Literature DB >> 33599374

Modeling of kyphoplasty cement for accurate dose calculations.

Per H Halvorsen1, Navneeth Hariharan1, Zackary T Morelli1, Ileana N Iftimia1.   

Abstract

We have determined the optimal method for modeling kyphoplasty cement to enable accurate dose calculations in the Eclipse treatment planning system (TPS). The cement studied (Medtronic Kyphon HV-R®) consists of 30% Barium, 68% polymethylmethacrylate (PMMA), and 2% benzoyl peroxide, formulated to be radiopaque with kV imaging systems. Neither Barium nor PMMA have a high physical density, resulting in different interaction characteristics for megavoltage treatment beams compared to kV imaging systems. This can lead to significant calculation errors if density mapping is performed using a standard CT number to density curve. To properly characterize the cement for dose calculation, we 3D printed a hemi-cylindrical container to fit adjacent to a micro-chamber insert for an anthropomorphic phantom, and filled the container with Kyphon cement. We CT scanned the combination, modeled the cement with multiple material assignments in the TPS, designed plans with different field sizes and beam geometry for five photon modes, and measured the doses for all plans. All photon energies show significant error in calculated dose when the cement is modeled based on the CT number. Of the material assignments we evaluated, polytetrafluoroethylene (PTFE) showed the best overall agreement with measurement. Calculated and measured doses agree within 3.5% for a 340-degree arc technique (which averages transmission and scatter effects) with the Acuros XB algorithm and PTFE as the assigned material. To confirm that PTFE is a reasonable substitute for kyphoplasty cement, we performed measurements in a slab phantom using rectangular inserts of cement and PTFE, showing average agreement of all photon modes within 2%. Based on these findings, we conclude that the PTFE material assignment provides acceptable dose calculation accuracy for the AAA and Acuros XB photon algorithms in the Eclipse TPS. We recommend that the cement be delineated as a structure and assigned the PTFE material for accurate dose calculation.
© 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.

Entities:  

Keywords:  dose calculation; kyphoplasty cement

Mesh:

Year:  2021        PMID: 33599374      PMCID: PMC7984498          DOI: 10.1002/acm2.13174

Source DB:  PubMed          Journal:  J Appl Clin Med Phys        ISSN: 1526-9914            Impact factor:   2.102


  7 in total

1.  Kyphoplasty for vertebral compression fractures: 1-year clinical outcomes from a prospective study.

Authors:  Jean-Valéry C E Coumans; Mary-Kay Reinhardt; Isador H Lieberman
Journal:  J Neurosurg       Date:  2003-07       Impact factor: 5.115

2.  Sensitivity study for CT image use in Monte Carlo treatment planning.

Authors:  Frank Verhaegen; Slobodan Devic
Journal:  Phys Med Biol       Date:  2005-02-17       Impact factor: 3.609

Review 3.  Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning.

Authors:  Indrin J Chetty; Bruce Curran; Joanna E Cygler; John J DeMarco; Gary Ezzell; Bruce A Faddegon; Iwan Kawrakow; Paul J Keall; Helen Liu; C M Charlie Ma; D W O Rogers; Jan Seuntjens; Daryoush Sheikh-Bagheri; Jeffrey V Siebers
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

4.  Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations.

Authors:  K Bush; I M Gagne; S Zavgorodni; W Ansbacher; W Beckham
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

5.  Evaluation of dose calculation accuracy of treatment planning systems at hip prosthesis interfaces.

Authors:  David Paulu; Parham Alaei
Journal:  J Appl Clin Med Phys       Date:  2017-03-20       Impact factor: 2.102

6.  Relationship between dosimetric leaf gap and dose calculation errors for high definition multi-leaf collimators in radiotherapy.

Authors:  Jinkoo Kim; James S Han; An Ting Hsia; Shidong Li; Zhigang Xu; Samuel Ryu
Journal:  Phys Imaging Radiat Oncol       Date:  2018-02-20

7.  Optimization of tomotherapy treatment planning for patients with bilateral hip prostheses.

Authors:  David Chapman; Shaun Smith; Rob Barnett; Glenn Bauman; Slav Yartsev
Journal:  Radiat Oncol       Date:  2014-02-04       Impact factor: 3.481

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.