Literature DB >> 33592693

Two SPRi biosensors for the determination of cathepsin S in blood plasma.

Lukasz Oldak1, Anna Sankiewicz2, Beata Żelazowska-Rutkowska3, Bogdan Cylwik3, Zenon Lukaszewski4, Marcin Skoczylas5, Ewa Gorodkiewicz6.   

Abstract

Cathepsin S is an emerging marker for ovarian cancer. Two 'analytically specific' SPRi biosensors for the determination of Cath S have been developed. The reception part of one of the biosensors consists of the rat monoclonal antibody specific for cathepsin S attached to the gold surface via covalent bonds with cysteamine linker, while the second biosensor consists of the inhibitor LY3000328 attached via hydrophobic interaction with the 1-octadecanothiol linker. Under optimized conditions, in terms of pH and receptor concentration, both biosensors have linear response ranges between LOQ (0.14 ng mL-1) and 2.5 ng mL-1, which is suitable for the determination of Cath S in blood plasma samples of ovarian cancer patients and healthy individuals, after corresponding dilution with 0.15 M PBS buffer. Precision and recoveries are quite acceptable: below 7% and 98-101% respectively for the biosensor with antibody, and below 12% and 101-103% for the biosensor with inhibitor. The biosensors were validated by the determination of Cath S in series of plasma from ovarian cancer patients and healthy volunteers using both biosensors and ELISA, giving Pearson coefficients close to 1. Plasma Cath S concentration can be used as an ovarian cancer marker, in view of the highly elevated concentrations detected.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Antibody; Array of measuring points; Cancer markers; Inhibitor LY3000328; Ovarian cancer

Mesh:

Substances:

Year:  2020        PMID: 33592693     DOI: 10.1016/j.talanta.2020.121900

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

Review 1.  Recent Advancements in Receptor Layer Engineering for Applications in SPR-Based Immunodiagnostics.

Authors:  Marcin Drozd; Sylwia Karoń; Elżbieta Malinowska
Journal:  Sensors (Basel)       Date:  2021-05-29       Impact factor: 3.576

2.  An Immunosensor for the Determination of Cathepsin S in Blood Plasma by Array SPRi-A Comparison of Analytical Properties of Silver-Gold and Pure Gold Chips.

Authors:  Pawel Falkowski; Piotr Mrozek; Zenon Lukaszewski; Lukasz Oldak; Ewa Gorodkiewicz
Journal:  Biosensors (Basel)       Date:  2021-08-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.