Literature DB >> 33613304

The Hemodynamic Mechanism of FFR-Guided Coronary Artery Bypass Grafting.

Bao Li1, Boyan Mao1,2, Yue Feng1,3, Jincheng Liu1, Zhou Zhao4, Mengyao Duan2, Youjun Liu1.   

Abstract

Clinically, fractional flow reserve (FFR)-guided coronary artery bypass grafting (CABG) is more effective than CABG guided by coronary angiography alone. However, no scholars have explained the mechanism from the perspective of hemodynamics. Two patients were clinically selected; their angiography showed 70% coronary stenosis, and the FFRs were 0.7 (patient 1) and 0.95 (patient 2). The FFR non-invasive computational model of the two patients was constructed by a 0-3D coupled multiscaled model, in order to verify that the model can accurately calculate the FFR results. Virtual bypass surgery was performed on these two stenoses, and a CABG multiscaled model was constructed. The flow rate of the graft and the stenosis coronary artery, as well as the wall shear stress (WSS) and the oscillatory shear index (OSI) in the graft were calculated. The non-invasive calculation results of FFR are 0.67 and 0.91, which are close to the clinical results, which proves that our model is accurate. According to the CABG model, the flow ratios of the stenosis coronary artery to the graft of patient 1 and patient 2 were 0.12 and 0.42, respectively. The time-average wall shear stress (TAWSS) results of patient 1 and patient 2 grafts were 2.09 and 2.16 Pa, respectively, and WSS showed uniform distribution on the grafts. The OSI results of patients 1 and 2 grafts were 0.0375 and 0.1264, respectively, and a significantly high OSI region appeared at the anastomosis of patient 2. The FFR value of the stenosis should be considered when performing bypass surgery. When the stenosis of high FFR values is grafted, a high OSI region is created at the graft, especially at the anastomosis. In the long term, this can cause anastomotic blockage and graft failure.
Copyright © 2021 Li, Mao, Feng, Liu, Zhao, Duan and Liu.

Entities:  

Keywords:  coronary artery bypass grafting; fractional flow reserve; hemodynamics; lumped parameter model; multiscale model

Year:  2021        PMID: 33613304      PMCID: PMC7892768          DOI: 10.3389/fphys.2021.503687

Source DB:  PubMed          Journal:  Front Physiol        ISSN: 1664-042X            Impact factor:   4.566


  2 in total

1.  A Novel Method to Determine the Cause of Left Internal Mammary Artery Instant Non-Patency Based on Transit Time Flow Measurement.

Authors:  Boyan Mao; Yue Feng; Mengyao Duan; Yihang Dong; Gaoyang Li; Bao Li; Jincheng Liu; Yuting Guo; Minghui Wei; Zhou Zhao; Youjun Liu
Journal:  Front Physiol       Date:  2022-06-30       Impact factor: 4.755

2.  Self-Similar Functional Circuit Models of Arteries and Deterministic Fractal Operators: Theoretical Revelation for Biomimetic Materials.

Authors:  Gang Peng; Jianqiao Guo; Yajun Yin
Journal:  Int J Mol Sci       Date:  2021-11-29       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.