Literature DB >> 33620353

A novel electrochemical lung cancer biomarker cytokeratin 19 fragment antigen 21-1 immunosensor based on Si3N4/MoS2 incorporated MWCNTs and core-shell type magnetic nanoparticles.

Mehmet Lütfi Yola1, Necip Atar2, Nermin Özcan3.   

Abstract

Lung cancer is one of deadliest and most life threatening cancer types. Cytokeratin 19 fragment antigen 21-1 (CYFRA 21-1) is a significant biomarker for the diagnosis of non-small cell lung cancer (NSCLC). Due to these reasons, a novel electrochemical immunosensor based on a silicon nitride (Si3N4)-molybdenum disulfide (MoS2) composite on multi-walled carbon nanotubes (Si3N4/MoS2-MWCNTs) as an electrochemical sensor platform and core-shell type magnetic mesoporous silica nanoparticles@gold nanoparticles (MMSNs@AuNPs) as a signal amplifier was presented for CYFRA21-1 detection in this study. Capture antibody (Ab1) immobilization on a Si3N4/MoS2-MWCNT modified glassy carbon electrode (Si3N4/MoS2-MWCNTs/GCE) was firstly successfully performed by stable electrostatic/ionic interactions between the -NH2 groups of the capture antibody and the polar groups of Si3N4/MoS2. Then, specific antibody-antigen interactions between the electrochemical sensor platform and the signal amplifier formed a novel voltammetric CYFRA21-1 immunosensor. The prepared composite materials and electrochemical sensor surfaces were characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). A linearity range of 0.01-1.0 pg mL-1 and a low detection limit (LOD) of 2.00 fg mL-1 were also obtained for analytical applications. Thus, the proposed immunosensor based on Si3N4/MoS2-MWCNTs and MMSNs@AuNPs has great potential for medical diagnosis of lung cancer.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33620353     DOI: 10.1039/d1nr00244a

Source DB:  PubMed          Journal:  Nanoscale        ISSN: 2040-3364            Impact factor:   7.790


  5 in total

1.  Voltammetric immunoassay based on MWCNTs@Nd(OH)3-BSA-antibody platform for sensitive BSA detection.

Authors:  Slađana Đurđić; Miloš Ognjanović; Maja Krstić Ristivojević; Bratislav Antić; Tanja Ćirković Veličković; Jelena Mutić; Zoltán Kónya; Dalibor Stanković
Journal:  Mikrochim Acta       Date:  2022-10-18       Impact factor: 6.408

2.  Enzyme-Free Electrochemical Sensors for in situ Quantification of Reducing Sugars Based on Carboxylated Graphene-Carboxylated Multiwalled Carbon Nanotubes-Gold Nanoparticle-Modified Electrode.

Authors:  Ke Liu; Xiaodong Wang; Bin Luo; Cheng Wang; Peichen Hou; Hongtu Dong; Aixue Li; Chunjiang Zhao
Journal:  Front Plant Sci       Date:  2022-04-28       Impact factor: 6.627

Review 3.  Application of Nanomaterial Modified Aptamer-Based Electrochemical Sensor in Detection of Heavy Metal Ions.

Authors:  Zanlin Chen; Miaojia Xie; Fengguang Zhao; Shuangyan Han
Journal:  Foods       Date:  2022-05-12

Review 4.  Liquid Biopsy-Based Biosensors for MRD Detection and Treatment Monitoring in Non-Small Cell Lung Cancer (NSCLC).

Authors:  Parvaneh Sardarabadi; Amir Asri Kojabad; Davod Jafari; Cheng-Hsien Liu
Journal:  Biosensors (Basel)       Date:  2021-10-15

5.  The diagnostic significance of 64-slice spiral CT combined with serological CA19-9, Bcl-2, CYFRA21-1 detection in thoracic esophageal carcinoma.

Authors:  Junfei Hao; Wei Liu; Chunyan Zhao; Taiyu Xia
Journal:  Transl Cancer Res       Date:  2021-12       Impact factor: 1.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.