Alessandro DI Filippo1,2, Chiara Adembri3,2, Laura Paparella2, Clelia Esposito4, Lorenzo Tofani5, Ylenia Perez1, Ida DI Giacinto6, Massimo Micaglio2, Massimiliano Sorbello7. 1. Section of Anesthesiology and Intensive Care, Department of Health Sciences, University of Florence, Florence, Italy. 2. Careggi University Hospital, Florence, Italy. 3. Section of Anesthesiology and Intensive Care, Department of Health Sciences, University of Florence, Florence, Italy - chiara.adembri@unifi.it. 4. Department of Anesthesiology, Resuscitation and Postoperative Intensive Care, AORN Ospedali dei Colli, Naples, Italy. 5. Department of Neurosciences, Psychology, Drug Research and Child Health, University of Florence, Florence, Italy. 6. Department of Organ Failure and Transplantation, St.Orsola-Malpighi University Hospital, Bologna, Italy. 7. Anestesiology and Intensive Care Unit, Vittorio Emanuele San Marco University Hospital, Catania, Italy.
Abstract
BACKGROUND: Supraglottic airway devices (SADs) are precious tools for airway management in both routine and rescue situations; few studies have analyzed the risk factors for their difficult insertion. METHODS: The aim of this study was to identify the risk factors for difficult insertion for a specific SAD, the Laryngeal Mask Airway LMA-Supreme™ (LMAS). This was a prospective multicentric observational study on a cohort of Italian adult patients receiving general anesthesia for elective surgery. The possible causes of difficulty in LMAS placement (difficulty in insertion or unsatisfactory ventilation) were identified based on literature and on the opinion of international airway management experts. A dedicated datasheet was prepared to collect patients' data, including anthropometric-parameters and parameters for the prediction of difficult airway management, as well as technical choices for the use of LMAS. Data were analyzed to discover the risk factors for difficult LMAS placement and the association between each risk factor and the proportion of incorrect positioning was evaluated through the relative risk and its confidence interval. RESULTS: Four hundred thirty-two patients were enrolled; seventy required two or more attempts to insert the LMAS; nine required a change of strategy. At multivariate analysis, the following factors were significantly associated with difficult LMAS placement: Mallampati III-IV with either phonation or not; inter-incisor distance < 3 cm; reduced neck mobility; no administration of neuromuscular blocking agents (NMBAs). CONCLUSIONS: The alignment of the laryngeal and pharyngeal axes seems to facilitate the procedure, together with NMBA administration; on the contrary, Mallampati grade III-IV are associated with difficult LMAS placement.
BACKGROUND: Supraglottic airway devices (SADs) are precious tools for airway management in both routine and rescue situations; few studies have analyzed the risk factors for their difficult insertion. METHODS: The aim of this study was to identify the risk factors for difficult insertion for a specific SAD, the Laryngeal Mask Airway LMA-Supreme™ (LMAS). This was a prospective multicentric observational study on a cohort of Italian adult patients receiving general anesthesia for elective surgery. The possible causes of difficulty in LMAS placement (difficulty in insertion or unsatisfactory ventilation) were identified based on literature and on the opinion of international airway management experts. A dedicated datasheet was prepared to collect patients' data, including anthropometric-parameters and parameters for the prediction of difficult airway management, as well as technical choices for the use of LMAS. Data were analyzed to discover the risk factors for difficult LMAS placement and the association between each risk factor and the proportion of incorrect positioning was evaluated through the relative risk and its confidence interval. RESULTS: Four hundred thirty-two patients were enrolled; seventy required two or more attempts to insert the LMAS; nine required a change of strategy. At multivariate analysis, the following factors were significantly associated with difficult LMAS placement: Mallampati III-IV with either phonation or not; inter-incisor distance < 3 cm; reduced neck mobility; no administration of neuromuscular blocking agents (NMBAs). CONCLUSIONS: The alignment of the laryngeal and pharyngeal axes seems to facilitate the procedure, together with NMBA administration; on the contrary, Mallampati grade III-IV are associated with difficult LMAS placement.
Authors: J Adam Law; Laura V Duggan; Mathieu Asselin; Paul Baker; Edward Crosby; Andrew Downey; Orlando R Hung; George Kovacs; François Lemay; Rudiger Noppens; Matteo Parotto; Roanne Preston; Nick Sowers; Kathryn Sparrow; Timothy P Turkstra; David T Wong; Philip M Jones Journal: Can J Anaesth Date: 2021-06-08 Impact factor: 5.063