H J Völker-Dieben, C C Kok-van Alphen, G van Dorp, A van Leeuwen.
Abstract
In highly vascularized corneas the number of graft failures caused by irreversible rejections is higher than in non-or slightly vascularized corneas. The importance of antigen compatibility is demonstrated, especially in these 'high risk' cases. Ten highly vascularized corneas were grafted with HLA-matched donor material; only one reversible rejection was seen in this group. Nine non-or slightly vascularized corneas were grafted with donor material chosen a random. Retrospective HLA matching was performed. Three irreversible rejections were seen in this group. The number of HLA incompatibilities was high.Entities:
Mesh:
Substances:
Year: 1977 PMID: 336315 DOI: 10.1007/bf00171454