Literature DB >> 3361867

Current developments in non-invasive measurement of arterial blood pressure.

K Yamakoshi1, P Rolfe, C Murphy.   

Abstract

Two new types of non-invasive method for measuring arterial blood pressure recently developed by us are reviewed. Both of the methods are based on the characteristics of the pressure-volume relationship in the artery. One is the volume-oscillometric method; and the other is the volume-compensation method, based on the vascular unloading principle. Both methods employ photoelectric plethysmography for detection of arterial volume changes in the biological segment. The volume-oscillometric method can measure systolic and mean arterial pressure, and is applicable to long-term ambulatory monitoring. The volume-compensation method allows the beat-by-beat measurement of systolic and diastolic pressure and the recording of the pressure waveform continuously and non-invasively. This paper discusses the measurement principle and evaluates the accuracy of each method as compared with direct measurements. Preliminary descriptions of newly designed instruments based on these two methods, and a few examples of the indirect pressure recordings, are also described. The results obtained show that the non-invasive methods for measuring arterial pressure presented here appear promising for use not only in physiological studies, but also in clinical practice and research laboratories.

Mesh:

Year:  1988        PMID: 3361867     DOI: 10.1016/0141-5425(88)90088-x

Source DB:  PubMed          Journal:  J Biomed Eng        ISSN: 0141-5425


  6 in total

1.  Noninvasive measurement of aortic pressure waveform by ultrasound.

Authors:  H Watanabe; M Kawai; T Sibata; M Hara; H Furuhata; S Mochizuki
Journal:  Heart Vessels       Date:  1998       Impact factor: 2.037

2.  Ambulatory instrument for monitoring indirect beat-to-beat blood pressure in superficial temporal artery using volume-compensation method.

Authors:  S Tanaka; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1996-11       Impact factor: 2.602

Review 3.  Biosensors: a viable monitoring technology?

Authors:  S P Higson; P M Vadgama
Journal:  Med Biol Eng Comput       Date:  1994-11       Impact factor: 2.602

Review 4.  Noninvasive 24 hour ambulatory blood pressure monitoring: current status.

Authors:  A Stanton; E O'Brien
Journal:  Postgrad Med J       Date:  1993-04       Impact factor: 2.401

5.  Electrical admittance cuff for noninvasive and simultaneous measurement of haematocrit, arterial pressure and elasticity using volume-oscillometric method.

Authors:  K Yamakoshi; S Tanaka; H Shimazu
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

6.  Comparison of oxidative stress and inflammation induced by different intravenous iron sucrose similar preparations in a rat model.

Authors:  Jorge Eduardo Toblli; Gabriel Cao; Leda Oliveri; Margarita Angerosa
Journal:  Inflamm Allergy Drug Targets       Date:  2012-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.