Literature DB >> 33602964

Simple low dose radiography allows precise lung volume assessment in mice.

Amara Khan1, Andrea Markus1, Thomas Rittmann2, Jonas Albers1,3, Frauke Alves1,3,4, Swen Hülsmann5, Christian Dullin6,7.   

Abstract

X-ray based lung function (XLF) as a planar method uses dramatically less X-ray dose than computed tomography (CT) but so far lacked the ability to relate its parameters to pulmonary air volume. The purpose of this study was to calibrate the functional constituents of XLF that are biomedically decipherable and directly comparable to that of micro-CT and whole-body plethysmography (WBP). Here, we developed a unique set-up for simultaneous assessment of lung function and volume using XLF, micro-CT and WBP on healthy mice. Our results reveal a strong correlation of lung volumes obtained from radiographic XLF and micro-CT and demonstrate that XLF is superior to WBP in sensitivity and precision to assess lung volumes. Importantly, XLF measurement uses only a fraction of the radiation dose and acquisition time required for CT. Therefore, the redefined XLF approach is a promising tool for preclinical longitudinal studies with a substantial potential of clinical translation.

Entities:  

Mesh:

Year:  2021        PMID: 33602964      PMCID: PMC7893164          DOI: 10.1038/s41598-021-83319-5

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  44 in total

1.  A barometric method for measuring ventilation in newborn infants.

Authors:  J E DRORBAUGH; W O FENN
Journal:  Pediatrics       Date:  1955-07       Impact factor: 7.124

2.  Discrepancies between pediatric laboratories in pulmonary function results from healthy children.

Authors:  James Paton; Caroline Beardsmore; Aidan Laverty; Caroline King; Cara Oliver; David Young; Janet Stocks
Journal:  Pediatr Pulmonol       Date:  2011-10-28

3.  Visualizing treatment delivery and deposition in mouse lungs using in vivo x-ray imaging.

Authors:  Regine Gradl; Martin Dierolf; Lin Yang; Lorenz Hehn; Benedikt Günther; Winfried Möller; David Kutschke; Tobias Stoeger; Bernhard Gleich; Klaus Achterhold; Martin Donnelley; Franz Pfeiffer; Otmar Schmid; Kaye Susannah Morgan
Journal:  J Control Release       Date:  2019-06-27       Impact factor: 9.776

4.  Noninvasive measurement of airway responsiveness in allergic mice using barometric plethysmography.

Authors:  E Hamelmann; J Schwarze; K Takeda; A Oshiba; G L Larsen; C G Irvin; E W Gelfand
Journal:  Am J Respir Crit Care Med       Date:  1997-09       Impact factor: 21.405

5.  A longitudinal evaluation of partial lung irradiation in mice by using a dedicated image-guided small animal irradiator.

Authors:  Patrick V Granton; Ludwig Dubois; Wouter van Elmpt; Stefan J van Hoof; Natasja G Lieuwes; Dirk De Ruysscher; Frank Verhaegen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-09-04       Impact factor: 7.038

6.  Longitudinal in vivo microcomputed tomography of mouse lungs: No evidence for radiotoxicity.

Authors:  Greetje Vande Velde; Ellen De Langhe; Jennifer Poelmans; Peter Bruyndonckx; Emiliano d'Agostino; Erik Verbeken; Ria Bogaerts; Rik Lories; Uwe Himmelreich
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2015-05-29       Impact factor: 5.464

7.  Pungent general anesthetics activate transient receptor potential-A1 to produce hyperalgesia and neurogenic bronchoconstriction.

Authors:  Helge Eilers; Fiore Cattaruzza; Romina Nassini; Serena Materazzi; Eunice Andre; Catherine Chu; Graeme S Cottrell; Mark Schumacher; Pierangelo Geppetti; Nigel W Bunnett
Journal:  Anesthesiology       Date:  2010-06       Impact factor: 7.892

8.  Longitudinal micro-CT as an outcome measure of interstitial lung disease in TNF-transgenic mice.

Authors:  Richard D Bell; Christopher Rudmann; Ronald W Wood; Edward M Schwarz; Homaira Rahimi
Journal:  PLoS One       Date:  2018-01-10       Impact factor: 3.240

9.  The impact of respiratory gating on improving volume measurement of murine lung tumors in micro-CT imaging.

Authors:  S J Blocker; M D Holbrook; Y M Mowery; D C Sullivan; C T Badea
Journal:  PLoS One       Date:  2020-02-25       Impact factor: 3.240

10.  Real-time in vivo imaging of regional lung function in a mouse model of cystic fibrosis on a laboratory X-ray source.

Authors:  Rhiannon P Murrie; Freda Werdiger; Martin Donnelley; Yu-Wei Lin; Richard P Carnibella; Chaminda R Samarage; Isaac Pinar; Melissa Preissner; Jiping Wang; Jian Li; Kaye S Morgan; David W Parsons; Stephen Dubsky; Andreas Fouras
Journal:  Sci Rep       Date:  2020-01-16       Impact factor: 4.379

View more
  2 in total

1.  Non-Invasive Optical Motion Tracking Allows Monitoring of Respiratory Dynamics in Dystrophin-Deficient Mice.

Authors:  Angelika Svetlove; Jonas Albers; Swen Hülsmann; Marietta Andrea Markus; Jana Zschüntzsch; Frauke Alves; Christian Dullin
Journal:  Cells       Date:  2022-03-07       Impact factor: 6.600

2.  Simultaneous assessment of lung morphology and respiratory motion in retrospectively gated in-vivo microCT of free breathing anesthetized mice.

Authors:  Christian Dullin; Angelika Svetlove; Jana Zschüntzsch; Frauke Alves
Journal:  Sci Rep       Date:  2022-08-02       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.