Literature DB >> 33594135

Monitoring blood potassium concentration in hemodialysis patients by quantifying T-wave morphology dynamics.

Flavio Palmieri1,2,3, Pedro Gomis4,5, Dina Ferreira6, José Esteban Ruiz7, Beatriz Bergasa7, Alba Martín-Yebra8,9, Hassaan A Bukhari8,9, Esther Pueyo8,9, Juan Pablo Martínez8,9, Julia Ramírez10, Pablo Laguna8,9.   

Abstract

We investigated the ability of time-warping-based ECG-derived markers of T-wave morphology changes in time ([Formula: see text]) and amplitude ([Formula: see text]), as well as their non-linear components ([Formula: see text] and [Formula: see text]), and the heart rate corrected counterpart ([Formula: see text]), to monitor potassium concentration ([Formula: see text]) changes ([Formula: see text]) in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD). We compared the performance of the proposed time-warping markers, together with other previously proposed [Formula: see text] markers, such as T-wave width ([Formula: see text]) and T-wave slope-to-amplitude ratio ([Formula: see text]), when computed from standard ECG leads as well as from principal component analysis (PCA)-based leads. 48-hour ECG recordings and a set of hourly-collected blood samples from 29 ESRD-HD patients were acquired. Values of [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text] and [Formula: see text] were calculated by comparing the morphology of the mean warped T-waves (MWTWs) derived at each hour along the HD with that from a reference MWTW, measured at the end of the HD. From the same MWTWs [Formula: see text] and [Formula: see text] were also extracted. Similarly, [Formula: see text] was calculated as the difference between the [Formula: see text] values at each hour and the [Formula: see text] reference level at the end of the HD session. We found that [Formula: see text] and [Formula: see text] showed higher correlation coefficients with [Formula: see text] than [Formula: see text]-Spearman's ([Formula: see text]) and Pearson's (r)-and [Formula: see text]-Spearman's ([Formula: see text])-in both SL and PCA approaches being the intra-patient median [Formula: see text] and [Formula: see text] in SL and [Formula: see text] and [Formula: see text] in PCA respectively. Our findings would point at [Formula: see text] and [Formula: see text] as the most suitable surrogate of [Formula: see text], suggesting that they could be potentially useful for non-invasive monitoring of ESRD-HD patients in hospital, as well as in ambulatory settings. Therefore, the tracking of T-wave morphology variations by means of time-warping analysis could improve continuous and remote [Formula: see text] monitoring of ESRD-HD patients and flagging risk of [Formula: see text]-related cardiovascular events.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33594135      PMCID: PMC7887245          DOI: 10.1038/s41598-021-82935-5

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  43 in total

1.  A wavelet-based ECG delineator: evaluation on standard databases.

Authors:  Juan Pablo Martínez; Rute Almeida; Salvador Olmos; Ana Paula Rocha; Pablo Laguna
Journal:  IEEE Trans Biomed Eng       Date:  2004-04       Impact factor: 4.538

2.  High prevalence of cardiac autonomic dysfunction and T-wave alternans in dialysis patients.

Authors:  Eric A Secemsky; Richard L Verrier; Gerald Cooke; Cybele Ghossein; Haris Subacius; Amin Manuchehry; Charles A Herzog; Rod Passman
Journal:  Heart Rhythm       Date:  2010-11-30       Impact factor: 6.343

3.  ECG diagnosis: hyperkalemia.

Authors:  Joel T Levis
Journal:  Perm J       Date:  2013

4.  Noninvasive potassium determination using a mathematically processed ECG: proof of concept for a novel "blood-less, blood test".

Authors:  John J Dillon; Christopher V DeSimone; Yehu Sapir; Virend K Somers; Jennifer L Dugan; Charles J Bruce; Michael J Ackerman; Samuel J Asirvatham; Bryan L Striemer; Jan Bukartyk; Christopher G Scott; Kevin E Bennet; Susan B Mikell; Dorothy J Ladewig; Emily J Gilles; Amir Geva; Dan Sadot; Paul A Friedman
Journal:  J Electrocardiol       Date:  2014-10-18       Impact factor: 1.438

5.  Characterization of T Wave Amplitude, Duration and Morphology Changes During Hemodialysis: Relationship With Serum Electrolyte Levels and Heart Rate.

Authors:  Hassaan A Bukhari; Flavio Palmieri; Julia Ramirez; Pablo Laguna; Jose Esteban Ruiz; Dina Ferreira; Mark Potse; Carlos Sanchez; Esther Pueyo
Journal:  IEEE Trans Biomed Eng       Date:  2021-07-16       Impact factor: 4.538

6.  ECG-based detection of body position changes in ischemia monitoring.

Authors:  José García; Magnus Aström; Javier Mendive; Pablo Laguna; Leif Sörnmo
Journal:  IEEE Trans Biomed Eng       Date:  2003-06       Impact factor: 4.538

Review 7.  Role of potassium currents in cardiac arrhythmias.

Authors:  Ursula Ravens; Elisabetta Cerbai
Journal:  Europace       Date:  2008-07-24       Impact factor: 5.214

8.  The relationship between serum potassium concentrations and electrocardiographic characteristics in 163,547 individuals from primary care.

Authors:  Maria Lukács Krogager; Kristian Kragholm; Regitze Kuhr Skals; Rikke Nørmark Mortensen; Christoffer Polcwiartek; Claus Graff; Jonas Bille Nielsen; Jørgen K Kanters; Anders Gaarsdal Holst; Peter Søgaard; Adrian Pietersen; Christian Torp-Pedersen; Steen Møller Hansen
Journal:  J Electrocardiol       Date:  2019-09-04       Impact factor: 1.438

9.  Which QT Correction Formulae to Use for QT Monitoring?

Authors:  Bert Vandenberk; Eline Vandael; Tomas Robyns; Joris Vandenberghe; Christophe Garweg; Veerle Foulon; Joris Ector; Rik Willems
Journal:  J Am Heart Assoc       Date:  2016-06-17       Impact factor: 5.501

10.  Quantitative Evaluation of the Relationship between T-Wave-Based Features and Serum Potassium Level in Real-World Clinical Practice.

Authors:  Dukyong Yoon; Hong Seok Lim; Jong Cheol Jeong; Tae Young Kim; Jung-Gu Choi; Jong-Hwan Jang; Eugene Jeong; Chan Min Park
Journal:  Biomed Res Int       Date:  2018-12-18       Impact factor: 3.411

View more
  3 in total

1.  System of integrating biosignals during hemodialysis: the CONTINUAL (Continuous mOnitoriNg viTal sIgN dUring hemodiALysis) registry.

Authors:  Seonmi Kim; Donghwan Yun; Soonil Kwon; So-Ryoung Lee; Kwangsoo Kim; Yong Chul Kim; Dong Ki Kim; Kook-Hwan Oh; Kwon Wook Joo; Hyung-Chul Lee; Chul-Woo Jung; Yon Su Kim; Seung Seok Han
Journal:  Kidney Res Clin Pract       Date:  2022-05-23

2.  Monitoring of Serum Potassium and Calcium Levels in End-Stage Renal Disease Patients by ECG Depolarization Morphology Analysis.

Authors:  Hassaan A Bukhari; Carlos Sánchez; José Esteban Ruiz; Mark Potse; Pablo Laguna; Esther Pueyo
Journal:  Sensors (Basel)       Date:  2022-04-12       Impact factor: 3.847

3.  Nonlinear T-Wave Time Warping-Based Sensing Model for Non-Invasive Personalised Blood Potassium Monitoring in Hemodialysis Patients: A Pilot Study.

Authors:  Flavio Palmieri; Pedro Gomis; José Esteban Ruiz; Dina Ferreira; Alba Martín-Yebra; Esther Pueyo; Juan Pablo Martínez; Julia Ramírez; Pablo Laguna
Journal:  Sensors (Basel)       Date:  2021-04-12       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.