50 wt %). For both, the sample consists in a drop of liquid sandwiched between two coverslips, separated by 2 μm ultrathin aluminum spacer foil (Alfa Aesar). For the aqueous mixture, the 1550 nm laser can heat the system under study directly, due to the proximity of its wavelength to the 1480 nm water absorption peak. For pure glycerol, absorption is low, so an additional ∼2 μm polystyrene (molecular weight MW = 200 kDa) thin film is spin-cast[38,39] from toluene solution to which a broadband infrared dye (Epolight 1125) has been added at less than 1 wt %. Also, for confining pure glycerol in the sample cell, the coverslips are preheated, which reduces glycerol viscosity and makes it easier to achieve the target thickness.[40] For both systems, overnight vacuum drying at 100 °C is used to remove any excess water prior to sample assembly; for the mixture, Milli-Q water is then readded to achieve the desired concentration. Finally, the stage is flooded with nitrogen atmosphere and the samples are cooled down to Ti = 123 K at the maximum rate of 30 K/min permitted by the cryostat. For the aqueous mixture, Ti = 88 K was also examined. Back scattering geometry, where incident and scattered light pass through a single objective (Nikon CFI T Plan Epi SLWD 50×), is used for the probe laser, polarizer orientations (see Figure ) being the same in both paths. The Linkam stage is orientated at 15° to avoid sending the reflection from the sample toward the spectrometer entrance; this reduces laser noise and thereby obviates the need for a cleanup filter (e.g., JRS TCF-1). FSRs were set to 25 and 40 GHz for pure and aqueous (50 wt %) glycerol systems, respectively. In the absence of an infrared objective,[41] the 1550 nm laser is focused normally through the Linkam front window (working distance <5 mm) by a separate aspheric lens with f = 7.5 mm (Thorlabs A375TM-C). In order to find the probe focus, the heating laser is scanned over the sample surface and the spectrum observed in real-time until the optimal position is reached. The chopper frequency is then set between 100 and 500 Hz with a view to maximizing the transient temperature rise contribution to the cycle, and the acquisition is run for some 3–6 h. Checks for any stability issues (alignment, cryostat failure, etc.) are conducted both during the experiment and on the final data file.

Results and Discussion

Comparison data from quasi-static BLS is only available for the higher viscosity system i.e. pure glycerol, which is hence the starting point for demonstrating FBS feasibility. The time-evolution of the Brillouin frequency-shift of glycerol (Figure a, with heating at 100 Hz chopper frequency and 25% duty cycle) is the basic quantity in FBS for deducing the temperature-dependent phonon frequency (and, hence, Tg). Considering film dimensions (∼2 μm) Brillouin scattering occurs from phonon modes of the bulk material, here associated with the longitudinal sound velocity; for thinner supported films, multiple reflections from surface and interface can form standing acoustic waves and the BLS spectrum consists of several interference controlled peaks.[42] Similar to conventional BLS at fixed temperature, the reported frequency values are then obtained from a Lorentzian representation of the glycerol phonon peak in the experimental spectra at fixed time. As mentioned, pure glycerol does not absorb at the heating wavelength of 1550 nm, so a spin-cast polystyrene (PS) film (Figure ) containing infrared dye is heated in its stead. Accordingly, it is necessary to distinguish the glycerol from the PS signal, and a double Lorentzian fit to the longitudinal phonon peaks of PS (lower) and glycerol (higher frequency) has to be performed. This is illustrated in the inset of Figure a, where spectra are recorded on the heating cycle, that is, the portion before the 4 ms mark. The glycerol phonon peak is seen to broaden and approach, but not cross, the more weakly temperature-dependent peak of the glassy PS.
Figure 2

FBS data for pure glycerol: (a) time-evolution of the glycerol frequency-shift in backscattering geometry, obtained from the Lorentzian representation of the BLS spectra; the inset shows selected spectra, sampled on the heating cycle (differential time interval for sampling Δt ∼ 0.07 ms) and displaying two phonon peaks assigned to polystyrene (PS, low frequency) and glycerol (high frequency); (b) time-evolution of PS peak area ∼IPS(t)/IPS(t0) and the two variables used for temperature calibration, PS frequency-shift fPS(t) (note negative frequencies) and integrated detector counts I(t)/I(t0), the latter due to both PS and glycerol inelastic scattering; identifying left- and right-hand y-axes, the differential frequency shift α for fPS(T) is deduced; (c) glycerol temperature calibrated using the frequency-shift fPS(T) from the PS thin film (see top right inset), with heating and cooling cycles distinguished by color for convenience; at high temperature, agreement of the heating cycle with reference data from quasi-static BLS (tilted crosses) is improved (upright crosses) by a linear transformation of the x-axis at fixed Ti, so that the glass point can be found from the intersection of the linear fits for regions above and below Tg (bottom left inset); (d) similar to (c), but with glycerol temperature calibrated using time-evolution of integrated detector counts I(t)/I(t0); legend applies to both (c) and (d).

FBS data for pure glycerol: (a) time-evolution of the glycerol frequency-shift in backscattering geometry, obtained from the Lorentzian representation of the BLS spectra; the inset shows selected spectra, sampled on the heating cycle (differential time interval for sampling Δt ∼ 0.07 ms) and displaying two phonon peaks assigned to polystyrene (PS, low frequency) and glycerol (high frequency); (b) time-evolution of PS peak area ∼IPS(t)/IPS(t0) and the two variables used for temperature calibration, PS frequency-shift fPS(t) (note negative frequencies) and integrated detector counts I(t)/I(t0), the latter due to both PS and glycerol inelastic scattering; identifying left- and right-hand y-axes, the differential frequency shift α for fPS(T) is deduced; (c) glycerol temperature calibrated using the frequency-shift fPS(T) from the PS thin film (see top right inset), with heating and cooling cycles distinguished by color for convenience; at high temperature, agreement of the heating cycle with reference data from quasi-static BLS (tilted crosses) is improved (upright crosses) by a linear transformation of the x-axis at fixed Ti, so that the glass point can be found from the intersection of the linear fits for regions above and below Tg (bottom left inset); (d) similar to (c), but with glycerol temperature calibrated using time-evolution of integrated detector counts I(t)/I(t0); legend applies to both (c) and (d). In order to extract Tg from this plot, the time variable has to be eliminated and replaced with temperature, yielding the temperature-dependent phonon frequency f(T). Hence, knowledge of not only the time-dependent Brillouin frequency-shift f(t), but also temperature time-evolution T(t) is necessary. There are several approaches to obtaining this information: Since the initial temperature T = T(t0) = 123 K is known and the behavior of f(t) at temperature above Tg in the equilibrium liquid is not expected to depend on scan rate, it might be tempting to fit a curve between T and the deduced maximum temperature values. Unfortunately, there does not seem to be an easy analytical formula for T(t). Indeed, some models[43] predict an indefinite temperature rise with square-root of time, and simulations of laser heating of water films have been shown to disagree[44] with experiment for higher powers. Experimentally, a number of time-resolved optical thermometry methods exist,[45] with fluorescent ones[44] being particularly popular and Raman-based ones[46,47] holding maybe the most long-term promise here. However, Brillouin spectrometry also offers options for temperature measurement,[48] based mainly on monitoring frequency-shift f(t) and intensity I(t). In order to determine T(t), we first use the Brillouin frequency-shift for temperature sensing, where the PS film provides a convenient additional phonon frequency fPS for reference. Indeed, for heating not exceeding Tg, amorphous polymers show a weak but linear temperature-dependence of the frequency, independent of scan rate; above Tg, sensitivity increases, but photomechanical ablation[49] can become an issue. Accordingly, we plot fPS(t) from the double-Lorentzian representation of the BLS spectra (inset of Figure a) to obtain a first temperature reference, which produces a time-evolution curve as in Figure b (green symbols). However, while f(t) of glycerol is monotonically decreasing, fPS(t) saturates in spite of rising temperature. The former, alongside increasing IPS(t) in Figure b (red broken line), indicates that PS temperature does rise concomitantly, so an explanation might be change of fPS(t) at high scan rate. In order to estimate T(t) from fPS(t), it is also necessary to know the PS frequency-shift temperature differential α, where fPS(T) = f0(1 – αT). In principle, the slope α is a material property but in practice values ranging from 3 × 10–4 K–1 to 8 × 10–4 K–1 have been reported[50,51] for the glassy state (<373 K). Hence, we only exploit the linearity of fPS in temperature and adjust the slope until glycerol frequencies at high temperature from FBS overlap with those from quasi-static BLS, while the known Ti controls the offset. The result can be seen in Figure c, where quasi-static BLS data points (upright pink crosses) reported in the temperature scale provided by the top x-axis with α = 3.6 × 10–4 K–1 (see next paragraph for bottom x-axis) achieve coincidence on the heating cycle at least (f0 = 15.8 GHz). Horizontal error bars are large, but the Tg “kink” is clearly in evidence and leads to a value of Tg = 191 K (inset to Figure c). While in good agreement with Tg = 187 K from quasi-static BLS,[17] the Tg upshift at high scan rate seems too low considering the large frequency difference between the quenched and nonquenched glasses measured by FBS and quasi-static BLS respectively. The lower sound velocity for the former is due to less dense packing (larger fraction of free volume),[52] a circumstance confirmed by previous[22] BLS studies of time-dependent material response to a shallow (2–5 K) temperature step. Time-evolution in these cases, however, occurred over several hours, while entirely different time-scales are accessed by FBS. Other than frequency-shift, tracking intensity of light scattered by an acoustic phonon can be a means of temperature calibration.[48] Due to linearity in kBT, intensity can be expected to show much higher temperature sensitivity than the ∼10% increase observed in Figure b for fPS. Moreover, while for the latter only fi = f(Ti) is known due to large uncertainty on α, for intensity we can conveniently assume I(T = 0 K) = 0, in addition to Ii = I(t0) = I(Ti); hence, T ≈ I(t) × (Ti/Ii), meaning that not only relative but also absolute temperature information is gained. On the other hand, intensity also depends on density ρ and isothermal compressibility, both of which are potentially functions of temperature. For the PS film at least (as, e.g., for silica glass[48]), high linearity can be assumed, and it is accordingly interesting to compare peak area from the Lorentzian representation (red broken line in Figure b), which corresponds to intensity IPS(t), with frequency-shift evolution. On the heating cycle, there is good agreement for lower temperatures, whereas a rapid drop-off not mirrored by the frequency-shift is in evidence for the quench. The reason may be the more homogeneous temperature distribution during heating, since the laser heats dye distributed throughout the depth of the polystyrene, and heat does not have to diffuse first through the film. Using typical thermal diffusivity values of D ∼ 10–7 m2/s,[53] we would however not expect the relevant diffusion time scales following formula w2/4D to much exceed the chosen histogram time-bin width (∼10 μs), for film thickness w = 2 μm at least. Finally, identifying frequency shift with I/I (right-hand axis of Figure b) translated to temperature as above, another estimate for α = 4.4 × 10–4 K–1 (f0 = 16.0 GHz) can be obtained, corresponding to the bottom x-axis in Figure c. This value, however, seems to underestimate the glycerol temperature rise, since quasi-static BLS data points (tilted crosses in Figure c) lie too far right of the FBS curve, and the corresponding Tg = 178 K is somewhat low. While temperature-calibration based on PS intensity has got a solid methodological foundation, the signal is rather noisy, presumably due to difficulties with the Lorentzian fit upon growing proximity of PS and glycerol phonons (Figure a). Hence, it is interesting to see if summing detector counts at each time instant can replace the need for the Lorentzian. For the sake of simplicity, we do not distinguish intensities of glycerol and PS, but integrate over both, heuristically neglecting any potentially nonlinear behavior of the former in temperature. The result is shown as a solid blue line in Figure b: On the heating flank, detector counts I(t) match the PS reference intensity IPS(t) surprisingly well, though again there are deviations on the cooling cycle. In contrast to what we saw for fPS(t) (Figure c), this good correspondence concerns not only shape, but also dimensionless I/Ii values reported on the right-hand axis of Figure c. Trivially, a temperature estimate is then obtained from (I/Ii) × Ti and leads to the bottom x-axis calibration in Figure d. Alternatively, and as before, we can also impose agreement with quasi-static BLS data (crosses) of glycerol for higher temperatures, which leads to the top x-axis calibration (tilted crosses refer to bottom x-axis, upright crosses to top x-axis). For the latter, there is clearly a zone of good agreement close to Tg, though further out, the detector count calibration method seems to overestimate temperatures (again, only the heating cycle is considered). A reason might be overall change in sample optical properties that affect scattered light transmission. From the zone of good agreement, our Tg estimate is Tg = 200 K, which is higher than the literature value (Tg = 187 K as above) for quasi-static BLS, but compatible with the expected influence of quench rate due the low fragility[54] of glycerol (Tg = 185 K from the bottom x-axis in Figure d). The pure glycerol case is useful for demonstrating FBS feasibility and to establish the procedure of temperature calibration. More interesting, however, is the case of the aqueous glycerol solution (50 wt %, equivalently 15 mol % or 5.5 M), which cannot be measured at low temperature by conventional BLS. This is a widely studied[55,56] but not trivial system. Indeed, a particular difficulty often arises from spatial heterogeneity in glycerol distribution,[31] control of which was outside the scope of the present experiment. The procedure is similar to that for the pure glycerol, with two adaptations: First, to obviate need for the double Lorenztian, the PS film is removed, since the 1550 nm laser can now heat the system under study directly. In order to have a reference against which to check that aqueous glycerol solution intensity still gives a good calibration variable, the FSR is widened to 40 GHz. This allows for the glass substrate longitudinal phonon to be observed, which replaces PS as intensity-based reference thermometer. Second, due to spatial heterogeneity, high temperature results from quasi-static BLS (which, involving the liquid state, present a spatial average) can no longer be expected to necessarily correspond with those from FBS. However, as we have seen (crosses in Figure d), absolute temperatures from (I/Ii) × Ti are not always reliable, so a means of counterchecking is desirable. To this end, the same measurement is run twice in a row, with two different initial temperatures Ti = 88 and 123 K set on the cryostat. With offsets fixed by the two known Ti, we can then expect the two curves to coincide at high temperatures, for correctly calibrated slopes. Figure a shows the time-evolution of the Brillouin frequency-shift f(t) for the glycerol/water (50 wt %) mixture, considering both initial temperatures. Chopper frequency (Figure a,b) was slightly increased for the FBS run at Ti = 123 K, in order to allow for higher resolution sampling. Representative spectra (heating cycle for Ti = 88 K) are shown in the inset and represented by a single Lorentzian line (in view of broad spectra at intermediate times, to be discussed further below, a double Lorentzian fit was also attempted but not found to more consistently capture the shape deformation, which might additionally be influenced by Mie scattering); the glass substrate phonon at frequencies higher than 30 GHz was excluded from the fit. Time-evolution of integrated counts from aqueous glycerol I(t), intended for use as the time-resolved temperature probe, is shown (blue and red lines) in Figure b, and compared with results from the reference peak (green lines). The latter is now provided by the glass substrate integrated counts (peak above 30 GHz) rather than the PS fit, but its density ρ and compressibility can be expected to be at least as constant with temperature as for the glassy polymer. Shape-wise and for Ti = 88 K, there is good agreement; for T = 123 K, glass substrate final temperature Tf seems too close to Tf of the Ti = 88 K case considering 35 K difference in their Ti, but temperatures from aqueous glycerol overestimate T, far from Tg. In contrast to what we did for Figure b, however, this comparison only concerns normalized values I/Ii for the glass substrate, to which the two temperature rise values ΔT = Tf – Ti for the aqueous glycerol curves are then matched. Though ΔT(Ti = 88 K) = 227 K, but ΔT(Ti = 123 K) ∼ 260 K, which might be, for example, due to temperature-dependent absorption at 1550 nm or transmission at 532 nm, low-temperature behavior is reasonably robust to uncertainties on Tf. Thus, convincing agreement in the vicinity of Tg is obtained in spite of the large uncertainties of density ρ and sound velocity further out. Considering only the heating cycle, elimination of the time-variable thus leads to traces of phonon frequency against temperature f(T) for the two Ti, as in Figure c. As stated above, spatial microheterogeneity renders any comparison with quasi-static BLS dubitable even where data points for the latter (crosses in Figure c) pertain to temperatures above the melting point of ice. Nevertheless, confirmation of the technique can be obtained by comparing the curves from two different Ti. At high temperature, the two ΔT chosen above produce convincing correspondence, while at low temperatures, behavior is clearly different regarding slope, even though they intersect near the same Tg (inset to Figure c). Along with the bumpiness of the f(T) curve for T = 88 K in the sub-Tg region, this might hint at the existence of a kinetic process allowing for structural changes even in the glassy state, as reported[57] for phase change materials, likewise a class of systems with high crystallization rates. Another hypothesis might be that heating to lower Tf for Ti = 88 K allows a greater fraction of ice to remain, resulting in lower plasticization by water.
Figure 3

Representative FBS data for aqueous (50 wt %) glycerol: (a) time-evolution of the phonon frequency f(t), for both Ti = 88 (blue, 100 Hz) and 123 K (red, 250 Hz), obtained from the Lorentzian representation of the BLS spectra; inset: selected spectra (Ti = 88 K), sampled on the heating cycle (Δt = 0.02 ms); (b) time-evolution of temperatures deduced from integrated detector counts I(t), for both the glass substrate according to (I/Ii) × Ti (in green) and the glycerol/water mixture according to the formula on the left-hand y-axis (in blue and red), with ΔT(Ti) for the latter matched to glass substrate temperatures; (c) frequency-shift f(T) of glycerol/water mixture against temperature, calibrated using temperatures from (b), for Ti = 88 K (blue) and Ti = 123 K (red); reasonable agreement with quasi-static BLS points (crosses) above the melting point, but somewhat low Tg = 161 K (upper right inset, showing Ti = 123 K case) are found; (d) similar to (c), but showing line width Δf on the y-axis, with the inset illustrating how direction of incident light (thick green line) is randomized (and, hence, line width broadened) through scattering by ice nanocrystals.

Representative FBS data for aqueous (50 wt %) glycerol: (a) time-evolution of the phonon frequency f(t), for both Ti = 88 (blue, 100 Hz) and 123 K (red, 250 Hz), obtained from the Lorentzian representation of the BLS spectra; inset: selected spectra (Ti = 88 K), sampled on the heating cycle (Δt = 0.02 ms); (b) time-evolution of temperatures deduced from integrated detector counts I(t), for both the glass substrate according to (I/Ii) × Ti (in green) and the glycerol/water mixture according to the formula on the left-hand y-axis (in blue and red), with ΔT(Ti) for the latter matched to glass substrate temperatures; (c) frequency-shift f(T) of glycerol/water mixture against temperature, calibrated using temperatures from (b), for Ti = 88 K (blue) and Ti = 123 K (red); reasonable agreement with quasi-static BLS points (crosses) above the melting point, but somewhat low Tg = 161 K (upper right inset, showing Ti = 123 K case) are found; (d) similar to (c), but showing line width Δf on the y-axis, with the inset illustrating how direction of incident light (thick green line) is randomized (and, hence, line width broadened) through scattering by ice nanocrystals. More numerically, from Figure c, below Tg, we find slopes α = 2.1 × 10–3 K–1 and 2.7 × 10–3 K–1 for Ti = 88 and 123 K, respectively; above Tg, the slope is 3.9 × 10–3 K–1 for both. While this seems huge compared to glassy pure glycerol (α = 2.8 × 10–4 K–1 in Figure d) or, for example, PS slopes as above, from ultrasonic data[58] we graphically estimate a slope of ∼2 × 10–3 K–1 for 68 mol %, above Tg (though ultrasonic behavior can be expected[59] to slightly deviate from hypersonic). This large disparity expressed in the values of α reflects the different H-bonded structures of the two systems. Alternatively, it might relate to plasticization effects also observed in diblock copolymers.[60] A greater cause of concern is the Tg value obtained: The “kink” (inset to Figure c) is around 161 K, but literature indicates a value of 170 K,[61,56,62] which should be independent of concentration for less than 60 wt % solutions. One possible origin might be to suppose that part of the water was able to crystallize out, leaving behind a higher concentration glycerol solution (e.g., the MFCS). Indeed, the quench rate of 30 K/min permitted by our cryostat is slightly below the reported[63] critical cooling rate for 50 wt % solution. This explanation could account for values Tg ∼ 160 K. Alternatively, the reason could simply be poor fit quality (larger error bars above Tg in Figure c) of the single Lorentzian model for some of the spectra (inset of Figure a), probably due to residual ice, which causes ill-defined laser incidence direction (inset of Figure d), as well as additional acoustic losses. Ice formation is somewhat surprising for 50 wt % glycerol because critical heating rate at this concentration is said to be around 103 K/s,[63] while our rates exceed 105 K/s. However, its presence is confirmed by a small high frequency shoulder around ∼20 GHz, which remains immobile and emerges from the much stronger main peak at high temperatures (in the intermediate region, it is not clearly resolved, whence preference of the single over the double Lorentzian fit). This frequency range is consistent with reported[64] low-temperature sound velocities of ∼4000 m/s for hexagonal ice crystals with sizes exceeding the effective medium phonon wavelength (∼180 nm). In this case, FBS operates as an elastic impedance contrast based imaging technique with submicrometer spatial resolution.[65] In part, however, this hypothesis on ice-crystal formation is also corroborated by the proximity to Tg of the hypersonic loss maximum (Figure d) seen at 200 K. The latter should not be confused with the typical structural relaxation driven loss peak, which would be expected around 250 K based on dielectric data.[66,56] Other than scattering laser light (inset of Figure d), ice crystals increase hypersonic attenuation in analogy to what has been reported[67] for concentrated colloid dispersions. This circumstance can possibly have a detrimental knock-on effect on axial spatial resolution at least, coupled to phonon lifetime as we just mentioned.[68] Above Tg but below the freezing point of water, the initially huge line width decreases again, maybe because of nanocrystal disappearance enabled by their depressed melting point at small size.[69] Otherwise, the nanocrystals might belong to a metastable ice precursor phase reported[70,71] for this temperature range. The resemblance of the step-like Δf shape (Figure d) to the f(T) curve between 100 and 125 K corroborates the notion of the presence of sufficient ice nanocrystals that can increase the hypersonic attenuation. The second increase of Δf above 150 K marks the glass transition temperature, sensed here via a change of the dynamic viscosity η at Tg following Δf ∼ η/ρ.

Conclusion

We have demonstrated “Flash Brillouin Scattering” (FBS), a new method for measuring the glass transition temperature at high scan rates, based on time-resolved Brillouin confocal microscopy and capable of high spatial resolution in situ probing. Proof-of-principle was accomplished by comparing results on pure glycerol with data from quasi-static Brillouin scattering. Temperature calibration was recognized to be the main challenge, but an easy if possibly not universally applicable method, based on integrating detector counts and exploiting the glass substrate as reference, was found to give credible results. Turning toward its aqueous mixture (50 wt %), feasibility of FBS could thus be proven notwithstanding various system-specific issues, to be attributed probably to its spatial heterogeneity and imprecise control. However, in the practical context where glycerol/water is often studied, namely, cryopreservation of biological material by vitrification, our Brillouin-spectroscopy based “flash Tg” method would likely be integrated into a Raman confocal microscope,[31] as already in use in the discipline. In this configuration, Raman data would allow for precise concentration knowledge and offer various additional thermometry options. On the Brillouin front as well, however, we hope that the present study will spur improvements in temperature-sensing capabilities, for example, by identifying materials with high frequency-shift differentials. Also, the main drawback of the current experiment with a Fabry–Perot interferometer (FPI) are very long acquisition times, incompatible with any potential imaging applications. Though in part to blame on FPI-parameters such as detector choice,[29] a factor of at least 50 could be gained[72] if a prism-type (“Virtually Imaged Phased Array”) spectrometer could be employed.[26] By minimizing laser flash exposure duration, the latter strategy would also allow for exploring systems where high scan rates can lead to photomechanical ablation, not an issue in the present study, but a concern with, e.g., polymer thin films.[49] Considering its out-of-the-box high temporal resolution and otherwise excellent performance, FPI-based FBS is however likely to remain the reference solution for the foreseeable future.
  40 in total

1.  Low-frequency Raman investigation of the liquid-glass transition in glycerol.

Authors: 
Journal:  Phys Rev B Condens Matter       Date:  1993-02-01

2.  Picosecond acoustic transmission measurements. II. Probing high frequency structural relaxation in supercooled glycerol.

Authors:  Rebecca M Slayton; Keith A Nelson
Journal:  J Chem Phys       Date:  2004-02-22       Impact factor: 3.488

3.  Does Brillouin light scattering probe the primary glass transition process at temperatures well above glass transition?

Authors:  P Voudouris; N Gomopoulos; A Le Grand; N Hadjichristidis; G Floudas; M D Ediger; G Fytas
Journal:  J Chem Phys       Date:  2010-02-21       Impact factor: 3.488

4.  Confocal Brillouin microscopy for three-dimensional mechanical imaging.

Authors:  Giuliano Scarcelli; Seok Hyun Yun
Journal:  Nat Photonics       Date:  2007-12-09       Impact factor: 38.771

5.  Melting the ice: on the relation between melting temperature and size for nanoscale ice crystals.

Authors:  Ding Pan; Li-Min Liu; Ben Slater; Angelos Michaelides; Enge Wang
Journal:  ACS Nano       Date:  2011-05-20       Impact factor: 15.881

6.  The puzzling first-order phase transition in water-glycerol mixtures.

Authors:  Ivan Popov; Anna Greenbaum Gutina; Alexei P Sokolov; Yuri Feldman
Journal:  Phys Chem Chem Phys       Date:  2015-06-23       Impact factor: 3.676

7.  Commercial counterboard for 10 ns software correlator for photon and fluorescence correlation spectroscopy.

Authors:  Matteo Molteni; Fabio Ferri
Journal:  Rev Sci Instrum       Date:  2016-11       Impact factor: 1.523

8.  Subcellular measurements of mechanical and chemical properties using dual Raman-Brillouin microspectroscopy.

Authors:  Zhaokai Meng; Sandra C Bustamante Lopez; Kenith E Meissner; Vladislav V Yakovlev
Journal:  J Biophotonics       Date:  2015-11-24       Impact factor: 3.207

9.  Raman spectroscopy reveals the lipid phase transition in preimplantation mouse embryos during freezing.

Authors:  K A Okotrub; S Y Amstislavsky; N V Surovtsev
Journal:  Arch Biochem Biophys       Date:  2017-10-06       Impact factor: 4.013

10.  Glass transition of aqueous solutions involving annealing-induced ice recrystallization resolves liquid-liquid transition puzzle of water.

Authors:  Li-Shan Zhao; Ze-Xian Cao; Qiang Wang
Journal:  Sci Rep       Date:  2015-10-27       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.