Literature DB >> 33605541

Three-dimensional shape-conformation performances of wound dressings tested in a robotic sacral pressure ulcer phantom.

Adi Lustig1, Amit Gefen1.   

Abstract

Effective exudate retention by dressings requires close and intimate dressing-wound contact, immediately and continuously after the dressing application. Any dressing-wound spaces may allow for build-up of non-retained fluids, causing exudate pooling which forms a favourable environment for pathogen growth. Maceration may follow if the pooled exudates spread to peri-wound skin. Dressings with a claimed 3D-shape-conformation technology are commercially available; however, their effectiveness in minimising dressing-wound gaps has never been scientifically investigated. We present a novel bioengineering methodology for testing the effectiveness of such 3D-shape-conformation dressings, using our recently reported robotic phantom system of a sacral pressure ulcer. By means of 3D laser scanning and bespoke software, we reconstructed dressing shapes after simulated use and calculated the goodness-of-fit between each dressing (swelled to near-saturation) and the corresponding wound geometry. Two dressing sizes (10 × 10 cm and 12.5 × 12.5 cm) and two wound depths (2.5 or 2 cm) were considered. All the tested dressings were far from reaching good contact with the (simulated) wounds: Approximately one-third of the wound volume and nearly half of the wound surface were not in contact with the swelled dressings. Our present findings question whether 3D-shape-conformation dressings are effective, by revealing their swelling behaviour which was previously unknown.
© 2021 The Authors. International Wound Journal published by Medicalhelplines.com Inc (3M) and John Wiley & Sons Ltd.

Entities:  

Keywords:  exudate pooling; fluid retention; laboratory model; swell testing; wound dressing

Year:  2021        PMID: 33605541     DOI: 10.1111/iwj.13569

Source DB:  PubMed          Journal:  Int Wound J        ISSN: 1742-4801            Impact factor:   3.315


  6 in total

1.  Microstructure and Biological Properties of Electrospun In Situ Polymerization of Polycaprolactone-Graft-Polyacrylic Acid Nanofibers and Its Composite Nanofiber Dressings.

Authors:  Yi-Jen Huang; Chien-Lin Huang; Ruo-Yu Lai; Cheng-Han Zhuang; Wei-Hao Chiu; Kun-Mu Lee
Journal:  Polymers (Basel)       Date:  2021-12-03       Impact factor: 4.329

2.  Fluid Handling Dynamics and Durability of Silver-Containing Gelling Fiber Dressings Tested in a Robotic Wound System.

Authors:  Aleksei Orlov; Adi Lustig; Angela Grigatti; Amit Gefen
Journal:  Adv Skin Wound Care       Date:  2022-06-01       Impact factor: 2.373

3.  The fluid handling performance of the curea P1 multipurpose dressing against superabsorbent and foam dressing technologies.

Authors:  Aleksei Orlov; Amit Gefen
Journal:  Int Wound J       Date:  2022-03-07       Impact factor: 3.099

Review 4.  The performance of gelling fibre wound dressings under clinically relevant robotic laboratory tests.

Authors:  Adi Lustig; Amit Gefen
Journal:  Int Wound J       Date:  2022-02-10       Impact factor: 3.099

5.  The potential of a canister-based single-use negative-pressure wound therapy system delivering a greater and continuous absolute pressure level to facilitate better surgical wound care.

Authors:  Aleksei Orlov; Amit Gefen
Journal:  Int Wound J       Date:  2022-01-20       Impact factor: 3.099

6.  Fluid management and strength postsimulated use of primary and secondary dressings for treating diabetic foot ulcers: Robotic phantom studies.

Authors:  Adi Lustig; Amit Gefen
Journal:  Int Wound J       Date:  2021-06-16       Impact factor: 3.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.