Francisco Javier Alvarez-Gutiérrez1, Ana Gómez-Bastero Fernández2, Juan Francisco Medina Gallardo1, Carlos Campo Sien3, Paula Rytilä4, Julio Delgado Romero5.
Abstract
OBJECTIVE: To study patient preference for and satisfaction with the Easyhaler® device and to assess ease of training and use of the inhaler in patients previously treated with a variety of dry powder inhalers (DPIs).Entities:
Keywords: adherence; asthma control; clinical outcomes; dry powder inhalers; inhaler devices; patient satisfaction
Year: 2021 PMID: 33628015 PMCID: PMC7897861 DOI: 10.2147/PPA.S295710
Source DB: PubMed Journal: Patient Prefer Adherence ISSN: 1177-889X Impact factor: 2.711
Demographic and Clinical Characteristics (N=502)
| Characteristics | |
|---|---|
| Sex (female) n (%) | 317 (63.1) |
| Age (yrs, mean ± SD) | 50.2±16.2 |
| Age at onset of asthma (yrs, mean ± SD) | 34.4±19.1 |
| Age at initiation of asthma therapy (n=494) (yrs, mean ± SD) | 39.9±17.2 |
| Lung function, n (%) | |
| FEV ≥80% predicted and PEF ≥80% personal best | 293 (58.4) |
| FEV <80% predicted or PEF <80% personal best | 159 (31.7) |
| FEV <60% predicted | 48 (9.6) |
| Unknown | 2 (0.4) |
| Smoking, n (%) | |
| Never smoker | 300 (59.8) |
| Former smoker | 143 (28.5) |
| Current smoker | 57 (11.4) |
| Unknown | 2 (0.4) |
| Patients with comorbidities, n (%) | 244(48.6) |
Abbreviations: FEV, forced expiratory volume; PEF, peak expiratory flow.
Easyhaler Training Evaluation, n (%)
| Total (n=502) | |
|---|---|
| Ease of training in the use of the Easyhaler device | |
| Very | 302 (60.2) |
| Fairly | 174 (34.7) |
| Somewhat | 20 (4.0) |
| Not very | 4 (0.8) |
| Hardly at all | 2 (0.4) |
| Training time | |
| <5 min | 423 (84.3) |
| 5–10 min | 74 (14.7) |
| 10–20 min | 5 (1.0) |
| >20 min | 0 |
| Need to repeat instructions (yes) | 153 (30.5) |
| Number of repetitions (more than once) | 78 (15.5) |
| Easyhaler instructions are clear and easy to understand (yes) | 478 (95.2) |
| Difficulty using Easyhaler device (yes) | 54 (10.8) |
| Critical mistakes in the Easyhaler inhalation technique * | 23 (4.6) |
Notes: *Critical mistakes with Easyhaler: The patient does not open the device, does not shake and prepare the device properly before inhaling, does not hold the device in the upright position with the mouthpiece down, exhales into the device, does not inhale as fully as possible, does not hold breath after inhaling.
FSI-10-Based Qualitative Evaluation of Easyhaler Training (n=485)
| Previous Inhaler, n (%) | Easyhaler, n (%) | P value | |
|---|---|---|---|
| 1. Was it easy to learn how to use the inhaler? | |||
| Very | 189 (39.0) | 297 (61.2) | <0.001 |
| Fairly | 183 (37.7) | 164 (33.8) | |
| Somewhat | 74 (15.3) | 18 (3.7) | |
| Not very | 30 (6.2) | 4 (0.8) | |
| Hardly at all | 9 (1.8) | 2 (0.4) | |
| 2. Was it easy to prepare the inhaler for use? | |||
| Very | 230 (47.4) | 296 (61.0) | <0.001 |
| Fairly | 170 (35.1) | 169 (34.8) | |
| Somewhat | 51 (10.5) | 15 (3.1) | |
| Not very | 21 (4.3) | 2 (0.4) | |
| Hardly at all | 13 (2.7) | 3 (0.6) | |
| 3. Was the inhaler easy to use? | |||
| Very | 242 (49.9) | 300 (61.9) | <0.001 |
| Fairly | 170 (35.1) | 169 (34.8) | |
| Somewhat | 50 (10.3) | 13 (2.7) | |
| Not very | 17 (3.5) | 2 (0.4) | |
| Hardly at all | 6 (1.2) | 1 (0.2) | |
| 4. Did the inhaler fit your lips comfortably? | |||
| Very | 213 (43.9) | 280 (57.7) | <0.001 |
| Fairly | 179 (36.9) | 183 (37.7) | |
| Somewhat | 59 (12.2) | 17 (3.5) | |
| Not very | 26 (5.4) | 3 (0.6) | |
| Hardly at all | 8 (1.6) | 2 (0.4) | |
| 5. Was it easy to use the inhaler in terms of size and weight? | |||
| Very | 221 (45.6) | 349 (72.0) | <0.001 |
| Fairly | 189 (39.0) | 128 (26.4) | |
| Somewhat | 46 (9.5) | 6 (1.2) | |
| Not very | 22 (4.5) | 0 | |
| Hardly at all | 7 (1.4) | 2 (0.4) | |
| 6. After using the inhaler, do you feel that you used it correctly? | |||
| Very | 174 (35.9) | 253 (52.2) | <0.001 |
| Fairly | 200 (41.2) | 193 (39.8) | |
| Somewhat | 67 (13.8) | 28 (5.8) | |
| Not very | 36 (7.4) | 6 (1.2) | |
| Hardly at all | 8 (1.6) | 5 (1.0) | |
| 7. Overall, considering your answers to the above questions, were you satisfied with the inhaler? | |||
| Very | 196 (40.4) | 265 (54.6) | <0.001 |
| Fairly | 204 (42.1) | 197 (40.6) | |
| Somewhat | 56 (11.5) | 20 (4.1) | |
| Not very | 25 (5.2) | 3 (0.6) | |
| Hardly at all | 4 (0.8) | 0 |
Abbreviation: FSI-10, 10-item Feeling of Satisfaction with Inhaler.
FSI-10 Parametric Quantitative Evaluation of Satisfaction with Previous or New Inhaler (n=485)
| Previous Inhaler | Easyhaler | P value * | |
|---|---|---|---|
| 1. Was it easy to learn how to use the inhaler? | 4.06±0.98 | 4.55±0.65 | <0.001 |
| 2. Was it easy to prepare the inhaler for use? | 4.20±0.98 | 4.55±0.64 | <0.001 |
| 3 .Was it easy to use the inhaler? | 4.29±0.88 | 4.58±0.59 | <0.001 |
| 4. Did the inhaler fit your lips comfortably? | 4.16±0.95 | 4.52±0.64 | <0.001 |
| 5. Was the inhaler easy to use the inhaler in terms of size and weight? | 4.23±0.90 | 4.69±0.54 | <0.001 |
| 6. After using the inhaler, do you feel that you used it correctly? | 4.02±0.97 | 4.41±0.75 | <0.001 |
| 7. Overall, considering your answers to the above questions, were you satisfied with the inhaler? | 4.16±0.88 | 4.49±0.61 | <0.001 |
| TOTAL FSI-10 SCORE | 29.12±5.15 | 31.8±3.24 | <0.001 |
Note: *Statistically significant values (paired-samples t test).
Factors Influencing the Test of Satisfaction (FSI-10 Questionnaire)
| n | Previous Inhaler | Easyhaler Device | |||
|---|---|---|---|---|---|
| Qualitative Variables | |||||
| Median (p25/p75) | p | Median (p25/p75) | p | ||
| Lung function | |||||
| FEV ≥80% predicted | 288 | 29.7±4.8 | 0.006 | 32.0±3.2 | 0.023 |
| FEV <80% predicted | 195 | 28.2±5.5 | 31.5±3.2 | ||
| Adherence level (TAI) | |||||
| Low | 211 | 28.0±5.2 | <0.001 | 31.8±3.5 | 0.121 |
| Moderate | 167 | 30.0±4.4 | 31.9±3.0 | ||
| High | 107 | 30.1±5.6 | 31.7±3.3 | ||
| Asthma severity | |||||
| Mild | 146 | 30 (26/34) | 0.882 | 32 (30/34) | 0.374 |
| Moderate | 248 | 29 (26/34) | 33 (30/35) | ||
| Severe | 91 | 31 (28/34) | 32 (29/35) | ||
| Asthma Control (GINA 2019 criteria) | |||||
| Good control | 184 | 31 (28/35) | <0.001 | 33 (29/35) | 0.654 |
| Partial/poor control | 301 | 29 (25/33) | 32 (30/34) | ||
| Maintenance inhaler | |||||
| Turbuhaler | 165 | 29 (25/33) | <0.001 | 33 (30/35) | 0.645 |
| Ellipta | 92 | 31 (27.5/34) | 32 (29/34) | ||
| Nexthaler | 82 | 31 (29/34) | 33 (29/35) | ||
| Accuhaler | 51 | 27 (24/30) | 33 (31/35) | ||
| Spiromax | 30 | 30 (26/34) | 32 (30/34) | ||
| Other | 45 | 31 (27/35) | 33 (30.5/35) | ||
Abbreviations: FEV, forced expiratory volume; TAI, Test of Adherence to Inhalers.
Figure 1Device preference according to a self-reported questionnaire (n = 485).
Patient Preference According to the Clinical Categories Used in the Study (N=482), n (%)
| Previous Inhaler Preferred | Easyhaler Preferred | p | |
|---|---|---|---|
| N | 74 (15.4) | 186 (38.6) | |
| Lung function | |||
| FEV ≥80% predicted | 52 (18.1) | 99 (34.4) | 0.013 |
| FEV <80% predicted | 22 (11.5) | 87 (45.3) | |
| Asthma control | |||
| Good control | 36 (19.6) | 55 (29.9) | 0.004 |
| Partial/poor control | 38 (12.8) | 131 (44.0) | |
| Maintenance inhaler | |||
| Turbuhaler | 20 (12.1) | 79 (47.9) | <0.001 |
| Ellipta | 18 (19.6) | 24 (26.1) | |
| Nexthaler | 21 (25.6) | 19 (23.2) | |
| Accuhaler | 2 (3.9) | 30 (58.8) | |
| Spiromax | 5 (16.7) | 12 (40.0) | |
| Otros | 6 (13.3) | 13 (28.9) | |
| Quantitative variables | |||
| FSI score of previous inhaler | 32 (28/34) | 27 (23/31) | <0.001 |
| FSI score of Easyhaler | 29 (28/32) | 33 (31/35) | <0.001 |
| Adherence (TAI score) with previous inhaler | 47.5 (45/50) | 45.5 (38/48) | <0.001 |
Figure 2Forest plot of the multivariate logistic regression analysis showing odds ratios with 95% confidence intervals of the impact on the patient´s preference of satisfaction score (FSI) for the previous inhaler, the FSI-10 score for the Easyhaler, and the adherence score (TAI) for the previous inhaler.